![Daikin RMXS-L Series Service Manual Download Page 34](http://html1.mh-extra.com/html/daikin/rmxs-l-series/rmxs-l-series_service-manual_4185750034.webp)
SiUS181305E
Indoor Unit
Printed Circuit Board Connector Wiring Diagram
24
3.4
FDXS09/12LVJU, CDXS15/18/24LVJU
Control PCB
Caution
Replace the PCB if you accidentally cut the jumpers other than JA, JB, and JC.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
1) S1
Connector for AC fan motor
2) S7
Connector for AC fan motor (Hall IC)
3) S21
Connector for centralized control (HA)
4) S26
Connector for display PCB
5) S32
Connector for indoor heat exchanger thermistor
6) H1, H2, H3
Connector for terminal board
7) FG (GND)
Connector for terminal board (ground)
8) JA
Address setting jumper
9) JB
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function (auto-restart)
10) LED A
LED for service monitor (green)
11) FU1 (F1U)
Fuse (3.15 A, 250 V)
12) V1
Varistor
H2
H1
H3
FG
JB
S21
2P292535-1
LED A
JC
JA
S7
S1
FU1
S26
V1
S32