Si001274EC
PCBs
Removal Procedure
13
4. PCBs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Remove the main PCB.
[S12]: for [HL4] [HN4] on filter
PCB
1
Disconnect the
connector [S12] and
pull out the clamp.
2
Disconnect the
connector [S10].
[S10]: for [S11] on filter PCB
3
Pull out the clamp.
When reassembling, insert
the clamp as below.
(R16959)
[S12]
Main PCB
(R16808)
[S10]
(R16775)
(R20195)
For compressor harness
(red, blue, yellow)