4 Operation
Operation manual
6
FTXP20~35M5V1B
R32 split series
3P520336-6B – 2018.12
Setting
Airflow direction
Vertical automatic
swing
Moves up and down.
Horizontal
automatic swing
Moves from side to side.
+
3-D airflow
direction
Moves simultaneously up and down and
from side to side
[—]
Stays in a fixed position.
CAUTION
▪ ALWAYS use a user interface to adjust the position of
the flaps and louvers. When the flaps and louvers are
swinging and you move them forcibly by hand, the
mechanism will break.
The movable range of the flap varies according to the operation
mode. The flap will stop at the upper position when the airflow rate is
changed to low during the up and down swing setting.
To adjust the airflow direction
1
To use auto swing, press .
Result:
will appear on the LCD.
Result:
The flap (horizontal blade) will begin to swing.
2
To use fixed position, press when the flap reaches the desired
position.
Result:
disappears from the LCD.
To adjust the louvers (vertical blades)
4.3.4
Comfort airflow operation
This operation can be used in
heating
or
cooling
operation mode. It
will provide a comfortable wind that will NOT come in direct contact
with people. The system automatically sets the fixed airflow position
upward in Cooling and downward in Heating operation mode.
Cooling operation mode
Heating operation mode
INFORMATION
Powerful and Comfort airflow operation CANNOT be used
at the same time. The last selected function takes priority.
If the vertical automatic swing is selected, Comfort airflow
operation will be cancelled.
To start/stop Comfort airflow operation
1
Press to start.
Result:
The flap position will change,
is displayed on the
LCD, and the airflow rate is set to automatic.
Mode
Position of flap…
Cooling/Drying
Up
Heating
Down
2
Press to stop.
Result:
The flap will return to the position from before the Comfort
airflow mode;
disappears from the LCD.
4.3.5
Powerful operation
This operation quickly maximizes the cooling/heating effect in any
operation mode. You can get the maximum capacity.
INFORMATION
Powerful operation CANNOT be used together with Econo
and Comfort airflow operation. The last selected function
takes priority.
Powerful operation will NOT increase the capacity of the
unit if it already operates at maximum capacity.
To start/stop Powerful operation
1
Press to start.
Result:
is displayed on the LCD. Powerful operation runs
for 20 minutes; after that, operation returns to the previously set
mode.
2
Press to stop.
Result:
disappears from the LCD.
Note:
Powerful operation can be set only when the unit is running. If
you press
, operation will be cancelled;
disappears from
the LCD.
4.3.6
Econo operation
This is a function which enables efficient operation by limiting the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.
INFORMATION
▪ Powerful and Econo operation CANNOT be used at the
same time. The last selected function takes priority.
▪ Econo operation reduces power consumption of the
outdoor unit by limiting the rotation speed of the
compressor. If power consumption is already low,
Econo operation will NOT further reduce power
consumption.
To start/stop Econo operation
1
Press to start.
Result:
is displayed on the LCD.
2
Press to stop.
Result:
disappears from the LCD.
a
A
B
b
c
d
A
Running current and power consumption
B
Time
a
Maximum during normal operation
b
Maximum during Econo operation
c
Normal operation
d
Econo operation
▪ The diagram can be used for illustrative purposes only.
▪ The maximum running current and power consumption of the air
conditioner in Econo operation varies with the connected outdoor
unit.