background image

19

Maintenance

 WARNING

Before cleaning and maintenance work, be sure to unplug 
the unit. (An electric shock or injury may result)

Maintenance

(Left-side)

(Front)

(Right-

side)

Outflow Grille

When dirt becomes an issue

  

Wipe

      

Wash/Rinse

•  Wipe up dirt with a soft damp 

cloth and rinse with water.

•  Do not use a hard brush etc. 

(Damage may result)

•  When dirt buildup is severe, 

leave the part soaking in 
lukewarm or room temperature 
water mixed with kitchen-use 
neutral detergent, thoroughly 
rinse off the detergent, and leave 
the part in shade to dry off.

Removing

Place fingers 

into the notches 
in the top of the 
unit and lift.

Attaching

Pay attention 
to orientation 
and attach 
securely.

Unit

When dirt becomes an issue 

 

Wipe

•  Wipe up dirt with a soft damp cloth.
•  When dirt buildup is severe, wipe up the dirt with a cloth which has 

been moistened with kitchen-use neutral detergent.

•  Do not use a hard brush etc. (Damage may result)

Pre-filter 

(Front/Left-side/Right-side)

About every 2 weeks

Vacuum clean

Wash/Rinse

•  After removing any dust using a 

vacuum cleaner, remove and 

wash the filter with water and 

then leave it in shade to dry off.

•  Use a soft brush when cleaning 

the spaces in the grid.

Attention

•  Do not use a cotton bud or hard 

brush etc. 

(Partial breakage of the filter may 

result)

•  Do not apply heavy force. (Partial 

breakage/damage of the filter may 

result)

Removing

Grip the notch in the 

pre-filter and pull.

1  Grip either end of 

the pre-filter resting 

your thumb against 
the unit.

2  Pull  toward 

you.

Attaching

Insert the hooks 
(2 places) into 
the unit and 
press until you 
hear a catching 
sound.

Hooks 

(2 places)

Insert the hook 

(1 place) into the 

unit.
Push both ends 
until securely 
attached.

Hook (1 place)

Viewed from above

Reverse side

•  When dirt buildup is severe, 

leave the part soaking in 
lukewarm or room temperature 
water mixed with kitchen-use 
neutral detergent, thoroughly 
rinse off the detergent and leave 
the part in shade to dry off.

Dust/PM2.5 Sensor

When dust has built up

Vacuum clean

1

 Remove the pre-filter (left-side).

2  Vacuum off any dust that has adhered to 

the air intake for dust/PM2.5 sensor using 
the vacuum cleaner crevice tool or similar.

1

2

2

Move the  

catch and pull

Lens 

(internal 

part)

Air intake for dust/PM2.5 sensor

About every 3 months

  

Wipe

1

 Remove the pre-filter (left-side) and the 

cover for the air intake for dust/PM2.5 
sensor.

2

 Wipe the lens with 

a dry cotton bud

.

Lens

Use a light if hard 
to see

Use the vacuum cleaner crevice tool or similar to 
remove any dust that has built up around the lens.

3

 Place the cover on securely. 

(Malfunction may result if the cover is off)

01_EN_3P595629-1B.indd   19

2020/04/17   16:01:55

Summary of Contents for STREAMER C55WVM

Page 1: ...d the operation manual carefully and follow it for correct use Please read the Safety Precautions section before use Please keep the operation manual in a safe place for later reference Air Puri er Pa...

Page 2: ...1 01_EN_3P595629 1B indd 1 2020 04 17 16 01 48...

Page 3: ...ing the Unit in a MODE 13 AUTO FAN ECONO ANTI POLLEN Using the Child Proof Lock 15 Adjusting Indicator Lamp Brightness 15 Operation Using Air Purifying Operation 12 Changing the Airflow Rate 12 Mainte...

Page 4: ...ects on the power supply plug or cord If the power supply plug or cord is damaged it must be replaced by the manufacturer its service agent or a similar qualified person in order to avoid a hazard An...

Page 5: ...if the switch is turned on Current passes through the cord or fails to pass through if the cord is moved There are abnormal sounds or vibrations during operation The casing of the unit has become defo...

Page 6: ...chew on the power supply cord Fire an electric shock or injury may result Concerning the unit body Do not block the air inlets or air outlet with laundry cloth curtains etc Overheating or fire may res...

Page 7: ...t PM2 5 sensor Inside the air inlet left side Page 7 17 19 Model name Production no Manufacturing date MFG DATE Air inlets Front Side Power supply cord Air outlet Power supply plug Main Removable Part...

Page 8: ...dour perception varies by person in some cases an odour may be sensed even when the lamp is green If the odour bothers you switch to manual airflow rate and select a high airflow rate Page 12 Odour se...

Page 9: ...gnals if anything is blocking the signals such as a curtain Maximum transmission range is approx 6m straight line Remote controller ON OFF button Press to turn the power ON or OFF Page 12 FAN button P...

Page 10: ...to direct sunlight A decline in the receptivity of the signal from the remote controller or discolouration may result Positions near combustion based heating and other high temperature devices Discol...

Page 11: ...eading the frame 3 While pressing the protrusions on the hooks large on the front side of the deodorising filter unit push the deodorising filter in and set it under the hooks large in 2 places to att...

Page 12: ...mark face same direction Catch mark About the battery Keep batteries out of reach of children In the event that batteries are swallowed go immediately to the nearest medical emergency services To avo...

Page 13: ...eep hours As the deodorising capacity is reduced it is recommended that the FAN setting be set to Standard or above if odour needs to be quickly eliminated from a room Turbo The ambient air is quickly...

Page 14: ...sted automatically when the unit is running in a MODE Remote controller Press Each press cycles between the MODE lamps green AUTO FAN ECONO ANTI POLLEN Unit Press Each press cycles between the MODE la...

Page 15: ...immediately after the unit was turned on Power saving mode If the air is clean after a short while Monitoring mode The fan starts and stops periodically Dust and odours are monitored The following fu...

Page 16: ...unplugged when child proof lock is active child proof lock is turned off The child proof lock lamp orange lights up when the function is active Adjusting Indicator Lamp Brightness Indicator lamp brigh...

Page 17: ...Note It is recommended that the streamer be set to Regular as deodorising capacity is reduced when set to Low Settings are remembered even if the unit is unplugged Blinking Lit up When you want to tu...

Page 18: ...to change the sensitivity To set sensitivity High Select the FAN lamp Turbo Turbo Standard Low High Normal Low The sensor is highly receptive The sensor is slightly receptive Setting at time of purcha...

Page 19: ...will remain lit up To turn Monitoring mode ON Turn on the ECONO MODE lamp Setting at time of purchase ON OFF To turn Monitoring mode OFF Turn off the ECONO MODE lamp Setting is indicated using the EC...

Page 20: ...rush etc Partial breakage of the filter may result Do not apply heavy force Partial breakage damage of the filter may result Removing Grip the notch in the pre filter and pull 1 Grip either end of the...

Page 21: ...d the location of the unit Standard replacement time is about 10 years assuming that the unit is used daily in a home where 5 cigarettes are smoked a day Calculation in accordance with testing method...

Page 22: ...bly pulling 2 1 Connector Hook 2 Push in the left side of the streamer unit so the right side comes out You will hear a catching sound 3 Remove the streamer unit 4 Flip up the protective covers and at...

Page 23: ...tains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Hg mercury 0 0005 Disposal of this product must be done in accordance with relevant local and national leg...

Page 24: ...outflow grille and dust collection filter attached These lamps may blink if the unit is operated without a part attached If all the parts are attached An electrical component is faulty Contact the pla...

Page 25: ...tion Dust PM2 5 sensor Q Can the dust collection filter be cleaned A No Do not attempt to clean it with a vacuum cleaner or water Reduced performance of the dust collection filter may result Replace i...

Page 26: ...age range protection 180V 264V Unit will not operate Is the streamer unit cover attached If it is not attached the safety switch will engage and the unit cannot operate Install the streamer unit cover...

Page 27: ...cotton bud or similar Page 19 Is the pre filter dirty Page 19 Clean these parts After cleaning the unit will return to normal operation a short while after being turned on There is an odour but the od...

Page 28: ...ir inlet blocked If they are not blocked an electrical component is faulty Contact the place of purchase Other Phenomenon Check points The fan stops midway through unit operation When the unit switche...

Page 29: ...rate m h 330 192 120 66 Coverage area m 41 1 External dimensions mm 500 H 270 W 270 D Weight kg 6 8 Power supply cord length m 1 8 Made in China These specification values are applicable to both 50Hz...

Page 30: ...code is a manufacturing code DAIKIN ISITMA VE SO UTMA S STEMLER SAN T C A G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00...

Reviews: