DAIKIN ROOM AIR CONDITIONER

FTKD50BSG

FTKD60BSG

FTKD71BSG

Operation Manual

MODELS

Summary of Contents for Inverter FTKD50BSG

Page 1: ...DAIKIN ROOM AIR CONDITIONER FTKD50BSG FTKD60BSG FTKD71BSG Operation Manual MODELS ...

Page 2: ...cal blade louvre 11 3 D air flow 11 POWERFUL Operation 12 OUTDOOR UNIT SILENT Operation 12 HOME LEAVE Operation 13 Timer Operation OFF TIMER operation 15 ON TIMER operation 15 CARE Care and Cleaning Cleaning the air filters 16 Cleaning the indoor and outdoor units and the remote controller 16 Replacing photo catalytic deodorizing air cleaning filter 16 Cleaning the front grille 17 Check 17 Before ...

Page 3: ... a qualified repairman before attempting any repairs which might accompany addition of refrigerant The refrigerant used in the air conditioner is safe Although leaks should not occur if for some reason any refrigerant happens to leak into the room make sure it does not come in contact with any flame such as fan heaters kerosene heaters or gas ranges as this may result noxious substances being gene...

Page 4: ...WARNING CAUTION Installation Do not stand or sit on the outdoor unit Do not place any object on the unit The object or the person may fall down or drop causing injury Do not place under the indoor or outdoor unit anything which must be kept away from moisture Indoor unit moisture in the air may condense and drip in certain conditions outdoor unit during cooling operation condensation may drip from...

Page 5: ...door unit or the operation noise will not annoy your neighbours Consider nuisance to your neighbours from noises Electrical work Relocating the air conditioner requires specialized knowledge and skills Please consult the shop where you bought the air conditioner if relocation is necessary for moving or remodeling System relocation Note for Multi System Priority room setting When setting the priori...

Page 6: ...ay rotate inside and may cause injury CAUTION Receiver FTKD COOL Mode 22 C Temperature setting AUTO Air flow rate DAIKIN Front grille Indicator lamps Grille tab Diffuser OPERATION lamp green HOME LEAVE lamp red TIMER lamp yellow The louvre is inside of the air outlet See page 11 Lights up when you use HOME LEAVE Operation See page 13 Air outlet Louvre vertical blades See page 11 See page 15 Flap H...

Page 7: ...mer setting FAN setting button It selects the air flow rate setting SWING buttons See page 11 It changes the temperature or time setting Display It displays the current settings In this illustration each section is shown with all its displays ON for the purpose of explanation POWERFUL button See page 12 See page 15 It selects the operation mode DRY COOL FAN See page 10 HOME LEAVE button See page 1...

Page 8: ...n hose Appearance of the outdoor unit may differ with some models Refrigerant piping and inter unit cable Air outlet Air inlet Earth terminal It is inside of this part Drain hose Air inlet Air outlet Back and side Refrigerant piping and inter unit cable Earth terminal It is inside of this part Drain hose Appearance of the outdoor unit may differ with some models RKD ...

Page 9: ...not drop the remote controller Do not get it wet The maximum distance for communication is about 7 m To remove pull it upwards ATTENTION Remote controller holder Set Push 1 2 To fix the remote controller holder on the wall Choose a place from where the signals reach the unit Fix the holder to a wall a pillar etc with the screws supplied with the holder Fit the claw of the holder into the bottom of...

Page 10: ...h an photo catalytic deodorizing air cleaning filter to each air filter See page 16 Care and cleaning Set the air filters in their original positions and close the front grille Operation without air filters may result in troubles as dust will accumulate inside the indoor unit 3 4 1 is displayed 2 blinks 3 Please note The air conditioner always consumes 15 35 watts of electricity even while it is n...

Page 11: ...hange the temperature setting To change the air flow direction See page 11 At smaller air flow rates the cooling effect is also smaller DRY COOL FAN Operation 1 2 Display COOL mode Press to raise the temperature and press to lower the temperature Set to the temperature you like DRY or FAN mode The temperature setting is not variable To change the air flow rate setting COOL or FAN mode Five levels ...

Page 12: ...nism may be broken Notes on flap angles Adjusting the vertical blade louvre Press Every time the button is pressed appears or disappears The louvre automatically swings right and left To stop the flap at an angle you like press DRY COOL NOTE Unless SWING is selected you should set the flap at a nearhorizontal angle in COOL or DRY mode to obtain the best performance 3 D air flow The 3 D air flow fu...

Page 13: ...s lowered by 3 C and the air flow rate is slightly increased In FAN mode The air flow rate is fixed to the maximum set ting OUTDOOR UNIT SILENT operation lowers the noise level of the outdoor unit by changing the frequency and fan rpm on the outdoor unit This function is convenient when sleeping etc How to use OUTDOOR UNIT SILENT operation To use the OUTDOOR UNIT SILENT operation Press To cancel t...

Page 14: ...to set the temperature and air flow rate Press Adjust the set temperature with as you like 1 2 3 Adjust the air flow rate setting with FAN as you like The temperature and air flow rate will be the same as the previous settings starting with the second use If you want to change the settings from the previous use repeat steps 1 through 3 What s the HOME LEAVE operation What is HOME LEAVE operation U...

Page 15: ...ration will continue when the unit is turned back on 1 Every day before you leave the house 2 Before bed When you go out push the HOME LEAVE operation button and the air conditioner will adjust capacity to reach the preset temperature for HOME LEAVE operation When you return you will be welcomed by a comfortably air conditioned room Push the HOME LEAVE operation button again and the air conditione...

Page 16: ...nditioner is not operating Press ON TIMER once again Check that the clock is correct If not set the clock to the present time See page 9 1 blinks 2 Press until the time setting reaches the point you like Every pressing of either button increases or decreases the time setting by ten minutes Holding down either button changes the setting rapidly 3 Combining ON TIMER and OFF TIMER ATTENTION In the fo...

Page 17: ...other hard stuff Attach the photo catalytic deodorizing air cleaning filter Care and Cleaning CAUTION NOTE Insert claws of the filters into slots of the front panel The front grille should lock at both sides and at the point in the middle Push the grille at the 4 points indicated by In a dusty environment clean the air filters at least once in every two weeks Operation with dusty air filters lower...

Page 18: ...eys of the front grille into the slots and push them in all the way Supporting the front grille with one hand fit the lock by sliding up the lever with the other hand Close the front grille slowly in this state Push the grille at the 3 points two at both sides and in the middle Open the front grille Hold the grille by the tabs on the two sides and lift it until it stops with a click Before a long ...

Page 19: ...o water on the cool surface of outdoor unit piping and drips This happens when the air in the room is cooled into mist by the cold air flow during cooling operation This happens when smells of the room furniture or cigarettes are absorbed into the unit and discharged with the air flow If this happens we recommend you to have the indoor unit washed by a technician Consult the service shop where you...

Page 20: ...on set appropriately Are the air filters clean Is there anything to block the air inlet or the outlet of the indoor and the outdoor units Clean the air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still blinks call the service shop where you bought the air conditioner Are operation mod...

Page 21: ...e or the earth leakage breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn the breaker OFF and call the service shop We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor performance It is ...

Page 22: ...3P111151 4 M02B248 0303 HT ...