4
|
Components
Service manual
147
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
4
Route the DC fan motor harness upwards and attach the DC fan motor
harness to the switch box.
5
Connect the DC fan motor connector to the connector on the main PCB.
6
Install the propeller fan blade assembly, see
145].
To install the propeller fan blade assembly
1
Install the propeller fan blade assembly on the DC fan motor assembly.
CAUTION
Do NOT install a damaged propeller fan blade assembly.
2
Install and tighten the nut to fix the propeller fan blade assembly.
a
b
a
Nut
b
Propeller fan blade assembly
Is the problem solved?
Action
Yes
No further actions required.
No
Return to
143] of the outdoor unit
fan motor and continue with the next
procedure.
4.13.2 Class 42~71 units
Checking procedures
INFORMATION
It is recommended to perform the checks in the listed order.
To perform a mechanical check of the propeller fan blade assembly
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
If propeller fan blade touches the bell mounth, check if the fan motor is
correctly mounted on its base, see