background image

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

MODELS

FTXS85LVMA
FTXS95LVMA

00_CV_3P291209-3.indd   1

00_CV_3P291209-3.indd   1

11/30/2011   2:37:19 PM

11/30/2011   2:37:19 PM

Summary of Contents for Inverter FTXS85LVMA

Page 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXS85LVMA FTXS95LVMA 00_CV_3P291209 3 indd 1 00_CV_3P291209 3 indd 1 11 30 2011 2 37 19 PM 11 30 2011 2 37 19 PM...

Page 2: ...the outdoor unit This function is useful when you need to consider the noise for your neighbourhood Page 18 INTELLIGENT EYE The INTELLIGENT EYE sensor detects the human movement in a room If no one i...

Page 3: ...ration 18 ECONO Operation 19 OFF TIMER Operation 20 ON TIMER Operation 21 WEEKLY TIMER Operation 22 Multi Connectio n Note for Multi System 28 Car e Care and Cleaning 30 Troubleshootin g Troubleshooti...

Page 4: ...ner or otherwise fire may result Beware of fire in case of refrigerant leakage If the air conditioner is not operating correctly i e not generating cool or warm air refrigerant leakage could be the ca...

Page 5: ...nly connect the air conditioner to the specified power supply circuit Power supplies other than the one specified may result in electric shocks overheating and fires Arrange the drain hose to ensure s...

Page 6: ...TIMER lamp yellow Page 20 21 INTELLIGENT EYE lamp green Page 15 16 Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a beep sound Case Sound...

Page 7: ...r filter Titanium apatite photocatalytic air purifying filter Refrigerant piping and inter unit wiring Earth terminal It is inside of this cover Model name plate Drain hose Air inlet Back and side Air...

Page 8: ...AN setting button It selects the airflow rate setting Page 14 POWERFUL button POWERFUL operation Page 17 Display LCD It displays the current settings In this illustration each section is shown with al...

Page 9: ...OFF TIMER and WEEKLY TIMER settings Page 20 21 22 QUIET button OUTDOOR UNIT QUIET operation Page 18 COMFORT SENSOR button COMFORT AIRFLOW and INTELLIGENT EYE operation Page 15 16 OFF TIMER button Pag...

Page 10: ...the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both 2 batteries with new size AAA LR03 alkaline The attached batteries...

Page 11: ...d closes once to set the reference position To set the clock Press 1 is displayed and blink Press 2 to set the current day of the week Press 3 blinks Press 4 to set the clock to the present time Holdi...

Page 12: ...of heating operation it takes some time before the room gets warmer In HEAT operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosti...

Page 13: ...umes a small amount of electricity even while it is not operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off Use the air con...

Page 14: ...g The 3 D airflow direction Press and and are displayed on the LCD The flaps and louvers move in turn To cancel 3 D airflow press either or again The flaps or louvers will stop moving To set the flaps...

Page 15: ...ion Upper limit Lower limit COMFORT AIRFLOW Upper limit Lower limit Stop operation 10 15 50 30 70 75 15 70 Note on 3 D airflow Using 3 D airflow circulates cold air which tends to collected at the bot...

Page 16: ...tion The set temperature is shifted in 2 C steps Someone is back in the room Back to normal operation The air conditioner will return to normal operation when the sensor detects the movement of people...

Page 17: ...on INTELLIGENT EYE operation Application range is as follows 90 55 7m 55 Vertical angle 90 Side view Horizontal angle 110 Top view 7m Sensor may not detect moving objects further than 7m away Check t...

Page 18: ...ther with ECONO COMFORT AIRFLOW or OUTDOOR UNIT QUIET operation Priority is given to the function of whichever button is pressed last POWERFUL operation can only be set when the unit is running Pressi...

Page 19: ...UTDOOR UNIT QUIET operation will work only when this function is set on all operated indoor units However if using priority room setting refer to Note for multi system Page 28 This function is availab...

Page 20: ...Maximum during normal operation Maximum during ECONO operation Normal operation ECONO operation From start up until set temperature is reached Running current and power consumption This diagram is a...

Page 21: ...The TIMER lamp lights yellow Display To cancel OFF TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off NOTE Notes on TIME...

Page 22: ...me are displayed on the LCD The TIMER lamp lights yellow Display To cancel ON TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp...

Page 23: ...age 25 6 00 8 30 17 30 22 00 25 C 27 C Program 1 Program 2 Program 3 Program 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings up to programs 1 4 Page 23 8 00 10 00 19 00 21 00 27...

Page 24: ...be displayed 1 to 4 settings can be made per day Press 2 to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week Press 3 The day o...

Page 25: ...ot be used to go back to the reservation number 6 Press to select the desired time The time can be set between 0 00 and 23 50 in 10 minute intervals To return to the ON OFF TIMER mode setting press Go...

Page 26: ...ill be copied Press 4 to select the destination day of the week Press 5 The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week will be cop...

Page 27: ...on number and press The mode is switched to setting mode Go to Setting mode STEP 4 Page 23 Press 3 to exit confirming mode is displayed on the LCD and WEEKLY TIMER operation is activated The TIMER lam...

Page 28: ...TIMER operation will be activated The reservations for each day of the week This function can be used for deleting reservations for each day of the week It can be used while confirming or setting rese...

Page 29: ...rity room setting on the next page NIGHT QUIET operation Available only for COOL operation NIGHT QUIET operation requires initial programming during installation Please consult your retailer or dealer...

Page 30: ...om B C and D Status of room B C and D when the unit in room A is in COOL operation COOL or DRY or FAN Current operation mode maintained HEAT The unit enters standby mode Operation resumes when the roo...

Page 31: ...ion and turn the breaker off Do not touch the aluminum fins of the indoor unit If you touch those parts this may cause an injury Air filter Vacuum dust or wash the filter Once every 2 weeks Refer to P...

Page 32: ...side 1 Slide 2 Pull Front panel shaft 1 Slide 2 Pull Disconnect the front panel shaft on the other side in the same manner Clean the front panel 2 Wipe it with a soft cloth soaked in water Only neutr...

Page 33: ...o clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with lukewarm water then dry them up in the shade Be sure to remove the t...

Page 34: ...and replace with a new filter Do not throw away the filter frame Reuse the filter frame when replacing the titanium apatite photocatalytic air purifying filter Dispose of the old filter as non flammab...

Page 35: ...ion stops turn off the breaker for the room air 2 conditioner Clean the air filters and set them again 3 Take out batteries from the remote controller 4 When a multi outdoor unit is connected make sur...

Page 36: ...nd is generated when refrigerant flows during defrosting operation Clicking sound during operation or idle time This sound is generated when the refrigerant control valves or the electrical parts oper...

Page 37: ...p flashes Are the air filters clean Clean the air filters Is there anything to block the air inlet or the outlet of the indoor and the outdoor units Turn the bleaker off and take all obstacles away Th...

Page 38: ...The ON OFF TIMER does not operate according to the settings Check if the ON OFF TIMER and the WEEKLY TIMER are set to the same time Change or deactivate the settings in the WEEKLY TIMER Page 22 The in...

Page 39: ...normal sound is heard during operation The safety breaker a fuse or the earth leakage breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning sme...

Page 40: ...FAULTY SUCTION AIR TEMPERATURE SENSOR J3 FAULTY DISCHARGE PIPE TEMPERATURE SENSOR J6 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR L3 ELECTRICAL PARTS HEAT FAULT L4 HIGH TEMPERATURE AT INVERTER CIRCUIT HEA...

Page 41: ...40 MEMO 01_EN_3P291209 3 indd 40 01_EN_3P291209 3 indd 40 12 8 2011 8 52 23 PM 12 8 2011 8 52 23 PM...

Page 42: ...41 MEMO 01_EN_3P291209 3 indd 41 01_EN_3P291209 3 indd 41 12 8 2011 8 52 23 PM 12 8 2011 8 52 23 PM...

Page 43: ...42 MEMO 01_EN_3P291209 3 indd 42 01_EN_3P291209 3 indd 42 12 8 2011 8 52 23 PM 12 8 2011 8 52 23 PM...

Page 44: ...3P291209 3 M11B023 1112 HT Two dimensional bar code is a code for manufacturing Quick Reference 00_CV_3P291209 3 indd 2 00_CV_3P291209 3 indd 2 11 30 2011 2 37 25 PM 11 30 2011 2 37 25 PM...