background image

5

Read First

Precautions During Use

About streamer discharge and active plasma ions

In some cases the air outlet may emit a slight odour as 
trace amounts of ozone are generated. However, the 
amount is negligible and is not harmful to your health.

•  This product cannot eliminate all of the toxic 

substances in tobacco smoke (carbon monoxide etc.)

•  Odours cannot be completely removed if they are 

being constantly generated (building material odours, 

pet odours, etc.)

Other considerations

„

Do not use this product for special purposes such 

as in the preservation of works of art, academic 

texts/materials, etc.

(Degradation of preserved items may result)

„

Do not excessively humidify the air.

(Condensation and mould growth may result)

„

Do not use any of the following types of liquid.

Warm water (40ºC or above), aroma oil, chemical agents 

such as hypochlorous acid, unclean water, water 

containing aromatic substances or detergent, etc.

(Deformation of the unit or malfunction may result)

Water from a water purifi er, ionized alkaline water, 

mineral water, well-water etc. 

(Propagation of mould or bacteria may result)

„

Be careful of freezing.

(Malfunction may result)
Discard any water in the water tank and humidifying tray 
if there is any risk of freezing.

„

When not using the Humidifying operation, discard 

any water in the water tank and humidifying tray.

(Bad odours may result from the propagation of mould 
or bacteria in dirt and water scales)

„

Depending on the usage environment, shorten the 

maintenance period. When using in places with high 

foot traffi c such as hotels and public facilities, 

shorten the pre-fi lter maintenance period.

(If the pre-fi lter becomes clogged and the unit continues 
to be used, malfunction may result)

Do not use in the following places

„

Positions from where out fl owing air fl ows directly 

at a wall, furniture, curtains, etc.

(Staining or deformation may result)

„

On top of a thick carpet, bed cover or mattress

The unit may tilt causing water to spill or the water level 
sensor may fail to work correctly.

„

Places exposed to direct sunlight

(Discolouration may result)

„

Places exposed to outdoor air (e.g. near windows, 

etc.) or direct airfl ow from air conditioners, etc.

Room humidity may not be detected and indicated 
correctly.

„

Positions near combustion-based heating devices 

or exposed to direct airfl ow from heating appliances

(Room humidity may not be detected and indicated 
correctly or deformation may result)

„

Places where chemicals and pharmaceuticals are 

used such as hospitals, factories, laboratories, 

beauty salons, and photographic laboratories

(Volatilized chemicals and solvents may degrade 
mechanical parts, cause water leaks and cause things 
to get wet, such as household items, etc.)

„

Places with high levels of electromagnetic waves 

such as near an electromagnetic cooker, speakers, 

etc.

The unit may not function correctly.

„

Places exposed to soot (conductive dust) released 

by candles, aromatic candles, etc.

The performance of the fi lters may be impaired, causing 
the room to become dirty due to the build-up of dust that 
is not captured.

„

Do not use cosmetics etc., containing silicone* near 

the unit.

*  Hair care products (split ends coating agents, hair 

mousse, hair treatment agents etc.), cosmetics, 
antiperspirants, antistatic agents, waterproof sprays, 
lustering agents, glass cleaners, chemical wiping 
cloths, wax, etc.

•  Insulators such as silicone may adhere to the needle 

of the streamer unit, and the streamer discharge may 
not be generated.
If that happens, clean the streamer unit. 

Page 32

•  The dust collection fi lter may become clogged up, 

resulting in loss of air purifying capacity.

„

Do not use an ultrasonic humidifi er or similar 

appliance near the unit.

The dust collection fi lter may become clogged up, 
resulting in loss of air purifying capacity.

Keep out of 
direct sunlight

Do not block air 
inlets or air outlet

Do not expose to 
direct airfl ow

Keep TVs and radios 
at least 2m away

Summary of Contents for MCK70YV

Page 1: ...g Air Purifier Model Thank you for purchasing this humidifying air purifier Please read the operation manual carefully and follow it for correct use Please read the Safety Precautions section before u...

Page 2: ...ters Replace 31 Streamer Unit 32 Dust Collection Filter Replace 33 When Not Using the Unit for a Prolonged Period 33 Operation When you want to let the unit decide the best operation mode 15 AUTO oper...

Page 3: ...the power supply plug or cord is damaged it must be replaced by the manufacturer its service agent or a similar qualified person in order to avoid a hazard An electric shock short circuiting or fire m...

Page 4: ...sounds or vibrations during operation The casing of the unit has become deformed or is abnormally hot There is a burnt smell Malfunction an electric shock smoke fire etc may result if the abnormality...

Page 5: ...supply cord Fire an electric shock or injury may result When using the humidifier maintain the cleanliness of the water tank humidifying tray and humidifying filter unit at all times Replace the wate...

Page 6: ...deformation may result On top of a thick carpet bed cover or mattress The unit may tilt causing water to spill or the water level sensor may fail to work correctly Places exposed to direct sunlight D...

Page 7: ...is below Louvre Hand operated Water tank Humidifying filter unit Page 29 30 Humidifying tray Page 29 Air inlets Grip for carrying the unit Pre filter Filter frame Black Page 13 14 27 Streamer unit Ind...

Page 8: ...dust PM2 5 sensor This is normal not a malfunction Dust PM2 5 sensor detection range Detectable matter house dust tobacco smoke pollen mite droppings and remains pet hairs diesel particulate matter S...

Page 9: ...lug is inserted every time Insert the power supply plug when the air is clean odour free Odour sensor detection range Detectable matter tobacco odours cooking odours pet odours toilet smells waste sme...

Page 10: ...e 20 HUM lamp orange Lamp will light up when the humidifying operation is active GOOD SLEEP MODE lamp green Lamp will light up when in GOOD SLEEP MODE Page 20 BRIGHTNESS button During operation each t...

Page 11: ...the power ON or OFF AUTO operation lamp green Lights up during AUTO operation Page 15 HUM button Humidifying operation ON OFF and the humidification mode can be selected Page 17 The lamp turns off whe...

Page 12: ...is not a defect Pointers for good positioning Choose a position from where airflow can reach all areas of the room Place on a stable surface If the unit is placed on an unstable surface vibrations fro...

Page 13: ...ten the cap on the water tank If not done water leakage could result Water can be filled right up to the neck Tighten securely Note that even if tightened securely and completely the screw threads wil...

Page 14: ...ing the tab in the centre remove the hooks 4 places on the left right from the holes in the unit 4 places on the left right Pre filter Holes 4 places left right Hooks Hooks 4 places left right 4 Remov...

Page 15: ...om part fully behind the protrusions Dust collection filter The dust collection filter has a special orientation Check the symbol on the upper part of the filter before attaching Deodorising filter Pr...

Page 16: ...ow Standard High Monitoring mode Blinking About AUTO operation The unit automatically switches between air purifying operation and humidifying operation based on the indoor temperature and humidity co...

Page 17: ...leep hours As the deodorising capacity is reduced it is recommended that the FAN setting be set to Standard or above if odour needs to be quickly eliminated from a room Turbo The ambient air is quickl...

Page 18: ...ng operation exclusively Attention Make sure that the humidifying filter unit is attached when using this operation Change the water in the humidifying tray and water tank everyday Be sure to use tap...

Page 19: ...on in 10m area over 1 hour Assuming 1 cigarette was smoked immediately after the unit was turned on Power saving mode FAN setting switches automatically between Quiet and Low If the air is clean and t...

Page 20: ...ated 100 90 80 70 60 50 40 30 0 30 25 20 15 10 Room conditions and target humidity Target humidity Room temperature C 60 50 40 70 CIRCULATOR When you want to circulate the air in the room The air in t...

Page 21: ...ble for when you are sleeping or taking a nap etc The airflow rate is adjusted automatically between 3 levels Quiet Low and Standard The indicator lamp brightness is set to OFF Streamer discharge stop...

Page 22: ...gh will blink for about 5 seconds and then the lamp corresponding to the current setting will light up Current setting HUM lamp Low HUM lamp High ON OFF Lit up OFF Lit up OFF 3 Press to change the out...

Page 23: ...Current setting FAN lamp Quiet FAN lamp Standard Normal OFF Lit up Low Lit up OFF 3 Press to change the output settings Each press cycles between Normal and Low streamer output The MODE ANTI POLLEN la...

Page 24: ...es between the FAN lamps allowing you to change the sensitivity To set sensitivity High Select the FAN lamp Turbo Turbo Standard Low High Normal Low The sensor is highly receptive The sensor is slight...

Page 25: ...down for about 3 seconds with the power supply plug inserted and the unit turned off Each time is held down for about 3 seconds the setting switches between ON and OFF When the setting is changed to...

Page 26: ...amp will light up or blink depending on the setting status 3 Press to change the setting Each press turns the ECONO MODE lamp ON or OFF The HUM lamp Low will remain lit up To turn Monitoring mode ON T...

Page 27: ...26 Advanced Settings English This page is blank to make the next chapter easier for users to read as well as to satisfy typesetting constraints...

Page 28: ...or holes are opened etc dust will pass through the filter and capacity for dust collection will be reduced Page 33 4 Deodorising Filter 5 Streamer Unit Wear gloves when working Dust from the deodoris...

Page 29: ...n dirt on the exterior of the water tank becomes an issue Wipe Each season or when water scales white and brown are hard to remove Soak in citric acid or lemon juice About every 10 years Replace Wipe...

Page 30: ...Sectional view Float Fill the tray with water and check that the float rises to the water surface After checking be sure to discard the water then attach the humidification tray to the unit Removing...

Page 31: ...at a pharmacy drug store or super market Usage quantity 1 4 cup of lemon juice per 3 cups of water Bottled 100 lemon juice can be used Use only 100 lemon juice with no pulp strain juice if necessary...

Page 32: ...ter Push frame hooks in direction of arrow Do not dispose of the frame Do not dispose of axle About the water scoop If the frame upper half is impacted the water scoop on the back side may detach Humi...

Page 33: ...Grip Streamer unit Hold the centre of the grip and insert slowly and fully 8 Attach the front panel Page 14 1 Remove the power supply plug 2 Remove the front panel Page 13 3 Remove the streamer unit S...

Page 34: ...cket and operate Dust Collection Filter Replace Replace about every 10 years About part replacement timing Replacement timing depends on usage patterns and the location of the unit Standard replacemen...

Page 35: ...dust collection filter easily turns black A The blackening does not affect dust collection performance However it can be replaced if it is an issue Dust collection filter Q No steam is visible during...

Page 36: ...er socket then remove the filter from the bag Finally re attach the filter and start operation again Are the front panel pre filter dust collection filter humidifying filter unit humidifying tray and...

Page 37: ...er unit dirty A sound may be generated when there is a buildup of water scales on the humidifying tray or humidifying filter unit Clean these parts Page 29 30 Splashing sound during Humidifying operat...

Page 38: ...was cleaned Did you clean it after unplugging the power supply plug Unplug the unit wait at least 5 seconds and then reinsert the power supply plug Is the streamer unit securely attached Insert the st...

Page 39: ...oom Is the louvre closed Open the louvre Page 15 Is the pre filter or dust collection filter dirty Clean the pre filter replacement of the dust collection filter may also be necessary Page 27 The air...

Page 40: ...hieved Are you using the unit in a room with an area larger than applicable Page 42 Is the target humidity set to Low or Standard Is the FAN setting set to Quiet or Low Set the humidification mode to...

Page 41: ...rt is not attached unplug the unit and attach all the parts before turning the unit on again There is a burnt mark on the metal part of the streamer unit This is a mark left from the streamer discharg...

Page 42: ...er made of polyester and polypropylene and the humidifying filters made of polyester Disposal requirements Units are marked with the following symbol This means that electrical and electronic products...

Page 43: ...ater tank is empty Water tank volume L About 3 6 Power supply cord length m 2 Made in China These specification values are applicable to both 50Hz 220 240V and 60Hz 220 230V Even when the power is off...

Page 44: ...bar code is a manufacturing code DAIKIN ISITMA VE SO UTMA S STEMLER SAN T C A G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 0...

Reviews: