WARNING

!

CAUTION

Installation and maintenance should be performed by qualifi ed 

persons who are familiar with local code and regulation, and 

experienced with this type of appliance.

Confi rm

 

that the unit has been switched OFF before 

installing or servicing the unit.

Risk of electric shock, can cause injury or death. Disconnect all 

remain electric power supplies before servicing.

DO NOT pull out the power cord when the power is ON. 

This may cause serious electrical shocks which may result 

in 

fire

 hazards.

Please take note of the following important points when 

installing.

 

Improper connection or fastening can 

 cause fire or electrical shock.

Do not handle with wet hands/ wash the unit with water.

  Electrical shock may occur.

Do not operate any heating apparatus too close to the 

gateway or use in room where mineral oil, oil vapor or oil 

steam  exist,  this  may  cause  plastic  part  to  melt  or 

deform as a result of excessive heat or chemical reaction. 

Don’t  use  joined  and  twisted  wires  for  incoming power 

supply.

The  equipment  is  not  intended  for  use  in  a potentially 

explosive atmosphere.

SAFETY PRECAUTIONS

INSTALLATION MANUAL

This manual provides the procedures of installation to ensure a safe and good standard of 

operation for the 

Netpro Dual

. Special adjustment may be necessary to suit local requirement.

Before using your gateway, please read this instruction manual carefully and keep it for future 

reference. 

This appliance is intended to be used by expert or trained users in shop

ping mall

, in light 

industry and 

office building

 or for commercial use by lay persons.

This appliance is not intended for use by persons, including children, with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the appliance by a person responsible for their 

safety.

Children should be supervised to ensure that they do not play with the appliance.

Do not install the unit where leakage of flammable gas 

Use  only  the  recommended  cables  for  wiring.  The

 

connections  must  be  firm  but  without  tensioning

 

the terminals.

Summary of Contents for NetPro Dual

Page 1: ...English INSTALLATION OPERATION MANUAL Installation Operation Manual NetPro Dual NetPro Dual...

Page 2: ...CONTENTS...

Page 3: ...INSTALLATION MANUAL NetPro Dual Installation Manual NetPro Dual CVR IM 5WMYJ 0113 2 DAIKIN EN in1 1 CVR IM 5WMYJ 0113 2 DAIKIN EN in1 1 6 9 14 3 57 00 PM 6 9 14 3 57 00 PM English...

Page 4: ...K BAG 33 5 118 4 183 4 33 5 46 0 154 0 1 5 43 0 114 0 1 5 179 0 OUTLINE AND DIMENSIONS Original Instruction TOP VIEW SIDE VIEW FRONT VIEW 1 IM 5WMYJ 0113 2 DAIKIN_EN indd1 1 1 IM 5WMYJ 0113 2 DAIKIN_E...

Page 5: ...s a result of excessive heat or chemical reaction Don t use joined and twisted wires for incoming power supply The equipment is not intended for use in a potentially explosive atmosphere SAFETY PRECAU...

Page 6: ...ng screws 4pcs Should you find packaging is tempered please contact authorized sales office Interface SLM8 BRC51A SQSLM8 BRC51A64 SLM9 SQSLM9 SHIRO SQLCD SQSHIRO with RS 485 None of the interface abov...

Page 7: ...tion to BNG and Modbus Master Connector for connection to SLM8 BRC51A SQSLM8 BRC51A64 SLM9 SQSLM9 SHIRO Connector for connection to mainboard controller Sequential type mainboard controller with RS 48...

Page 8: ...etting Dip Switch DIP_Unit UNIT CONFIGURATION Adjusting the dip switch to ON position enables the function assigned to it Configure the Option Setting Dip Switch DIP_Option according to operating opti...

Page 9: ...English UNIT CONFIGURATION Refer to the table below for DIP_NETWORK setting up to 20 units 6...

Page 10: ...English UNIT CONFIGURATION 7...

Page 11: ...ainboard controller and wired panel SQMB with RS 485 Make connections from TB_MB NetPro Dual to TB_WIR SQMB accordingly A to A B to B 5V to 5V GND to GND Note that 12V on NetPro Dual to be connected t...

Page 12: ...arness wires to the connector CN_MB on NetPro Dual and plug the other end of the wire to CN_WIR on mainboard controller Mainboard without RS485 CN_WIR NetPro Dual CN_MB SHIRO SLM8 without RS485 CN _WI...

Page 13: ...posed to direct sunlight Susceptible to humidity and moisture Near to heat source Near to machines that emits high frequency wave Near to high current switching devices Caution Over tightening the scr...

Page 14: ...M 5WMYJ 0113 2 DAIKIN_EN indd11 11 1 IM 5WMYJ 0113 2 DAIKIN_EN indd11 11 6 10 14 10 07 25 AM 6 10 14 10 07 25 AM English RECOMMENDED WIRE SPECIFICATION Recommended wire specification and maximum wire...

Page 15: ...ntact Outputs Input Output Type Dry Contact Outputs Maximum Electrical Ratings 24VDC 100mA 240VAC 3A Input Output Name On Off Heat Cool or Dry or Fan Unit Faulty ELECTRICAL CHARACTERISTIC English Wiri...

Page 16: ...English CVR OM SLM9 0911 1 DAIKIN EN ind1 1 CVR OM SLM9 0911 1 DAIKIN EN ind1 1 5 6 14 9 56 15 AM 5 6 14 9 56 15 AM OPERATION MANUAL NetPro Dual Operation Manual NetPro Dual...

Page 17: ...trolling and operating parameters NetPro Dual Modbus Mode is designed to integrate the air conditioner system with the network system through RS485 communication Modbus Control can be performed by set...

Page 18: ...Y2 Y3 Dry Contact Contact Contact CLOSED Unit On Heat Unit Faulty Function On Off Operating Mode Unit Error Indicator OPEN Unit Off Cool Dry Fan Normal Please refer to the documents MODBUS Protocol V...

Page 19: ...1 OM SLM9 0911 1 DAIKIN EN indd 7 1 OM SLM9 0911 1 DAIKIN EN indd 7 5 6 14 9 57 09 AM 5 6 14 9 57 09 AM MEMO ENGLISH 15...

Reviews: