Troubleshooting by Error Code
SiUS342004EB
227
Part 6 Service Diagnosis
U0 - 05
Refrigerant shortage warning (cooling)
Refer to the
U0
flowchart and make a diagnosis of the
relevant unit based on the Error code shown to the left.
U0 - 06
Refrigerant shortage warning (heating)
U1 - 01
Reverse phase/open phase of power supply (Master)
Refer to the
U1
flowchart and make a diagnosis of the
relevant unit based on the Error code shown to the left.
U1 - 04
Reverse phase/open phase of power supply
(when power ON) (Master)
U1 - 05
Reverse phase/open phase of power supply (Slave 1)
U1 - 06
Reverse phase/open phase of power supply
(when power ON) (Slave 1)
U1 - 07
Reverse phase/open phase of power supply (Slave 2)
U1 - 08
Reverse phase/open phase of power supply
(when power ON) (Slave 2)
U2 - 01
Shortage of inverter 1 power supply voltage (Master)
Make a diagnosis of the relevant unit based on the
following.
Shortage of power supply voltage
If the other units detect shortage of power supply voltage,
power supply voltage during operation may be unstable.
Check the power supply condition.
If a particular unit detects the error, operation of 52C may
be defective. Follow the
U2
flowchart.
Open phase of power supply
The wiring between power supply and inverter PCB may be
disconnected. Check that power supply is connected to
terminal block, terminal block is connected to PCB without
broken wire or disconnection, and reactor wiring is
secured. If no abnormality is found, follow the
U2
flowchart.
Defective capacitor in main circuit
P-N on the inverter PCB (electrolytic capacitor, power
module) may be damaged and short circuited. Operation of
current limiting relay may be defective or the wiring
between the reactor and PCB may be disconnected.
Measure the resistance between P-N on the inverter PCB
and check for short circuit. If no abnormality is found, follow
the
U2
flowchart.
U2 - 02
Open phase of inverter 1 power supply (Master)
U2 - 03
Defective capacitor in inverter 1 main circuit (Master)
U2 - 08
Shortage of inverter 1 power supply voltage (Slave 1)
U2 - 09
Open phase of inverter 1 power supply (Slave 1)
U2 - 10
Defective capacitor in inverter 1 main circuit (Slave 1)
U2 - 11
Shortage of inverter 1 power supply voltage (Slave 2)
U2 - 12
Open phase of inverter 1 power supply (Slave 2)
U2 - 13
Defective capacitor in inverter 1 main circuit (Slave 2)
U2 - 36
Fan motor 1 undervoltage (Master)
U2 - 37
Fan motor 2 undervoltage (Master)
U2 - 38
Fan motor 1 undervoltage (Slave 1)
U2 - 39
Fan motor 2 undervoltage (Slave 1)
U2 - 40
Fan motor 1 undervoltage (Slave 2)
U2 - 41
Fan motor 2 undervoltage (Slave 2)
U3 - 02
Initial installation warning
Refer to the
U3
flowchart and make a diagnosis of the
relevant unit based on the Error code shown to the left.
U3 - 03
Test operation not conducted
U3 - 04
Abnormal end of test operation
U3 - 05
Premature end of test operation during initial transmission
error
U3 - 06
Premature end of test operation during normal
transmission error
U3 - 07
Premature end of test operation due to transmission error
of either unit
U3 - 08
Premature end of test operation due to transmission error
of all units
U4 - 01
Transmission error between indoor units and outdoor units Refer to the
U4
flowchart and make a diagnosis of the
relevant unit based on the Error code shown to the left.
U4 - 03
Transmission error between indoor unit and system
U7 - 01
Error when external control adaptor for outdoor unit is
installed
Refer to the
U7
flowchart and make a diagnosis of the
relevant unit based on the Error code shown to the left.
U7 - 02
Warning when external control adaptor for outdoor unit is
installed
U7 - 03
Transmission error between master and slave 1 units
U7 - 04
Transmission error between master and slave 2 units
U7 - 05
Multi system error
U7 - 06
Error in address settings of slave 1 and 2
U7 - 07
Connection of four or more outdoor units in the same
system
U7 - 11
Error in indoor unit connection capacity for test operation
Error code
Troubleshooting
Error Description
Diagnosis
Summary of Contents for VRV RXYQ72-384XAYCA
Page 1: ...Service Manual RXYQ72 384XAYCA RXYQ72 384XBYCA Heat Pump 60 Hz SiUS342004EB...
Page 395: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 388 FXFQ07 09 12 15 18 24 30 36 48TVJU 3D086460B...
Page 397: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 390 FXZQ05 07 09 12 15 18TAVJU 3D110443A...
Page 401: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 394 FXEQ07 09 12 15 18 24PVJU 3D098557A...
Page 402: ...Wiring Diagrams SiUS342004EB 395 Part 7 Appendix FXDQ07 09 12 18 24MVJU C 3D050501C...
Page 409: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 402 FXHQ12 24 36MVJU 3D048116C...
Page 410: ...Wiring Diagrams SiUS342004EB 403 Part 7 Appendix FXAQ07 09 12 18 24PVJU 3D075354F...
Page 418: ...Wiring Diagrams SiUS342004EB 411 Part 7 Appendix VAM1200GVJU 3D073270D...