background image

 

FXMQ-MA

E E D E N 1 1 - 2 0 4

Air Conditioners

Large concealed ceiling unit

Technical Data

Summary of Contents for FXMQ-MA

Page 1: ...FXMQ MA E E D E N 1 1 2 0 4 Air Conditioners Large concealed ceiling unit Technical Data...

Page 2: ...FXMQ MA E E D E N 1 1 2 0 4 Air Conditioners Large concealed ceiling unit Technical Data...

Page 3: ...ems 6 Control Systems 6 5 Capacity tables 7 Cooling Capacity Tables 7 Heating Capacity Tables 8 6 Dimensional drawings 9 Dimensional Drawings 9 7 Centre of gravity 10 Centre of Gravity 10 8 Piping dia...

Page 4: ...s Unit Height mm 470 Width mm 1 380 Depth mm 1 100 Weight Unit kg 137 Heat exchanger Rows Quantity 3 Fin pitch mm 2 0 Face area m 0 68 Stages Quantity 26 Fan Type Sirocco fan Quantity 2 Air flow rate...

Page 5: ...t its colorimetric method gravity method 50 or more 6 Sound pressure levels are measured at 220V 7 Voltage range units are suitable for use on electrical systems where voltage supplied to unit termina...

Page 6: ...ge concealed ceiling unit FXMQ MA VRV Systems Indoor Unit 4 2 Safety device settings 2 1 Safety Device Settings 04 0 6DIHW GHYLFHV 04a0 3 ERDUG IXVH 9 9 DQ PRWRU WKHUPDO IXVH DQ PRWRU WKHUPDO SURWHFWR...

Page 7: ...I A R D 0 8 2 L 2 7 3 J F A K 5 6 R E T L I F Y C N E I C I F F E H G I H 0 8 2 L 3 7 3 J F A K 0 9 R E T L I F Y C N E I C I F F E H G I H 0 8 2 L 5 0 7 3 J D K R E B M A H C R E T L I F 0 8 2 L 1 7...

Page 8: ...5HPRWH FRQWURO IRU KRWHO XVH 5 GDSWHU IRU ZLULQJ 53 LULQJ DGDSWHU IRU HOHFWULFDO DSSHQGLFHV 53 LULQJ DGDSWHU IRU HOHFWULFDO DSSHQGLFHV 53 5HPRWH VHQVRU 5 6 QVWDOODWLRQ ER IRU DGDSWHU 3 HQWUDO UHPRWH...

Page 9: ...0 15 1 13 4 18 0 14 9 21 0 16 3 22 4 16 8 23 8 17 0 24 5 16 3 25 0 15 6 35 0 15 1 13 4 18 0 14 9 21 0 16 3 22 4 16 8 23 6 17 0 24 2 16 1 24 6 15 4 37 0 15 1 13 4 18 0 14 9 21 0 16 3 22 4 16 8 23 2 16...

Page 10: ...0 4 1 25 4 25 4 25 0 24 2 23 4 21 8 7 0 6 0 26 2 26 2 25 0 24 2 23 4 21 8 9 0 7 9 27 1 26 6 25 0 24 2 23 4 21 8 11 0 9 8 27 9 26 6 25 0 24 2 23 4 21 8 13 0 11 8 28 2 26 6 25 0 24 2 23 4 21 8 15 0 13...

Page 11: ...piping 9 5 FXMQ250MA 22 2 attached piping 9 5 NOTES 1 Location of unit s name plate switch box surface 2 Mount the air filter at the suction side Select its colorimethod gravity method 50 or more Nr P...

Page 12: ...Indoor Unit Large concealed ceiling unit FXMQ MA VRV Systems Indoor Unit 10 7 Centre of gravity 7 1 Centre of Gravity FXMQ200 250MA 4D035171 Air outlet Air inlet...

Page 13: ...nit FXMQ MA 8 Piping diagrams 8 1 Piping Diagrams FXMQ MA 4D034245 Heat exchanger Fan Filter Filter Electronic expansion valve Liquid pipe connection port Gas pipe connection port Piping connection di...

Page 14: ...UHOD 0 3 0 3 0RWRU GUDLQ SXPS 31 SLQN 7 ZKLWH 0 0 0RWRU LQGRRU IDQ HOORZ 25 RUDQJH 4 0 4 0 7KHUPR VZLWFK 0 HPEHGGHG 8 EOXH EODFN 5 7 7KHUPLVWRU DLU 5 UHG 51 EURZQ 127 6 WHUPLQDO EORFN FRQQHFWRU WHUPL...

Page 15: ...S 1 Reference acoustic pressure 0 dB 20 Pa 2 Measuring place anechoic chamber 3 Operation noise differs with operation and ambient conditions Data were not available at the time of publication Model S...

Page 16: ...ectrum FXMQ200MA 4D035168 Approximate threshold hearing for continuous noise Octave band center frequency Hz Octave band sound pressure level dB OdB 0 0002 bar FXMQ250MA 4D035169 Approximate threshold...

Page 17: ...of ESP standard ESP Lower limit of ESP high ESP High standard ESP Low standard ESP Lower limit of ESP standard ESP mmH20 Pa mmH20 Air flow m3 min External static pressure NOTES 1 The remote control ca...

Page 18: ...nstall a canvas duct to the air discharge outlet and air inlet so that vibration from the machine body is not transmitted to the duct or ceiling You should also apply acoustic insulation material to t...

Page 19: ...tems Indoor Unit 17 Indoor Unit Large concealed ceiling unit FXMQ MA 12 Installation 12 2 Service Space A M 0 5 2 0 0 2 Q M X F 3P086156 2 4 service space Min 650 470 NOTE 1 Above figures mean minimum...

Page 20: ...on the environment This challenge demands the eco design and development of a wide range of products and an energy management system resulting in energy conservation and a reduction of waste Daikin pr...