1
Cut off the slit portion using nippers.
2
Remove an burrs along the cut section using a half round needle file.
6.3.4 To provide drainage
Make sure condensation water can be evacuated properly. This involves:
▪
General guidelines
▪
Connecting the drain piping to the indoor unit
▪
Checking for water leaks
General guidelines
▪
Pipe length.
Keep drain piping as short as possible.
▪
Pipe size.
Use rigid polyvinyl chloride pipe with 20 mm nominal diameter and
26 mm outer diameter.
NOTICE
▪
Install the drain hose with a downward slope.
▪
Traps are NOT permitted.
▪
Do NOT put the end of the hose in water.