background image

RZQSG-LV1

 

Technical Data

Air Conditioners

O u t d o o r   u n i t   -   O p t i m i z e d   f o r   s e a s o n a l   e f f i c i e n c y

E E D E N 1 2 - 1 0 0

Summary of Contents for RZQSG-LV1

Page 1: ...RZQSG LV1 Technical Data Air Conditioners O u t d o o r u n i t O p t i m i z e d f o r s e a s o n a l e f f i c i e n c y E E D E N 1 2 1 0 0...

Page 2: ...Heating Capacity Tables 17 Capacity Correction Factor 21 7 Dimensional drawings 22 Dimensional Drawings 22 8 Centre of gravity 24 Centre of Gravity 24 9 Piping diagrams 26 Piping Diagrams 26 Piping D...

Page 3: ...indication on how efficient an air conditioner operates over an entire heating or cooling season Re use of existing R 22 or R 407C technology The use of inverter type outdoor units results in an air...

Page 4: ...equivalent refrigerant piping 5m level difference 0m 5 Annual energy consumption is according to Energy labeling directive 2002 31 EC 6 SEER and SCOP are according to EN 14825 2 1 Nominal Capacity And...

Page 5: ...level difference 0m 4 Heating indoor temp 20 CDB outdoor temp 7 CDB 6 CWB equivalent refrigerant piping 5m level difference 0m 5 Annual energy consumption is according to Energy labeling directive 20...

Page 6: ...alent refrigerant piping 5m level difference 0m 5 Annual energy consumption is according to Energy labeling directive 2002 31 EC 6 SEER and SCOP are according to EN 14825 2 1 Nominal Capacity And Nomi...

Page 7: ...ling Nom kW 3 74 Heating Nom kW 3 85 EER 3 21 COP 3 51 SEER 4 35 6 SCOP 3 81 6 Annual energy consumption kWh 1 870 Energy label Cooling A Heating B 2 2 Technical Specifications RZQSG71LV1 RZQSG100LV1...

Page 8: ...t Min CWB 15 Max CWB 15 5 Refrigerant Type R 410A Charge kg 2 75 2 9 4 0 Control Expansion valve electronic type Circuits Quantity 1 Refrigerant oil Type FVC50K Charged volume l 0 75 0 9 1 35 Piping c...

Page 9: ...rawing for electrical data 6 European international technical standard setting the limits for harmonic currents produced by equipment connected to public low voltage system with input current larger t...

Page 10: ...3 1 3 Split Sky Air Outdoor Unit 9 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 3 Electrical data 3 1 Electrical Data...

Page 11: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 3 Split Sky Air Outdoor Unit 10 3 Electrical data 3 1 Electrical Data...

Page 12: ...3 1 4 Split Sky Air Outdoor Unit 11 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 4 Options 4 1 Options...

Page 13: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 5 Split Sky Air Outdoor Unit 12 5 Combination table 5 1 Combination Table...

Page 14: ...3 1 6 Split Sky Air Outdoor Unit 13 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 6 Capacity tables 6 1 Cooling Capacity Tables...

Page 15: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 6 Split Sky Air Outdoor Unit 14 6 Capacity tables 6 1 Cooling Capacity Tables...

Page 16: ...3 1 6 Split Sky Air Outdoor Unit 15 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 6 Capacity tables 6 1 Cooling Capacity Tables...

Page 17: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 6 Split Sky Air Outdoor Unit 16 6 Capacity tables 6 1 Cooling Capacity Tables...

Page 18: ...3 1 6 Split Sky Air Outdoor Unit 17 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 6 Capacity tables 6 2 Heating Capacity Tables...

Page 19: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 6 Split Sky Air Outdoor Unit 18 6 Capacity tables 6 2 Heating Capacity Tables...

Page 20: ...3 1 6 Split Sky Air Outdoor Unit 19 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 6 Capacity tables 6 2 Heating Capacity Tables...

Page 21: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 6 Split Sky Air Outdoor Unit 20 6 Capacity tables 6 2 Heating Capacity Tables...

Page 22: ...3 1 6 Split Sky Air Outdoor Unit 21 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 6 Capacity tables 6 3 Capacity Correction Factor...

Page 23: ...ional Drawings 3TW34104 1 1 Gas pipe connection J15 9 flare 2 Liquid pipe connection J9 5 flare 3 Service port in the unit 4 Grounding terminal M5 in switch box 5 Refrigerant piping intake 6 Power sup...

Page 24: ...3 1 7 Split Sky Air Outdoor Unit 23 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 7 Dimensional drawings 7 1 Dimensional Drawings...

Page 25: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 8 Split Sky Air Outdoor Unit 24 8 Centre of gravity 8 1 Centre of Gravity...

Page 26: ...3 1 8 Split Sky Air Outdoor Unit 25 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 8 Centre of gravity 8 1 Centre of Gravity...

Page 27: ...Field piping J9 5 C1220T 0 Heat exchanger Filter Stop valve with service port 5 16 flare Filter Electronic expansion valve 4 way valve Compressor Service port 5 16 Heat exchanger Accumulator Outdoor u...

Page 28: ...ctronic expansion valve 4 way valve Compressor Service port 5 16 Heat exchanger Outdoor unit O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe Heati...

Page 29: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 9 Split Sky Air Outdoor Unit 28 9 Piping diagrams 9 3 Piping Diagram Triple Application...

Page 30: ...3 1 9 Split Sky Air Outdoor Unit 29 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 9 Piping diagrams 9 4 Piping Diagram Double Twin Application...

Page 31: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 10 Split Sky Air Outdoor Unit 30 10 Wiring diagrams 10 1 Wiring Diagrams Single Phase...

Page 32: ...3 1 10 Split Sky Air Outdoor Unit 31 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 10 Wiring diagrams 10 1 Wiring Diagrams Single Phase...

Page 33: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 11 Split Sky Air Outdoor Unit 32 11 Sound data 11 1 Sound Power Spectrum...

Page 34: ...3 1 11 Split Sky Air Outdoor Unit 33 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 11 Sound data 11 2 Sound Pressure Spectrum Cooling...

Page 35: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 11 Split Sky Air Outdoor Unit 34 11 Sound data 11 3 Sound Pressure Spectrum Heating...

Page 36: ...3 1 11 Split Sky Air Outdoor Unit 35 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 11 Sound data 11 4 Sound Pressure Spectrum Quiet Mode...

Page 37: ...it per row A Non stacked installation 2 Obstacles exist in front of the air inlet B Stacked installation Legend Unit mm C Multiple row installation Relation of dimensions of H A and L are shown in the...

Page 38: ...3 1 12 Split Sky Air Outdoor Unit 37 Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 12 Installation 12 1 Installation Method...

Page 39: ...Outdoor Unit Optimized for seasonal efficiency RZQSG LV1 1 12 Split Sky Air Outdoor Unit 38 12 Installation 12 1 Installation Method...

Page 40: ...pull down Indoor temp CWB Cooling Heating Indoor temp CDB Outdoor temp CWB Operation range Allowable range of operation warming up Notes Depending on operation and installation conditions the indoor u...

Page 41: ...is copyrighted by Daikin Europe N V Daikin s unique position as a manufacturer of air conditioning equipment compressors and refrigerants has led to its close involvement in environmental issues For...

Reviews: