8 Hand-over to the user
Installation manual
27
LMSEY1A09/13 + LMSEY2A19/25
Daikin LMS
4P728170-1 – 2023.03
WARNING
▪ NEVER
directly
touch
any
accidental
leaking
refrigerant. This could result in severe wounds caused
by frostbite.
▪ Do NOT touch the refrigerant pipes during and
immediately after operation as the refrigerant pipes
may be hot or cold, depending on the condition of the
refrigerant flowing through the refrigerant piping,
compressor, and other refrigerant cycle parts. Your
hands may suffer burns or frostbite if you touch the
refrigerant pipes. To avoid injury, give the pipes time to
return to normal temperature or, if you must touch
them, be sure to wear proper gloves.
NOTICE
At the end of the commissioning procedure, the alarm log
can be reset (if necessary) via the Daikin Installer app.
8
Hand-over to the user
Once the test run is finished and the unit operates properly, make
sure the following is clear for the user:
▪ Make sure that the user has the printed documentation and ask
him/her to keep it for future reference. Inform the user that he can
find the complete documentation at the URL mentioned earlier in
this manual.
▪ Explain the user how to properly operate the system and what to
do in case of problems.
9
Disposal
Wooden, plastic and polystyrene packing must be disposed of
according to the regulations in force in the country where the unit is
used.
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation.
Final disposal of the unit must be done by an authorised
area technical assistance service, that has proper training,
equipment and instructions for the dismantling. They are
also responsible for reuse, recycling and recovery.
CAUTION
There are potential environmental hazards involved in
dismantling the unit.
10
Technical data
▪ A
subset
of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The
full set
of latest technical data is available on the Daikin
Business Portal (authentication required).
10.1
Wiring diagram
▪ A printed version of the declaration of conformity, the wiring- and
piping diagrams is included with the unit.
Wiring diagram legend
For applied parts and numbering, refer to the wiring diagram on the
unit. Part numbering is by Arabic numbers in ascending order for
each part and is represented in the overview below by "*" in the part
code.
Symbol
Meaning
Symbol Meaning
Circuit breaker
contact
Noise filter
3
MS
Compressor
Power supply plug
Connection
p
Pressure switch
Connector
Protective earth
Contactor contact
Relay
M
Expansion valve
Relay contact
MS
Fan
Resistor
Fuse
Solenoid valve
M
Fuel pump
Speed sensor
M
3
Generator
t°
Temperature sensor
Heater
Terminal
Inverter reactor
Terminal strip
Main switch
Transformer
LM13AVM01
Symbol
Meaning
ACU
Unit controller
CF1
Condensor fan
C1
Compressor
C1 (cable)
Supply cable
C2 (cable)
Door heater cable
C3 (cable)
Room light cable
C4 (cable)
Door switch cable
C5 (cable)
Inverter supply cable
C6 (cable)
PWM inverter 1 cable
EDH
Evaporator drain heater
EF1
Evaporator fan
EVM
Electronic expansion valve
F1
Main line fuse
F2
Main neutral fuse
F3
Line aux fuse
F4
Neutral aux fuse
HMI
User interface
HMI cable
User interface cable connection
HPS
High pressure switch
INV
Inverter compressor