Outline of Control (Outdoor Unit) < Symbols using in this manual >
Function R407C PLUS Series Heat Recovery System
49
3. Outline of Control (Outdoor Unit)
< Symbols using in this manual >
Apparatus No.
Symbol
Description
Y3S
20RH
Discharge solenoid valve of BS unit
Y2S
20RL
Suction solenoid valve of BS unit
Y1S
20RT
Bypass solenoid valve of BS unit (liquid)
Y1R
20S1
4 way valve 1
Y2R
20S2
4 way valve 2
Y3R
20S3
4 way valve 3
52Ci
Magnetic switch for INV compressor
DSH
Discharge superheat
DSHi
Discharge superheat of INV compressor
EV
Electronic expansion valve
Y1E
EV1
Electronic expansion valve of Heat EX.1
Y2E
EV2
Electronic expansion valve of Heat EX.2
Y3E
EV3
Electronic expansion valve of sub unit heat EX.
HDSHi
Adjusted discharge superheat of INV compressor
HDSHs1
Adjusted discharge superheat of STD1 compressor
HDSHs2
Adjusted discharge superheat of STD2 compressor
SENPH
Hp
High pressure
HTdi
Adjusted discharge pipe temperature of INV compressor
HTds1
Adjusted discharge pipe temperature of STD1 compressor
HTds2
Adjusted discharge pipe temperature of STD2 compressor
SENPL
Lp
Low pressure
SENPH
Pc
Condensing pressure
SENPL
Pe
Evaporating pressure
SH
Superheat
SHS
Target evaporator outlet superheat
Y2S
SVP
Bypass solenoid valve
Y1S
SVS
Solenoid valve for auxiliary condensor
Y3S
SVTi
Solenoid valve for INV comp. liquid injection
Y4S
SVRVG
Solenoid valve for liquid receiver
Y5S
—
Solenoid valve for liquid pressure control
Y6S
SVTs1
Solenoid valve for STD1 comp. liquid injection
Y7S
SVTs2
Solenoid valve for STD2 comp. liquid injection
R1T
Ta
Ambient temperature
R21T
Tb1
Heat exchanger 1 distributor temperature
R22T
Tb2
Heat exchanger 2 distributor temperature
R23T
Tb3
Heat exchanger 3 distributor temperature
Tc
High pressure equivalent saturation temperature
Tcg
High pressure equivalent saturation temperature (gas side)
Tcl
High pressure equivalent saturation temperature (liquid side)
Tcs
Target Tc value
Td
Discharge pipe temperature
R31T
Tdi
Discharge temperature of INV compressor
R32T
Tds1
Discharge temperature of STD1 compressor
R33T
Tds2
Discharge temperature of STD2 compressor
Te
Low pressure equivalent saturation temperature
TeS
Target Te value
T fin
Inverter unit fin temperature
R1T
Th1
Ambient temperature
R21, 22, 23T
Th2
Heat exchange distributer temperature
R31T
Th3-11
Discharge pipe temperature for INV compressor
R32, R33T
Th3-12, 13
Discharge pipe temperature for STD1, 2 compressor
R41, 42, 43T
Th4-11, 12, 13
Heat exchanger suction pipe temperature
R6T
Th7
Accumulator outlet temperature
R8T
Th8
Receiver outlet temperature
R6T
Trac
Accumulator outlet temperature
R8T
Trev
Receiver outlet temperature (liquid)
R41T
Ts1
Heat exchanger 1 suction pipe temperature
R42T
Ts2
Heat exchanger 2 suction pipe temperature
R43T
Ts3
Heat exchanger 3 suction pipe temperature
Summary of Contents for R407C PLUS
Page 1: ...System R407C PLUS Series Heat Recovery System Si33 105 Service Manual ...
Page 11: ...Introduction Si33 105 x ...
Page 41: ...Specifications Si33 105 30 Specifications R407C PLUS Series Heat Recovery System ...
Page 147: ...Test Operation Si33 105 136 Test Operation R407C PLUS Series Heat Recovery System ...
Page 263: ...Si33 105 iv Index ...