Specifications

General Data

NOTES:

1)  ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2)  ALL THE UNITS ARE BEING TESTED UNDER FOLLOWING CONTITION:

 

• COOLING-27°C DB/19.5°C WB INDOOR AND WATER INLET 7°C OUTLET 12°C

 

• HEATING-21°C DB INDOOR AND WATER 60°C INLET.WATER FLOW:SAME WITH COOLING CONDITION.

3)  SOUND PRESSURE LEVEL ARE ACCORDING TO MICROPHONE POSITION OF THE MEASUREMENT POINT  

IS 1m IN FRONT END

FWW-VC

MODEL

FWW200VC FWW300VC FWW400VC FWW500VC FWW600VC FWW700VC FWW800VC FWW1000VCFWW1200VCFWW1400VC

Air 

Flow

HIGH

m

3

/h

340

510

680

850

1020

1170

1360

1700

2040

2380

CFM

200 

300 

400 

500 

600 

688 

800 

1000 

1200 

1400 

MEDIUM

m

3

/h

279

418

558

697

836

959

1115

1394

1673

1952

CFM

164 

246 

328 

410 

492 

564

656 

820 

984 

1148 

LOW

m

3

/h

170

255

340

425

510

585

680

850

1020

1190

CFM

100 

150 

200 

250 

300 

344 

400 

500 

600 

700 

EXTERNAL  

STATIC PRESSURE

Pa/in.wg 

12,30,50/0.05,0.12,0.20

TOTAL COOLING 

CAPACITY

W

2220 

3300 

4260 

5050 

5820 

6600 

8200 

9300 

11190 

13000 

Btu/h

7575 

11260 

14536 

17231 

19859 

22520 

27980 

31733 

38182 

44358 

SENSIBLE 

COOLING 

CAPACITY

W

1380 

2220 

2770 

3400 

4000 

4550 

5500 

6500 

7700 

9200 

Btu/h

4709 

7575 

9452 

11601 

13649 

15525 

18767 

22179 

26273 

31392 

TOTAL HEATING 

CAPACITY

W

3500 

5330 

6800 

8400 

9600 

11100 

13500 

15800 

18300 

21500 

Btu/h

11942 

18187 

23203 

28662 

32757 

37875 

46064 

53912 

62442 

73361 

WATER FLOW 

RATE

m

3

/h

0.37

0.58

0.72

0.88

1.02

1.14

1.41

1.67

1.95

2.29

USGPM

1.6 

2.6 

3.2 

3.9 

4.5 

5.0 

6.2 

7.4 

8.6 

10.1 

HEAD LOSS 

(Cooling)

Pa

25

21

30

30

32

35

32

40

35

50

in.wg.

0.1 

0.1 

0.1 

0.1 

0.1 

0.1 

0.1 

0.2 

0.2 

0.2 

UNIT WEIGHT

(Without plenum)

kg

10.3

12.4

12.8

15.1

16.7

17.6

25.2

28.6

31.0

33.5

lb

22.7

27.3 

28.2 

33.3 

36.8 

38.8 

55.6 

63.1 

68.3 

73.9

UNIT GROSS 

WEIGHT

(Without plenum)

kg

12.4

14.7

15.3

17.8

19.4

20.4

28.9

32.4

35.4

38.5

lb

27.3 

32.4 

33.7 

39.2 

42.8 

45.0 

63.7 

71.4 

78.0 

84.9 

DIMENSIONS

Without 

Return  

Air Plenum

mm

625×465×235 815×465×235 865×465×235 945×465×235 1045×465×235 1095×465×235 1425×465×235 1475×465×235 1675×465×235 1825×465×235

With Back 

Return  

Air Plenum

mm

625×516×235 815×516×235 865×516×235 945×516×235 1045×516×235 1095×516×235 1425×516×235 1475×516×235 1675×516×235 1825×516×235

With Bottom 

Return  

Air Plenum

mm

625×497×235 815×497×235 865×497×235 945×497×235 1045×497×235 1095×497×235 1425×497×235 1475×497×235 1675×497×235 1825×497×235

UNIT WEIGHT

(With plenum)

kg

13.2

16.0

16.7

19.3

21.2

22.4

31.3

34.8

38.0

41.5

lb

29.1 

35.3 

36.8 

42.5 

46.7 

49.4 

69.0 

76.7 

83.8 

91.5 

UNIT GROSS 

WEIGHT

(With plenum)

kg

15.3

18.3

19.2

22.0

23.9

25.2

35.0

38.6

42.4

46.5

lb

33.7 

40.3 

42.3 

48.5 

52.7 

55.6 

77.2 

85.1 

93.5 

102.5 

CONDENSATE 

DRAIN SIZE

R3/4

Summary of Contents for FWW200VC

Page 1: ...Ceiling Concealed Chilled Water Fan Coil Unit Engineer Data ED FWW VC 201607 Models FWW200VC FWW300VC FWW400VC FWW500VC FWW600VC FWW700VC FWW800VC FWW1000VC FWW1200VC FWW1400VC Air Flow 340 2380m3 h...

Page 2: ...them Warning Moving machinery and electrical power hazard May cause severe personal injury or death Disconnect and lock off power before servicing equipment Literature No ED FWW V 201501 Supersedes E...

Page 3: ...C without return air plenum E back return air plenum 5mm PE insulation F bottom return air plenum 5mm PE insulation Pipe Connection R facing air flow right hand L facing air flow left hand External S...

Page 4: ...ay Valve Kit 3V 3 Way Valve Kit Union Size Omitted R3 4 4 R1 Pipe Connection R for Right hand unit L for Left hand unit E Export U Stick Made In China Power Supply A 220 240V 1Ph 50Hz K 208 230V 1Ph 6...

Page 5: ...for the heat exchanger to endure high pressures and prevent leakage High Efficiency Heat exchanger with the high quality mechanically expanded copper pipe and hydrophilic aluminum fins to ensure high...

Page 6: ...NG CAPACITY W 3500 5330 6800 8400 9600 11100 13500 15800 18300 21500 Btu h 11942 18187 23203 28662 32757 37875 46064 53912 62442 73361 WATER FLOW RATE m3 h 0 37 0 58 0 72 0 88 1 02 1 14 1 41 1 67 1 95...

Page 7: ...908 1238 1288 1488 1638 in 17 24 24 72 26 69 29 83 33 77 35 74 48 73 50 70 58 57 64 47 WIDTH mm 196 in 7 71 THICKNESS mm 8 in 0 31 NOTES 1 ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTUR...

Page 8: ...a Air Flow m 3 h Air Flow m 3 h Air Flow m 3 h ESP Pa ESP Pa FWW1200 FWW1000 FWW800 FWW700 FWW600 FWW500 FWW400 FWW200 FWW300 FWW1200 FWW1000 FWW800 FWW700 FWW600 FWW500 FWW400 FWW200 FWW300 FWW1200 F...

Page 9: ...perating Limits Operating Limits FWW V Water Circuit Max Water side pressure 1 6MPa Min Entering water temperature 3 C cooling Power supply Operating voltage limits 10 Volt Operating frequency limits...

Page 10: ...6 0 7 0 8 0 9 1 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 2 1 2 2 2 3 WATER PRESSURE DROP kPa WATER FLOW m3 h WATER PRESSURE DROP CURVE 3 Rows Water Flow Rate Pressure Drop Chart FWW VC FWW700VC FWW500VC...

Page 11: ...Fans MCW200V WITH BACK PLENUM TERMINAL BOX MOUNTING HOLE 4 10 16 CONDENSATE DRAIN R3 4 AIR VENT WATER SUPPLY CONNECTION Rc3 4 WATER RETURN CONNECTION Rc3 4 Model Standard Drain Pan Long Drain Pan Num...

Page 12: ...INSULATION GRADE B POWER SOURCE V Ph Hz 220 1 50 RATED INPUT POWER W 39 53 72 83 107 122 142 174 217 250 RATED RUNNING CURRENT A 0 18 0 24 0 33 0 38 0 49 0 56 0 65 0 80 1 00 1 19 POLES 4P 50Pa MOTOR...

Page 13: ...HF MF N 220V 50Hz YELLOW BROWN ORANGE YELLOW BROWN ORANGE BLUE BLACK BLACK BLACK BLACK BLUE MOTOR CAPACITOR MOTOR CAPACITOR FAN MOTOR 1 FAN MOTOR 2 Only unit 800 1200 have fan motor2 NOTE HF FAN SPEED...

Page 14: ...ing to the carrier with a formal claim Location Before installation please check the following There must be enough space for unit installation and maintenance Please refer to the unit s drawings and...

Page 15: ...tion Using suitable fittings as water pipe connections Refer to the specification The water inlet is on the bottom while outlet on top The connection must be concealed with rubberized fabric to avoid...

Page 16: ...djusting the water flow and for closing the water circuit when perform maintenance to the unit Y strainer protects unit from impurity increases the service life and insolating valves All parts of 2 wa...

Page 17: ...re 4 For right pipe connection unit Detail is as same as 2 way valve unit The valve kit has been pre assembled for easy installation Where needed the connections are pre coated with sealing material T...

Page 18: ...20 Rc3 4 3 way Valve 3 4 0 18 MC FCV2334G 20 Rc3 4 2 way Valve 3 0 0 18 Pipe Connection 1 Using suitable fittings as water pipe connections with reference to the outline and dimensions 2 The water inl...

Page 19: ...ctrical shock fire or explosion Read the User s Manual carefully before using this product The User s Manual provides important safety instructions and warnings Be sure to follow these instructions an...

Reviews: