Si00-777
Removal of Outdoor Fan / Fan Motor
Removal Procedure
13
5. Removal of Outdoor Fan / Fan Motor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the shield plate.
Preparation
Remove the humidifier unit
according to "Removal of
Humidifier Unit".
Be careful not to forget to
install, not to lose, and not
to break the shield plate and
the electrical box cover.
1
Remove the screw.
2
Open the fixing plate
and release the
harnesses.
3
Remove the shield
plate.
2. Remove the electrical box
cover.
1
Remove the screw.
Shield plate
(R13995)
(R5826)
(R13996)
(R5828)