11
Note: The parameters above are measured at standard conditions of water tank initial water temperature 15ºC, final water
temperature 55ºC.
Model
Ambient temp. ºC
-10
0
7
10
15
20
25
30
35
40
43
UHA075B5
Heating capacity (kW)
16.50
21.30
24.50
25.80
27.90
30.00
31.90
33.80
34.90
36.00
37.90
Heating power (kW)
6.54
6.65
6.72
6.75
6.79
6.83
6.84
6.84
6.71
6.57
6.63
COP
2.53
3.21
3.64
3.82
4.11
4.39
4.67
4.95
5.22
5.48
5.72
Water production (m
3
/h)
0.36
0.46
0.53
0.56
0.60
0.65
0.69
0.73
0.75
0.77
0.81
UHA100B5
Heating capacity (kW)
22.00
28.50
32.60
34.40
37.20
40.00
42.55
45.10
46.55
48.00
50.50
Heating power (kW)
8.34
8.49
8.57
8.61
8.66
8.71
8.72
8.72
8.55
8.37
8.45
COP
2.64
3.35
3.81
4.00
4.30
4.59
4.88
5.17
5.45
5.73
5.98
Water production (m
3
/h)
0.47
0.61
0.70
0.74
0.80
0.86
0.92
0.97
1.00
1.03
1.09
UHA200B5
Heating capacity (kW)
44.10
56.90
65.30
68.90
74.45
80.00
85.10
90.20
93.10
96.00
101.00
Heating power (kW)
17.45
17.75
17.93
18.01
18.12
18.22
18.23
18.24
17.88
17.51
17.68
COP
2.52
3.21
3.64
3.82
4.11
4.39
4.67
4.94
5.21
5.48
5.71
Water production (m
3
/h)
0.95
1.22
1.40
1.48
1.60
1.72
1.83
1.94
2.00
2.07
2.17
Water Pressure Drop Curve
UHA075B5
Water Pressure Drop Curve
DMHA075B5
DMHA100B5
DMHA200B5
MHA075B5
0
10
20
30
40
50
60
70
80
0
1
2
3
4
5
6
7
8
9
水流量(
m3/h
)
水阻力(
kPa
)
Water flow (m
3
/h)
W
at
er
p
re
ss
ur
e
dr
op
(k
P
a)
DMHA075B5
MHA100B5
0
20
40
60
80
100
120
140
160
水流量(
m3/h
)
水阻力(
kPa
)
W
at
er
p
re
ss
ur
e
dr
op
(k
P
a)
Water flow (m
3
/h)
DMHA100B5
MHA200B5
0
20
40
60
80
100
120
140
0
2
4
6
8
10
12
14
16
18
20
水流量(
m3/h
)
水阻力(
kPa
)
W
at
er
p
re
ss
ur
e
dr
op
(k
P
a)
Water flow (m
3
/h)
DMHA200B5
80
70
60
50
40
30
20
10
0
0
1
2
3
4
5
6
7
8
UHA075B5
9