3
|
Components
Service manual
106
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
3.9.2 Repair procedures
To remove the indoor unit main PCB
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
151].
1
Disconnect all connectors from the indoor unit main PCB.
2
Carefully click the indoor unit main PCB out of the PCB retainers.
a
A
A
Wall mounted indoor unit
a
Indoor unit main PCB
a
A
A
Floor standing indoor unit
a
Indoor unit main PCB