Installation Guide
RAIL287 | 99003834
RM4 LED Signals Rail
Tricolor Wayside Colorlight
10V Module Only
Voltage Range
8 to 16V DC
Input Voltage Range
10V DC
Current Draw
Minimum of 1.35 A
BEFORE YOU BEGIN
Read these instructions completely and carefully. If you prefer to have this Installation Instructions
document in other languages, visit our official website at: www.gecurrent.com/transportation
Prepare Electrical Wiring
Electrical Requirements
• Follow all National Electric Codes (NEC)
and local codes.
Operating Specifications
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Disconnect Before Servicing or installing product. The LED module must be installed into a signal head with adequate ingress
protection for the location (protection from the weather).
RISQUES DE DÉCHARGES ÉLECTRIQUES
Couper l’alimentation avant le dépannage ou avant l’installation du produit. Le module DEL doit être installé dans une tête de signal
avec une protection adéquate d’entrée pour l’emplacement (protection contre les intempéries).
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAN ICES-005 (A)/NMB-005(A)
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Important Information
• Use only with approved microprocessor-based controllers (refer to label on module cover) as follows:
GETS: EL2, VHLC, EC4, EC5
US & S: MICROLOCK II VERSION 8
• Vital programmable control systems or relay flashers are the only approved means of flashing the LED signal.
• LED module fits into most standard railway signal heads.
• LED module is self-contained – no assembly is required.
• As per AREMA guidelines, provisions should be made for periodic functional checks of safety devices and
features incorporated into this product.
• Current recommends that primary and secondary surge protection be added additional to the tertiary surge
protection in the lamp. Arema 11.3.3
• This product is intended solely for the use of rail signaling and is not intended for use in any other application.