SiUS372201EA
Troubleshooting by Error Code
Part 6 Service Diagnosis
370
3.53 Inverter PCB Abnormality
Applicable
Models
All outdoor unit models
Error Code
L1
Method of Error
Detection
Detect current value during the output of waveform before compressor startup
Detect current value with the current sensor during synchronous operation for startup
Error Decision
Conditions
When the overcurrent flows during the output of waveform
When the current sensor error during synchronous operation
When IPM error occurs
Supposed
Causes
Inverter PCB
IPM failure
Current sensor failure
Drive circuit failure