background image

FTXS50GVMA FTKS50GVMA
FTXS60GVMA FTKS60GVMA
FTXS71GVMA FTKS71GVMA
FTXS80GVMA
FTXS90GVMA

MODELS

DAIKIN ROOM AIR CONDITIONER

Operation Manual

00_CV_3P232468-4.fm  Page 1  Wednesday, June 4, 2008  3:13 PM

Summary of Contents for TXS50GVMA

Page 1: ...FTXS50GVMA FTKS50GVMA FTXS60GVMA FTKS60GVMA FTXS71GVMA FTKS71GVMA FTXS80GVMA FTXS90GVMA MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual...

Page 2: ...7 OPERATION AUTO DRY COOL HEAT FAN Operation 10 Adjusting the Air Flow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT QUIET Operation 15 HOME LEAVE Operation 16 INTELLIGENT EYE Operation 18 TIMER Op...

Page 3: ...our service staff Do not attempt to install the air conditioner by your self Incorrect work will result in water leakage electric shocks or fire For installation consult the dealer or a qualified tec...

Page 4: ...d the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunctions smoke or fire when making contact with electrical parts Do not operate th...

Page 5: ...4 Names of parts Indoor Unit 1 2 4 3 10 11 9 7 8 15 12 13 14 16 6 5...

Page 6: ...e HOME LEAVE Operation page 16 15 Indoor Unit ON OFF switch Push this switch once to start operation Push once again to stop it The operation mode refer to the following table This switch is useful wh...

Page 7: ...E selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 15 9 FAN setting button It selects the air flow rate setting 10 SENSOR b...

Page 8: ...When the system is not used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates please repla...

Page 9: ...der to a wall a pillar etc with the screws supplied with the holder 3 Place the remote controller in the remote controller holder ATTENTION About remote controller Never expose the remote controller t...

Page 10: ...you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions Operation outside this humidity...

Page 11: ...e button advances the mode setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To c...

Page 12: ...operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does...

Page 13: ...begin to swing 2 When the flap has reached the desired position press SWING button once more The flap will stop moving disappears from the LCD To adjust the vertical blades louvers 3 Press SWING butto...

Page 14: ...the operation mode See the figure Three Dimensional 3 D Airflow Using three dimensional airflow circulates cold air which tends to collected at the bottom of the room and hot air which tends to collec...

Page 15: ...s on POWERFUL operation POWERFUL Operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD Priority is gi...

Page 16: ...ti system this function will work only when the OUTDOOR UNIT QUIET operation is set on all operated indoor units However if using priority room setting see Note for multi system page 22 This function...

Page 17: ...sing HOME LEAVE operation for the first time please set the temperature and air flow rate for HOME LEAVE operation Record your preferred temperature and air flow rate 1 Press HOME LEAVE button Make su...

Page 18: ...a comfortably air conditioned room Push the HOME LEAVE Operation button again and the air conditioner will adjust capacity to the set temperature for normal operation Set the unit to HOME LEAVE Operat...

Page 19: ...n 1 Press SENSOR button is displayed on the LCD To cancel the INTELLIGENT EYE operation 2 Press SENSOR button again disappears from the LCD EX TIMER ON CANCEL OFF QUIET 1 2 When somebody in the room N...

Page 20: ...passersby temperature range etc The sensor also mistakenly detects pets sunlight fluttering curtains and light reflected off of mirrors as passersby INTELLIGENT EYE operation will not go on during pow...

Page 21: ...ges the setting rapidly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER Operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the present time...

Page 22: ...ges the setting rapidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample set...

Page 23: ...ease consult your retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGHT QUIET Mode...

Page 24: ...g If the unit in Room A enters POWERFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduce...

Page 25: ...p in the shade after washing 4 Attach the front panel Align the rotation dowels on the left and right of the front panel with the slots then push them all the way in Close the front panel slowly Press...

Page 26: ...off easily wash them with neutral detergent thinned with lukewarm water then dry them up in the shade It is recommended to clean the air filters every two weeks Titanium Apatite Photocatalytic Air pur...

Page 27: ...e air 2 cannot clean the air 3 results in poor heating or cooling 4 may cause odour To order Titanium Apatite Photocatalytic Air Purifying Filter contact to the service shop there you bought the air c...

Page 28: ...Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mist comes out of the indoor unit This happens when the air in the room is cooled into mist by the cold ai...

Page 29: ...and the outdoor units Clean the air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still...

Page 30: ...y get foul after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenanc...

Page 31: ...30 MEMO...

Page 32: ...31 MEMO...

Page 33: ...32 MEMO...

Page 34: ...0808 HT Two dimensional bar code is a code for manufacturing 3P232468 4 M08B038...

Reviews: