Technical manual

FWP CT/CF

EN

2

4

Brushless

2 pipes systems 4 pipes systems Centrifugal fan

Ducted

FEATURES

» 

Permanent magnet EC motor

» 

Low electricity consumption

» 

Easy setup of ventilation section

» 

Heat exchanger up to 4 rows

» 

Compact dimensions

» 

Reversible water connections

» 

Wide range of available accessories

2-8 kW

medium static pressure ducted fan coil units with ec motors

UT66002766-02

04/21

Summary of Contents for FWP CT

Page 1: ...d FEATURES Permanent magnet EC motor Low electricity consumption Easy setup of ventilation section Heat exchanger up to 4 rows Compact dimensions Reversible water connections Wide range of available a...

Page 2: ......

Page 3: ...URE p 4 ELECTRIC MOTOR p 4 AIR FILTER p 4 2 1 AIR INTAKE p 4 HEAT EXCHANGER p 4 FANS p 4 3 INSTALLATION p 5 3 1 INSTALLATION REQUIREMENTS p 5 3 2 ASSEMBLY OF UNITS p 6 4 AVAILABLE ACCESSORIES p 7 5 RA...

Page 4: ...main condensate drip tray is situated inside the structure of the unit and is at a positive pressure relative to the drain outlet to facilitate condensate drainage HEAT EXCHANGER High efficiency stan...

Page 5: ...may be easily set and which is suitable for taking temperature readings where applicable Avoid positions directly exposed to sunlight or direct cur rents of hot or cold air and make sure there are no...

Page 6: ...F UNITS Mounting the unit Insert the vibration dampers provided in the 4 slots indicated for ceiling installation Fasten the base unit to the ceiling or wall using at least 4 of the 8 slots provided I...

Page 7: ...tion kit relay box and safety devices Accessories EPIMSB6 Power interface for connecting in parallel up to 4 fan coil units to the one controller EDPD Auxiliary water drip tray Valves 2 way valves ON...

Page 8: ...60 8 50 3 40 7 60 8 50 6 80 7 50 8 30 6 80 7 50 8 30 Rated air flow E m h 333 687 760 333 687 760 1050 1163 1289 1050 1163 1289 Available static pressure E Pa 12 50 61 12 50 61 40 50 60 40 50 60 Power...

Page 9: ...tage E V 3 40 7 60 8 50 3 40 7 60 8 50 6 80 7 50 8 30 6 80 7 50 8 30 Rated air flow E m h 333 683 755 333 683 755 1050 1163 1289 1050 1163 1289 Available static pressure E Pa 12 50 61 12 50 61 40 50 6...

Page 10: ...3 55 57 0 57 6 51 7 50 4 44 6 37 2 27 1 10 max 36 42 6 42 0 32 8 23 6 17 1 17 4 21 5 35 38 7 38 6 35 2 25 0 16 9 12 6 15 8 med 53 54 0 52 1 52 4 48 1 42 4 32 0 24 0 52 54 7 54 5 49 6 47 1 40 8 32 5 2...

Page 11: ...29 0 21 0 49 51 7 51 5 46 6 44 1 37 8 29 5 19 9 min 56 57 5 54 7 54 6 51 5 46 6 37 2 27 3 55 57 0 57 6 51 7 50 4 44 6 37 2 27 1 10 max 36 42 6 42 0 32 8 23 6 17 1 17 4 21 5 35 38 7 38 6 35 2 25 0 16 9...

Page 12: ...e 2 Water connections additional heat exchanger 1 2 female 3 Condensate discharge diameter 17 FWP C 04 05 06 08 A mm 758 758 968 968 C mm 677 677 887 887 D mm 648 648 858 858 E mm 707 707 917 917 300...

Page 13: ...4 female 2 Water connections additional heat exchanger 1 2 female 3 Condensate discharge diameter 17 300 300 140 100 3 2 2 1 21 227 33 15 D 15 C 685 745 120 26 155 26 E A 385 503 596 618 43 113 220 21...

Page 14: ...e units During installation strictly abide by the indications on the wir ing diagram for the unit control panel combination NOTE The electric wires power and control circuits must be pulled in through...

Page 15: ...T66002766 02 All copying even partial of this manual is strictly forbidden 15 10 ELECTRICAL WIRES FWEC3A wiring diagram with built in inverter motor FWEC3A wiring diagram with separated inverter motor...

Page 16: ...ack GND inverter BU Blue inverter neutral motor VC Cooling mode solenoid valve VH Heating mode solenoid valve DO1 Digital outlet 1 DO2 Digital outlet 2 102 Outlet 0 10V 2 101 Outlet 0 10V 1 COM Common...

Page 17: ...bymeansofthespecificinterfacewithparameter description FWTSKA water temperature sensor for microprocessor controls model FWECS FWEC3A Directly connected to the microprocessor controllers FWECSandFWEC3...

Page 18: ...are available for FWP C units installed horizontally EH additional electric heating element Useful as heating integration to the hot water system the EH kit is made of an electric heater with safety...

Page 19: ...rom the power supply by setting the main switch on 0 OFF To clean the air filter proceed as follows 1 Access the unit via the inspection panel and take out the air filter as shown in Air filter 2 If t...

Page 20: ...FWP C Technical manual 20 Standard air intake...

Page 21: ...UT66002766 02 All copying even partial of this manual is strictly forbidden 21...

Page 22: ...FWP C Technical manual 22...

Page 23: ...UT66002766 02 All copying even partial of this manual is strictly forbidden 23...

Page 24: ...Zandvoordestraat 300 B 8400 Oostende Belgium...