
Outline of Control (Indoor Unit)
SiUS372201EA
157
Part 4 Functions and Control
9. Outline of Control (Indoor Unit)
9.1 Operation Flowchart
Is
test r
u
n in
progress?
Is freeze-
u
p pre
v
ention operation in
progress?
Is
Restart pre
v
ention
operation in progress?
(5 min.)
De
w
pre
v
ention condition?
Is the
safety de
v
ice
acti
v
ated?
Start
Heating Operation
Fan Operation
Cooling Operation
Cooling Operation
Detect lo
uv
er lock
( )
R
u
n or Stop?
RU
N
indicating lamp: OFF
RU
N
indicating lamp: Blink
Error code: Displayed
RU
N
indicating lamp: OFF
Error mode display: Reset
Thermostat stat
u
s
S
w
ing flap
S
w
ing flap
Set
w
ind direction
Program dry display: Reset
Program dry operation
A
A
A
Stop
R
u
n
Yes
Yes
Yes
Yes
Yes
Yes
N
o
N
o
N
o
N
o
O
N
OFF
N
o
N
o
N
o
∗
1
Fan
Temp. control
Heating
Cooling
∗
2 Fan : Stop
Lo
uv
er : Stop
∗
3
∗
4
∗
7
∗
4
∗
6
∗
5
(Option)
OFF
O
N
MF
MF
: OFF
MP
Drain p
u
mp kit
MP
Drain p
u
mp kit
MP
Drain p
u
mp kit
:O
N
MP
Drain p
u
mp kit
: O
N
MP
: Closed
Electronic expansion
v
al
v
e
: Capacity control
Electronic expansion
v
al
v
e
: Closed
YE
MA
: OFF
EH
: OFF
EH
H
u
midifier : OFF
H
u
H
u
midifier : OFF
H
u
YE
The pre
v
io
u
s settings of airflo
w
rate,
w
ind direction, and
temperat
u
re are displayed.
Is the RU
N
indicating lamp
b
linking?
Press the RESET
RU
N
/STOP p
u
sh
bu
tton.
Electronic
expansion
v
al
v
e
Thermostat-O
N
-
operation signal to
o
u
tdoor
u
nit: O
u
tp
u
t
Thermostat-O
N
-
operation signal to
o
u
tdoor
u
nit: O
u
tp
u
t
RU
N
indicating lamp: O
N
Airflo
w
rate display: Displayed
W
ind direction display: Displayed
Temp. setting display: Displayed
T
u
rn O
N
po
w
er s
u
pply
Initialize electronic
expansion
v
al
v
e
LED in remote
controller t
u
rns O
N
Cyclic operation
w
ith
RU
N
/STOP p
u
sh
bu
tton
Fan or Temp.
control?
Cooling or
Heating?
Drain
p
u
mp kit
A
u
x. electric
heater
A
u
x. electric
heater
De
w
pre
v
ention position
Cassette type: P1
Ceiling s
u
spended type: P0
Program dry
O
N
/OFF
Fan:
Operating
w
ith set airflo
w
rate
: OFF after 5-min.
resid
u
al operation
: OFF after 5-min.
resid
u
al operation
Yes
YE
YE
Summary of Contents for REYQ-AATJA
Page 1: ...Service Manual Heat Recovery 60 Hz REYQ AATJA 208 230 V REYQ AAYDA 460 V SiUS372201EA...
Page 465: ...SiUS372201EA Wiring Diagrams Part 7 Appendix 458 BS6 8Q54TVJ 2D089122B...
Page 466: ...Wiring Diagrams SiUS372201EA 459 Part 7 Appendix BS10 12Q54TVJ 2D089121B...
Page 469: ...SiUS372201EA Wiring Diagrams Part 7 Appendix 462 BSF6 8Q54TVJ 2D123905A...
Page 472: ...Wiring Diagrams SiUS372201EA 465 Part 7 Appendix FXZQ05 07 09 12 15 18TAVJU 3D110443A...
Page 476: ...Wiring Diagrams SiUS372201EA 469 Part 7 Appendix FXEQ07 09 12 15 18 24PVJU 3D098557A...
Page 477: ...SiUS372201EA Wiring Diagrams Part 7 Appendix 470 FXDQ07 09 12 18 24MVJU C 3D050501C...
Page 483: ...SiUS372201EA Wiring Diagrams Part 7 Appendix 476 FXHQ12 24 36MVJU 3D048116C...
Page 484: ...Wiring Diagrams SiUS372201EA 477 Part 7 Appendix FXAQ07 09 12 18 24PVJU 3D075354F...
Page 490: ...Wiring Diagrams SiUS372201EA 483 Part 7 Appendix VAM1200GVJU 3D073270D...