Field Settings for Indoor Unit
SiUS342004EB
167
Part 5 Field Settings and Test Operation
Whether operation by remote controller will be possible or not for turning ON/OFF, controlling
temperature or setting operation mode is selected and decided by the operation mode given on the
right edge of the table below.
: Factory setting
Do not select
Timer operation possible by remote controller
if not using a remote controller.
Operation by timer is impossible in this case.
How to Select Operation Mode
ON by remote
controller
(Unified ON by
central remote
controller)
OFF by remote
controller
(Unified OFF by
central remote
controller)
Temperature
control by
remote controller
Operation mode
setting by
remote controller
OFF by
remote
controller
Example
↓
Rejection
↓
Rejection
↓
Rejection
↓
Acceptance
↓
Acceptance
Control
mode is
1
.
Control mode
Control by remote controller
Control mode
Operation
OFF
Temperature
control
Operation
mode setting
Unified operation,
individual operation by
central remote
controller, or operation
controlled by timer
Unified OFF, individual
stop by central remote
controller, or timer stop
ON/OFF control
impossible by
remote controller
Rejection (Example)
Rejection (Example)
Rejection
(Example)
Rejection
Acceptance
0
Rejection
10
Acceptance
(Example)
Acceptance
(Example)
1 (Example)
Rejection
11
OFF control only
possible by remote
controller
Acceptance
Rejection
Acceptance
2
Rejection
12
Acceptance
Acceptance
3
Rejection
13
Centralized
Acceptance
Rejection
Acceptance
4
Rejection
14
Acceptance
Acceptance
5
Rejection
15
Individual
Acceptance
Rejection
Acceptance
6
Rejection
16
Acceptance
Acceptance
7
Rejection
17
Timer operation
possible by remote
controller
Acceptance
(During timer at ON
position only)
Rejection
(During timer at OFF
position only)
Rejection
Acceptance
8
Rejection
18
Acceptance
Acceptance
9
Rejection
19
Local remote controllers cannot set
temperature or operation mode
w
hen
the system is under centralized control
and
CENTRAL CONTROL
is displayed
on the screen.
BRC1E73
Summary of Contents for VRV RXYQ72-384XAYCA
Page 1: ...Service Manual RXYQ72 384XAYCA RXYQ72 384XBYCA Heat Pump 60 Hz SiUS342004EB...
Page 395: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 388 FXFQ07 09 12 15 18 24 30 36 48TVJU 3D086460B...
Page 397: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 390 FXZQ05 07 09 12 15 18TAVJU 3D110443A...
Page 401: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 394 FXEQ07 09 12 15 18 24PVJU 3D098557A...
Page 402: ...Wiring Diagrams SiUS342004EB 395 Part 7 Appendix FXDQ07 09 12 18 24MVJU C 3D050501C...
Page 409: ...SiUS342004EB Wiring Diagrams Part 7 Appendix 402 FXHQ12 24 36MVJU 3D048116C...
Page 410: ...Wiring Diagrams SiUS342004EB 403 Part 7 Appendix FXAQ07 09 12 18 24PVJU 3D075354F...
Page 418: ...Wiring Diagrams SiUS342004EB 411 Part 7 Appendix VAM1200GVJU 3D073270D...