7
Parameter settings
Operating Instructions
46
Daikin RoCon+ HP
Daikin controller RoCon+ HP1
008.1447899_00 – 09/2019 – EN
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE
HF
Ext. energy
source, heat-
ing
-
The volume of heat of the additional heat generator for heating mode in
kWh is displayed.
-
kWh
S
S
Runtime, com-
pressor
-
The running time of the refrigerant compressor in h is displayed.
-
1 h
S
S
Runtime,
pump
-
The runtime of the internal heating circulation pump is displayed in h.
-
1 h
S
S
Reset
-
All parameters listed in the Statistics menu are reset to "0". (Specialist
code required).
-
-
Tab. 7-24
Parameter in the "Statistics" menu
INFORMATION
Depending on the device type, the system configuration
and the status of the device software, individual listed in-
formation parameters cannot be displayed or can be dis-
played at a different parameter level.
7.11
Configuration wizard
Only after hardware reset.
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE
HF
Direct circuit
configuration
0 – 15
Setting of the heating circuit ID for the direct heating circuit of the Daikin
Altherma ETS(X/H). The heating circuit ID must be unique throughout the
entire RoCon system. There must be no overlap with the HC IDs of op-
tional mixer circuits.
0
1
N
E
Bus ID heat
generator
0 – 7
The setting must not be changed if more than 1 heat generator is integ-
rated in the RoCon system. Several heat generators integrated in the heat-
ing system must be regarded as a special application. If necessary, contact
a service technician.
0
1
N
E
Time master
No
Activation of a system-wide time master. The time master synchronises all
controllers in the RoCon system with the time and date set on the time
master. For all other control panels in the system, it is no longer possible to
enter the time and date. There must only be one time master in the entire
system. The parameter is not available if the time master parameter is ac-
tivated on another controller in the RoCon system.
-
N
E
Yes
Tab. 7-25
Parameter in the "Configuration Wizard" menu
Summary of Contents for RoCon+ HP Series
Page 116: ...Betriebsanleitung 116 Daikin RoCon HP Daikin Regelung RoCon HP1 008 1447899_00 09 2019 DE ...
Page 236: ...Gebruiksaanwijzing 236 Daikin RoCon HP Daikin regeling RoCon HP1 008 1447899_00 09 2019 NL ...
Page 351: ...Driftsvejledning 351 Daikin RoCon HP Daikin regulering RoCon HP1 008 1447899_00 09 2019 DA ...
Page 406: ...Instruktionsbok 406 Daikin RoCon HP Daikin reglerenhet RoCon HP1 008 1447899_00 09 2019 SV ...
Page 460: ...Brukerveiledning 460 Daikin RoCon HP Daikin Regulering RoCon HP1 008 1447899_00 09 2019 NO ...
Page 516: ...008 1447899_00 09 2019 EN DE FR NL IT DA SV NO FI Copyright Daikin ...