Si00-777
Removal of Reactor / Partition Plate
Removal Procedure
29
11.Removal of Reactor / Partition Plate
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the reactor.
Preparation
Remove the sound blankets
according to "Removal of
Sound Blankets".
1
Remove the screw and
remove the reactor.
2. Remove the partition plate.
1
Remove the 2 screws.
2
Lift the partition plate
and remove it.
When reassembling, make
sure to catch the lower hook
of the partition plate.
(R14056)
(R14057)
(R14025)
Partition plate
(R5884)