background image

2

Daikin

 IM 1019

Installation Instructions   . . . . . . . . . . . . . . . . . . . . . . . 3

Applications and features   . . . . . . . . . . . . . . . . . . . . . 3
Specifications   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Thermostat Model and Part Number  . . . . . . . . . . . . . 4
Optional Sensors/Kits  . . . . . . . . . . . . . . . . . . . . . . . . 4
Installing, Mounting and Wiring the Thermostat   . . . . 4

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Front Panel Reference   . . . . . . . . . . . . . . . . . . . . . . . 6
Display Reference  . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Saving Changes   . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Up/Down Arrow Button Operation  . . . . . . . . . . . . . . . 7
System Button Operation   . . . . . . . . . . . . . . . . . . . . . 8
Fan Button Operation   . . . . . . . . . . . . . . . . . . . . . . . . 8
Program Button Operation   . . . . . . . . . . . . . . . . . . . . 8

Function Overview   . . . . . . . . . . . . . . . . . . . . . . . . 8
Setting the Clock & Day   . . . . . . . . . . . . . . . . . . . . 9
Setting the Temperature Display . . . . . . . . . . . . .   9
Programming Time & Temperature Settings   . . . . 9
Overriding the Program . . . . . . . . . . . . . . . . . . . . 10

System Check-out  . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Condensate Overflow Interrupt  . . . . . . . . . . . . . . . . 11
Thermostat configuration/ Service Menu   . . . . . . . . 11

Technical and Application Notes  . . . . . . . . . . . . . .  12

Fan Operation   . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

Standard Fan Operation   . . . . . . . . . . . . . . . . . .  12
Staged Fan Operation with 
Temperature Demand  . . . . . . . . . . . . . . . . . . . .  12

Fancoil Operation . . . . . . . . . . . . . . . . . . . . . . . . . .  12

Pipe Sensor Operation   . . . . . . . . . . . . . . . . . . .  12
Purge Cycle Operation   . . . . . . . . . . . . . . . . . . .  12

HVACSetback Systems  . . . . . . . . . . . . . . . . . . . . .  13

Setback Operation - Remove JP3  . . . . . . . . . . .  13
Door Switch Only Operation - Install JP3   . . . . .  13

Optional Occupancy Detection 
Equipment Operation . . . . . . . . . . . . . . . . . . . . . . . .  14

Occupancy Operation (Install JP3)   . . . . . . . . . . . .  14

Operation From an Occupied Mode   . . . . . . . . .  14
Operation From an Unoccupied Mode . . . . . . . .  14

SB200-001 Occupancy Sensor  . . . . . . . . . . . . . . .  14

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14

SD200-001 Occupancy Sensor  . . . . . . . . . . . . . . .  15

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

SD200-002 Occupancy Sensor  . . . . . . . . . . . . . . .  15

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

Annex I   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16

Annex II  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

Summary of Contents for MT 180

Page 1: ...Installation and Maintenance Manual IM 1019 Group Fan Coil Part Number IM 1019 Date October 2011 2011 Daikin MT 180 Programmable Thermostat...

Page 2: ...Program 10 System Check out 11 Condensate Overflow Interrupt 11 Thermostat configuration Service Menu 11 Technical and Application Notes 12 Fan Operation 12 Standard Fan Operation 12 Staged Fan Opera...

Page 3: ...installing this control the Voltage Selection Switch must be placed in the correct position See instructions To avoid potential fire and or explosion do not use in potentially flammable or explosive...

Page 4: ...n offers two different 7 Day Programmable Digital Heating Cooling Thermostat with constant fan or Fan cycled On Off Valve Control depending on the fan speed control used See Table 2 Table 2 Thermostat...

Page 5: ...s for further information on Pipe Sensor Operation page 12 2 Pipe Operation Install JP4 The thermostat will per manently disable the Secondary Output and disables sys tem and fan invalid modes 4 Pipe...

Page 6: ...off the entire system SETBACK Indicates the heating or cooling system is operating in setback mode Setback mode is an energy saving feature that can be either manually activated by the thermostat s u...

Page 7: ...o the ther mostat s default display Up Down Arrow Button Operation The and buttons function in two ways When you are in the default display you can press to increase or to decrease the current tempera...

Page 8: ...e factory default or installer selected during installation During setback mode when a demand for heating or cooling exists the fan will run at the lowest speed Automatic setback mode If your thermost...

Page 9: ...ctory program meets your needs simply follow the Setting the Clock Day instructions and you re done If you want to change the preprogrammed times and or temperatures follow the instructions under Cust...

Page 10: ...ect DAY Program the Evening period for SASU by repeating steps 1 through 8 but in Step 4 select EVE Program the Sleep period for SASU by repeating steps 1 through 8 but in Step 4 select SLEEP Now you...

Page 11: ...terrupt The remote probe input can be used with a condensate overflow interrupt switch CO either in conjunction with a remote probe normally closed CO switch or with local sensing normally open CO swi...

Page 12: ...a purge cycle if the sensed water temperature is ambiguous not adequately hot or cold The purge cycle algorithm can be either temperature or time based depending on the configuration of Service Menu...

Page 13: ...stat outputs are disabled for 1 hour After 1 hour the purge cycle resumes at step 1 HVACSetback Systems Setback Operation Remove JP3 This is a low level input that is normally open When switch is clos...

Page 14: ...trol of a guest room HVAC system It incorporates an innovative dual delay processor which allows the sensor to verify the nature of occupancies and is capable of eliminating unnecessary actuations of...

Page 15: ...cy status detection If the sensor determines that a room is occupied it will allow normal HVAC control The sensor will wait for another door open signal before determining occupancy again In an unoccu...

Page 16: ...d Start Time Heat Setpoint Temperature Cool Setpoint Temperature Monday Wake Day Evening Sleep Tuesday Wake Day Evening Sleep Wednesday Wake Day Evening Sleep Thursday Wake Day Evening Sleep Friday Wa...

Page 17: ...urge Cycle 0 Time Based Default 1 Temperature Based Determines if the Purge Cycle will be Temperature or Time Based 17 Minimum Dead Band Adjustment 3 F Default 3 10 F 1 5 5 C A changeover deadband val...

Page 18: ...Training Department Warranty All Daikin equipment is sold pursuant to its standard terms and conditions of sale including Limited Product Warranty Consult your local Daikin Representative for warranty...

Reviews: