Replacement Procedure for INV Compressor, VRV II (REYQ8M-48M)
Si39-306
236
Replacement Procedure for INV Compressor, VRV II (REYQ8M to 48M)
1.
Replacement Procedure for INV Compressor,
VRV II (REYQ8M-48M)
1.1
Replacement Procedure
(1) Collect the refrigerant by using refrigerant
recovery unit.
(Since the setting on outdoor unit PCB is required
for refrigerant recovery, refer to the warning plate
"Precautions in service work" attached on the
switch box cover.)
(2) Remove the sound insulator mat covering the
faulty compressor, and disconnect the power
cable from terminal board of the compressor.
(3) Disconnect the brazing sections of suction pipe
and discharge pipe by using brazing torch after
the refrigerant has been collected completely.
(4) Pinch the oil pressure equalizing pipe of the faulty
compressor at the lower part of the brazed joint as
shown in figure 1, and cut it between the pinched
section and brazed joint in order to prevent
residual oil from discharging.
(5) Remove three bolts at cushion rubber section to
take out the faulty compressor outside the unit.
(6) Check that no oil remains in the oil pressure
equalizing pipe as shown in figure 2, then remove
the cut pipe from the brazed joint with brazing
torch.
(7) Install the new compressor in the unit.
(Be sure to insert the cushion rubbers before
tightening the fixing bolts of compressor.)
(8) Remove the rubber caps put on the suction and
discharge pipe of the new compressor to release
the sealing nitrogen gas.
(Take note that oil may spout due to the pipe
inside pressure if the plug put on the equalizing
seat is removed before removing of rubber cap.)
(9) Remove the plug put on the equalizing seat of the
new compressor.
(10) Install the outlet pipe on the equalizing seat of the
new compressor.
(11) Braze the equalizing seat outlet pipe to the oil
pressure equalizing pipe with brazing torch.
* Since an O-ring is put in the equalizing seat, be
sure to maintain the parts around O-ring in cool.
(12) Braze the suction and discharge pipe with brazing
torch to the compressor.
(13) Conduct air tight test to check the piping system is
free from leakage.
(14) Connect power cable to the terminal board of
compressor and cover the compressor with sound
insulator mat.
(15) Conduct vacuum drying.
(Since the setting on outdoor unit PCB is required for vacuum drying, refer to the warning
plate “Precautions in service work” attached on the switch box cover.)
(16) Charge refrigerant after the completion of vacuum drying, and check the function of
compressor with cooling or heating operation.
Suction pipe
Discharge pipe
INV
compressor
Oil equalizing
pipe
Equalizing seat
Bolts
Cushion
rubber
Brazed section
2. Cut
1. Pinch
Equalizing seat outlet pipe
Equalizing seat
Fig. 1
Oil pressure equalizing pipe
Brazed section
Cut section
Remove
* Check that no oil remains in the oil pressure
equalizing pipe before removing of the cut
pipe.
Fig. 2
Summary of Contents for VRV II REYQ8MY1B
Page 19: ...Model Selection Si39 306 8 General Information...
Page 150: ...Si39 306 Troubleshooting by Remote Controller Troubleshooting 139...
Page 250: ...Si39 306 Piping Diagrams Appendix 239 REYQ14MY1B REYQ16MY1B 4D042070A...
Page 252: ...Si39 306 Piping Diagrams Appendix 241 1 3 BS Unit BSVQ100MV1 BSVQ160MV1 BSVQ250MV1 4D042115...
Page 254: ...Si39 306 Wiring Diagrams for Reference Appendix 243 REYQ14MY1B REYQ16MY1B 3D038572...
Page 256: ...Si39 306 Wiring Diagrams for Reference Appendix 245 REYQ18 20 22 24 26 28 30 32MY1B 3D043436...
Page 257: ...Wiring Diagrams for Reference Si39 306 246 Appendix REYQ34 36 38 40 42 44 46 48MY1B 3D043437...
Page 259: ...Wiring Diagrams for Reference Si39 306 248 Appendix FXCQ40M 50M 80M 125MVE 3D039557A...
Page 260: ...Si39 306 Wiring Diagrams for Reference Appendix 249 FXZQ20M 25M 32M 40M 50MVE 3D038359...
Page 262: ...Si39 306 Wiring Diagrams for Reference Appendix 251 FXKQ25M 32M 40M 63MVE 3D039564A...
Page 264: ...Si39 306 Wiring Diagrams for Reference Appendix 253 FXMQ40M 50M 63M 80M 100M 125MVE 3D039620A...
Page 265: ...Wiring Diagrams for Reference Si39 306 254 Appendix FXMQ200M 250MVE 3D039621A...
Page 266: ...Si39 306 Wiring Diagrams for Reference Appendix 255 FXHQ32M 63M 100MVE 3D039801C...
Page 267: ...Wiring Diagrams for Reference Si39 306 256 Appendix FXAQ20M 25M 32MVE 40M 50M 63MVE 3D034206A...
Page 283: ...REFNET Pipe System Si39 306 272 Appendix...
Page 284: ...Si39 306 Appendix 273 DPSOH RI RQQHFWLRQ 5 7 SH 5 4 0 HDW 5HFRYHU...
Page 285: ...Si39 306 274 Appendix...
Page 291: ...Method of Replacing The Inverter s Power Transistors and Diode Modules Si39 306 280 Appendix...
Page 305: ...Si39 306 iv Index...