background image

11

Wire Connections

If the terminal designations on your old thermostat do not 
match those on the new thermostat, refer to the chart below or 

the wiring diagrams that follow.

 

Wire from the  

 

Install on the   

 

old thermostat 

Function  

new thermostat 

  terminal marked 

 

connector marked

 

Common 

C (optional)

 

Rh, R, M, Vr, A 

Power 

RH* 

 

 

(Heating Transformer)

 

Y1  or Y 

Cooling 

Y

 

W1, W or H 

Heating 

W

 

G or F 

Fan 

G

 

RC, R, M, Vr, A 

Power 

RC* 

 

 

(Cooling Transformer) 

 

 

O/B 

Rev. Valve 

O/B

* The RC and RH terminals have a factory installed jumper to control 
single transformer systems. Remove this jumper to control dual 
transformer systems.

Thermal Insulating Sheet

A label is provided on the backplate 
that prevents drafts originating inside 
the wall from entering the thermostat.

These drafts, left unchecked, may cause 
incorrect room temperature readings. 

Please do not remove this label from  
the thermostat. Insert the wires  
through the slots provided in  
the label as shown in Fig. 1.

Wire

Slots

C O/B

Y

W G RC RH

4Z95

MODEL: TSTATD1100-2

    97061606

MADE IN CHINA

USE SIZE “AA”

ALKALINE BATTERIES

Summary of Contents for TSTATD1100-2

Page 1: ...Owner s Manual and Installation Instructions TSTATD1100 2 RESIDENTIAL for Residential Use DigitalThermostat Non Programmable...

Page 2: ...t Panel 4 Dispay 5 Normal Operation 6 Fahrenheit or Celsius 7 Preparation 8 Remove Old Thermostat 9 Battery Replacement 10 Wire Connections 11 Sample Wiring Diagrams 12 Jumper Configuration 18 Test Op...

Page 3: ...es are not immediately replaced Annual battery replacement is especially critical in locations subject to freezing temperatures The thermostat will be unable to turn on the heating system if the batte...

Page 4: ...OLER WARMER BUTTONS DISPLAY HEAT BATTERIES COOL OFF FAN HEAT AUTO ON On or Auto FAN SWITCH BI COLOR LED Heat or Cool demand indicator when system powered Red Heat Green Cool MODE SWITCH Cool Off or He...

Page 5: ...re 3 Desired set temperature indicator When this indicator is on the large numbers represent the desired room temperature Pressing the COOLER or WARMER button during normal operation will cause the la...

Page 6: ...n Auto the fan will turn on only with a heat or cool demand When Fan On is selected the fan will run continuously 3 Adjust the desired set temperature with the COOLER and WARMER buttons Operation COOL...

Page 7: ...the COOLER and WARMER buttons at the same time until the temperature is displayed in degrees Celsius 3 Repeat this process to display the temperature in degrees Fahrenheit Operation COOLER WARMER BUT...

Page 8: ...e tools will be required Make sure your Heater Air Conditioner is working properly before beginning installation of the thermostat Carefully unpack the thermostat Save the screws and instructions Turn...

Page 9: ...ng the thermostat base or subbase to the wall and lift away Disconnect the wires from the old thermostat Tape the ends of the wires as you disconnect them and mark them with the letter of the terminal...

Page 10: ...re easily accessible from the battery door located on the bottom front of the thermostat fig 1 To open the battery slot pull out on the battery door fig 1 and swing down fig 2 Remove the old batteries...

Page 11: ...rmer O B Rev Valve O B The RC and RH terminals have a factory installed jumper to control single transformer systems Remove this jumper to control dual transformer systems Thermal Insulating Sheet A l...

Page 12: ...in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is d...

Page 13: ...ire is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery...

Page 14: ...re is optional in all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery...

Page 15: ...all installations If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is disp...

Page 16: ...If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed page 3 POWER...

Page 17: ...n terminal If a common wire is not used the thermostat must be powered by two AA alkaline batteries These batteries must be replaced page 10 each year or when the Low Battery indicator is displayed pa...

Page 18: ...t used OUTPUTS No Demand With Demand Cooling Mode Heating Mode O B Y G O B O B W O B 1000 JFK SKD 1000 JFK SKD 1000 JFK SKD 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471...

Page 19: ...not used OUTPUTS No Demand With Demand Cooling Mode Heating Mode O B Y G O B O B W G O B 1000 JFK SKD 1000 JFK SKD 1000 JFK SKD 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471 471...

Page 20: ...for typical heat pump operation Note Thermostat does not have Auxiliary Heat Emergency Heat capability OUTPUTS No Demand With Demand Cooling Mode Heating Mode O Y G O Y G 1000 JFK SKD 1000 JFK SKD 100...

Page 21: ...typical heat pump operation Note Thermostat does not have Auxiliary Heat Emergency Heat capability OUTPUTS No Demand With Demand Cooling Mode Heating Mode Y G B Y G B 1000 JFK SKD 1000 JFK SKD 1000 JF...

Page 22: ...pressor lockout feature On the thermostat slide the Mode Switch to HEAT Press the COOLER or WARMER buttons until the set temperature is 10 degrees below room temperature The HVAC unit should energize...

Page 23: ...tion in this manual to Lower the cooling L setpoint Page 6 Correct the Mode Switch position Page 6 Replace the batteries Page 10 SYMPTOM The fan does not turn on even though the compressor has energiz...

Page 24: ...52 2 and 2152 2 2200C 2 4271C 4272C 2111 2 4272 4273 Some states and provinces do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you DAIKIN SHALL...

Page 25: ...Printed on recycled paper P N 88 993 Rev 1 12 13 C c F FOR HOME OR OFFICE USE Tested to Comply with FCC Standards Battery Stat 4Z95 P N TSTATD1100 2...