4-9
INM12006 – MOOM V3.0
Copyright Dairymaster 2015
4.2.2.1
Carrying out the Range Test
A range test must be carried out to confirm a sufficient signal exists around the
complex / pasture area to allow for data upload to the Base Station from the
Moo on the cows collar.
Note: When conducting a Moo Range test with a second Basestation on a
live farm be aware that existing tags on the farm may start to connect to this second
Basestation. In order to eliminate this use the existing farm Basestation to do the
range test or change the FarmID for the second Basestation and Range Tag.
The Green LED flashes on the Range Tag when the Base Station is in range.
The Red LED flashes while the Base Station is out of range. For further information
on conducting a range test please refer to section 7.1 Range Tag Test 7-1.
Figure 8 - MooMonitor Range Test Tag
Part No: 10401610
Figure 9 - Green LED will flash on when Range
Tag is in range of the base station
Figure 10 - Red LED will flash on when Range
Tag is in range of the base station