• Outdoor Unit • RZAG-MV1
2
• Split - Sky Air • RZAG-MV1
8
2
Specifications
Notes
(1) Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W]
(2) Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
2-4 Capacity and Power input
FDA125A/RZAG125MV1
Indoor unit
FDA125A5VEB
Outdoor unit
RZAG125M7V1B
Cooling capacity
Nom.
kW
12.1 (1)
Heating capacity
Nom.
kW
13.5 (2)
Space cooling
Capacity
Pdesign
kW
12.1
SEER
6.59
η
s,c
%
261
Annual energy consumption
kWh/a
1,102
A Condition (35°C -
27/19)
Pdc
kW
12.10
EERd
3.81
Power input
kW
3.17
B Condition (30°C -
27/19)
Pdc
kW
8.92
EERd
5.42
Power input
kW
1.65
C Condition (25°C -
27/19)
Pdc
kW
5.74
EERd
7.55
Power input
kW
0.76
D Condition (20°C -
27/19)
Pdc
kW
4.15
EERd
9.68
Power input
kW
0.43