Capacity Range
SiUS342004EB
17
Part 1 General Information
4. Capacity Range
4.1 Connection Ratio
4.2 Outdoor Unit Combinations
Type
Min.
combination
ratio
Max. combination ratio
Types of connected indoor units
Type of connected
air treatment equipment
When using only
FXFQ12-54AA,
FXDQ-M,
FXSQ07-54TA,
FXSQ07-54TB,
FXMQ-PB,
FXAQ-P
When using at
least one
FXFQ07/09AA,
FXFQ07/09T,
FXZQ05TA,
FXZQ05TB,
FXSQ05TA,
FXSQ05TB
When using
other indoor
unit models
FXMQ-MF
When
FXMQ-MF
is only
connected
When
FXMQ-MF
and indoor
units are
connected
Single
outdoor units
50%
1
200%
2
180%
2
200%
2
100%
100%
3
Double
outdoor units
160%
2
160%
2
Triple
outdoor units
130%
2
130%
Notes:
1.
2.
3.
4.
RXYQ72XA, RXYQ72XB: 70%
If the operational capacity of indoor units is more than 130%, low airflow
operation is enforced in all the indoor units. This limitation can be deactivated
through field setting. Refer to page 188 for detail.
When outdoor-air processing units (FXMQ-MF) and standard indoor units are
connected, the total connection capacity of the outdoor-air processing units
(FXMQ-MF) must not exceed 30% of the capacity index of the outdoor units. And
the connection ratio must not exceed 100%.
Regarding the combinations related to the low-temperature hydrobox (HXY-TA),
refer to the service manual SiUS392016EA. Low-temperature hydrobox can only
be connected to single module outdoor units.
Connection ratio =
Total capacity index of the indoor units
Capacity index of the outdoor units
Capacity range (ton)
6
8
10
12
14
16
18
RXYQ
72XA
72XB
96XA
96XB
120XA
120XB
144XA
144XB
168XA
168XB
192XA
192XB
216XA
216XB
Max. number of
connectable indoor units
12
16
20
25
29
33
37
Total capacity index of
indoor units to be
connected
1
51-93
(144)
48-124
(192)
60-156
(240)
72-187
(288)
84-218
(336)
96-249
(307)
108-280
(345)
Capacity range (ton)
20
22
24
26
28
30
32
RXYQ
240XA
240XB
264XA
264XB
288XA
288XB
312XA
312XB
336XA
336XB
360XA
360XB
384XA
384XB
Max. number of
connectable indoor units
41
45
49
54
58
62
64
Total capacity index of
indoor units to be
connected
1
120-312
(384)
132-343
(422)
144-374
(460)
156-405
(499)
168-436
(537)
180-468
(468)
192-499
(499)
Notes:
1. Values inside brackets are based on connection of indoor units rated at maximum capacity, 200% for
single outdoor units, 160% for double outdoor units and 130% for triple outdoor units.
Summary of Contents for VRV RXYQ72-384XAYCA
Page 1: ...Service Manual RXYQ72 384XAYCA RXYQ72 384XBYCA Heat Pump 60 Hz SiUS342004EB...
Page 395: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 388 FXFQ07 09 12 15 18 24 30 36 48TVJU 3D086460B...
Page 397: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 390 FXZQ05 07 09 12 15 18TAVJU 3D110443A...
Page 401: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 394 FXEQ07 09 12 15 18 24PVJU 3D098557A...
Page 402: ...Wiring Diagrams SiUS342004EB 395 Part 7 Appendix FXDQ07 09 12 18 24MVJU C 3D050501C...
Page 409: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 402 FXHQ12 24 36MVJU 3D048116C...
Page 410: ...Wiring Diagrams SiUS342004EB 403 Part 7 Appendix FXAQ07 09 12 18 24PVJU 3D075354F...
Page 418: ...Wiring Diagrams SiUS342004EB 411 Part 7 Appendix VAM1200GVJU 3D073270D...