![Daikin Perfera RXM20R Service Manual Download Page 117](http://html1.mh-extra.com/html/daikin/perfera-rxm20r/perfera-rxm20r_service-manual_4700072117.webp)
4
|
Components
Service manual
117
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
4.10.2 Repair procedures
To correct the wiring from the indoor unit power supply terminal to the indoor unit power PCB
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Correct the wiring from the indoor unit power supply terminal to the indoor
unit power PCB, see
Is the problem solved?
Action
Yes
No further actions required.
No
Return to
106] of the indoor unit
power PCB and continue with the next
procedure.
To remove the indoor unit power PCB
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Disconnect all connectors from the indoor unit power PCB.
2
Carefully click the indoor unit power PCB out of the PCB retainers.
a
A
A
Wall mounted indoor unit
a
Indoor unit power PCB