Service Settings Menu, Maintenance Menu
SiUS281811EA
102
Part 3 Remote Controller
6.2 Wireless
Remote
Controller
6.2.1 Service Setting
1. Press
INSPECTION/TEST
button for 4 seconds during normal mode to enter field setting mode.
2. Press
INSPECTION/TEST
button for 4 seconds to enter service mode.
3. Press
MODE
buttons to select a desired mode number. (43)
4. Carry out the necessary setting with
UP
button or
DOWN
button.
5. Press
RESERVE
button to confirm the setting.
6. Press
INSPECTION/TEST
button to return to normal mode
Mode
No.
Function
Content and Operation
Method
Example of Remote Controller Display
43
Forced Fan
ON
Turns the fan ON for each unit
individually.
UP
button
DOWN
button
Mode number
RESERVE
button
MODE
button
INSPECTION/TEST
button