background image

REMOVAL

PROCEDURE

S E R V I C E   M A N U A L

Outdoor Unit

Non-inverter

Pair Type

2.5/3.5 kW Class
9000/12000 Btu/h Class

Si011083

Summary of Contents for R25GV1G6

Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L Outdoor Unit Non inverter Pair Type 2 5 3 5 kW Class 9000 12000 Btu h Class Si011083...

Page 2: ...Service Manual Removal Procedure Outdoor Unit zCooling Only R25GV1G6 R35GV1G6 RE09LV2S RE12LV2S...

Page 3: ...1 Table of Contents 1 Removal of Outer Panels Fan Motor 2 2 Removal of Electrical Components ASSY 8 3 Removal of Sound Blanket 9 4 Removal of Compressor 10 Note The illustrations may be slightly diffe...

Page 4: ...g work Step Procedure Points 1 External appearance Take care not to cut your finger by the fins of the outdoor heat exchanger 2 Remove the panels The stop valve cover is united with the shield plate W...

Page 5: ...ews and remove the top panel 3 Remove the 4 screws and remove the discharge grille The discharge grille has 4 hooks 4 Remove the 8 screws and remove the front panel Step Procedure Points DAIKIN INVERT...

Page 6: ...M6 1 Remove the nut of the outdoor fan 2 Remove the outdoor fan When reassembling align the mark of the outdoor fan with the D cut section of the motor shaft 3 Disconnect the connector for the fan mo...

Page 7: ...n motor lead wire through the back of the fan motor when reassembling so as not to be entangled with the outdoor fan 5 Remove the 4 screws and remove the fan motor 6 Remove the screw and remove the fa...

Page 8: ...6 Removal Procedure When reassembling fit the lower hooks into the bottom frame 4 Remove the right side panel 1 Lift up and remove the guard net 2 Remove the 2 screws on the rear side Step Procedure...

Page 9: ...e 7 3 Remove the 4 screws on the right side 4 Remove the screw near the connection port 5 Unfasten the hook When reassembling make sure to fit the hook 6 Lift up the right side panel and remove it Ste...

Page 10: ...Step Procedure Points 1 Remove the nut and remove the terminal cover Preparation Remove the outer panels and disconnect the connector for the fan motor according to the Removal of Outer Panels Fan Mo...

Page 11: ...Procedure Points 1 Untie the strings and open the sound blanket Preparation Remove the outer panels according to the Removal of Outer Panels Fan Motor Remove the electrical components ASSY according...

Page 12: ...t discharge the refrigerant gas in the atmosphere Make sure to collect all the refrigerant gas Cautions for restoration 1 Restore the piping by non oxidation brazing 2 It is required to prevent the ca...

Page 13: ...the sawdust comes into the circuit When withdrawing the pipes be careful not to pinch them firmly with pliers The pipes may get deformed Provide a protective sheet or a steel plate so that the brazin...

Page 14: ...Revision History Month Year Version Revised contents 01 2013 Si011083 First edition...

Page 15: ...ies supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acces...

Reviews: