10
Glossary
Operating Instructions
52
Daikin RoCon+ HP
Daikin controller RoCon+ HP1
008.1447899_00 – 09/2019 – EN
10
Glossary
Mode
Request by the user or the control unit for the function of the heat generator (e.g. room heating, domestic hot
water generation, standby, etc.)
Backup requirement
Operating situation in which the required feed temperature cannot be reached efficiently or at all using the heat
pump process. A heater booster (e.g. a backup heater) is therefore integrated to support the Daikin Altherma
ETS(X/H) in generating heat.
Backup heater
Optional electric heater booster for general support of the Daikin Altherma ETS(X/H) during heat generation.
Heating curve
Mathematical relationship between the external temperature and the feed temperature setpoint in order to
achieve the required room temperature at all external temperatures.
Refrigerant
A substance used for heat transfer in the heat pump process. At low temperature and low pressure, heat is ab-
sorbed and at high temperature and a high pressure, heat is emitted.
Anti-legionella system
Periodic heating of the storage water to >60 °C for the preventative elimination of pathogenic bacteria (so-
called legionella) in the hot water circuit.
Off-peak mains connection
(HT/NT)
A special mains connection to the energy supplier, which offers various cheaper rates during so-called low-
load periods for electrical current (day-, night-, heat pump current, etc.).
Parameters
A value that influences the execution of programs or processes or defines specific states.
Control unit
Device electronics that are used to control the processes for the heat generation and heat distribution of the
heating system. The control unit consists of a number of electronic components. The most important compon-
ent for the operator is the control panel in the front area of the heat generator, which includes program selec-
tion keys, rotary buttons and display.
Return flow
Part of the hydraulic circuit that directs the cooled water from the radiators in the rooms back to the heat gen-
erator via the piping system.
Switching time program
Program for setting the times on the control unit in order to determine the regular heating, reducing and hot
water cycles.
Smart Grid (SG)
Intelligent use of energy for inexpensive heating. By using a special electricity meter, it is possible to receive a
"Smart Grid signal" from the utility company.
Depending on the signal, the heat pump is shut off or operated as normal or at higher temperatures.
Flow
Part of the hydraulic circuit that diverts the heated water from the heat generator to the heating surfaces.
Domestic hot water circuit
This is the water circuit in which cold water is heated and diverted to the hot water tap.
Domestic hot water generation Operating status of the heat generator in which heat with elevated temperatures is generated and fed to the
hot water circuit, e.g. loading of the hot water storage tank.
Heat pump process
In a closed-loop refrigerant circuit, the refrigerant absorbs the heat from the ambient air. By means of com-
pression, the refrigerant achieves a higher temperature that is transferred to the heating system (thermody-
namic cycle).
Heat exchanger
A component that transfers thermal energy from one circuit to another. The two circuits are hydraulically sep-
arated from one another by a wall in the heat exchanger.
Weather-dependent feed tem-
perature control
A suitable feed temperature is determined from the measured value for the external temperature and a defined
heating curve; this temperature is used as the target value for temperature control in the heating unit.
Circulation pump
The circulation pump is an additional electrical circulation pump that permanently circulates the hot water in
the hot water lines, thus providing it immediately at every tap. This circulation is especially useful in extensive
pipeline networks. In systems without a circulation line, first the water cooled in the sampling line escapes dur-
ing the sampling process until the sampling line has been sufficiently heated by the inflowing hot water.
Heater booster
Additional heat generator (e.g. backup heater or external boiler) integrated in the heating system to achieve
the required feed temperature setpoint in the case of an inadequate or inefficient heat pump process.
Summary of Contents for RoCon+ HP Series
Page 116: ...Betriebsanleitung 116 Daikin RoCon HP Daikin Regelung RoCon HP1 008 1447899_00 09 2019 DE ...
Page 236: ...Gebruiksaanwijzing 236 Daikin RoCon HP Daikin regeling RoCon HP1 008 1447899_00 09 2019 NL ...
Page 351: ...Driftsvejledning 351 Daikin RoCon HP Daikin regulering RoCon HP1 008 1447899_00 09 2019 DA ...
Page 406: ...Instruktionsbok 406 Daikin RoCon HP Daikin reglerenhet RoCon HP1 008 1447899_00 09 2019 SV ...
Page 460: ...Brukerveiledning 460 Daikin RoCon HP Daikin Regulering RoCon HP1 008 1447899_00 09 2019 NO ...
Page 516: ...008 1447899_00 09 2019 EN DE FR NL IT DA SV NO FI Copyright Daikin ...