background image

MODELS
FVXS25GV1A

FVXS50GV1A

FVXS35GV1A

DAIKIN ROOM AIR CONDITIONER

Operation Manual

00_CV_3P232453-1.fm  Page 1  Wednesday, June 4, 2008  3:09 PM

Summary of Contents for FVXS25GV1A

Page 1: ...MODELS FVXS25GV1A FVXS50GV1A FVXS35GV1A DAIKIN ROOM AIR CONDITIONER Operation Manual...

Page 2: ...ation 7 OPERATION AUTO DRY COOL HEAT FAN Operation 10 Adjusting the Airflow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT QUIET Operation 15 ECONO Operation 16 TIMER Operation 17 WEEKLY TIMER Operat...

Page 3: ...ler When carrying out repairs accompanying adding refrigerant check the content of the repairs with our service staff Do not attempt to install the air conditioner by your self Incorrect work will res...

Page 4: ...s and other debris accumulate around the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunctions smoke or fire when making contact with...

Page 5: ...eaker OFF Do not touch the metal parts on the inside of the indoor unit as it may result in injury 1 2 6 5 2 4 7 8 3 9 12 10 11 13 14 Air outlet selection switch This setting blows air from upper outl...

Page 6: ...o the following table This switch is useful when the remote controller is missing 12 Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a shor...

Page 7: ...temperature setting 7 MODE selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 15 9 ECONO button ECONO operation page 16 10 SW...

Page 8: ...ld batteries together When the system is not used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception det...

Page 9: ...utton to set the clock to the present time Holding down or button rapidly increases or decreases the time display 5 Press CLOCK button Always point the remote controller at the indoor unit when pushin...

Page 10: ...side this humidity or temperature range may cause a safety device to disable the system Recommended temperature setting For cooling 26 C 28 C For heating 20 C 24 C Mode Operating conditions If operati...

Page 11: ...Each pressing of the button advances the mode setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION...

Page 12: ...peration frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does n...

Page 13: ...st the vertical blades louvers Hold the knob and move the louver You will find a knob on the left side and the right side blades Notes on flap and louvers angle Unless SWING is selected you should set...

Page 14: ...tuation Blowing pattern COOL mode When the room has become fully cool or when one hour has passed since turning on the air conditioner So that air does not come into direct contact with people air is...

Page 15: ...ation POWERFUL Operation cannot be used together with ECONO or QUIET Operation Priority is given to the function of whichever button is pressed last POWERFUL Operation can only be set when the unit is...

Page 16: ...f using a multi system this function will work only when the OUTDOOR UNIT QUIET operation is set on all operated indoor units However if using priority room setting see Note for Multi System page 24 T...

Page 17: ...nnecting outdoor unit NOTE ECONO Operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD ECONO operatio...

Page 18: ...utton changes the setting rapidly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER Operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the pre...

Page 19: ...ither button changes the setting rapidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF T...

Page 20: ...making reservations The use of ON ON ON ON settings for example makes it possible to schedule operating mode and set temperature changes Furthermore by using OFF OFF OFF OFF settings only the turn OF...

Page 21: ...link 4 Press SELECT button to select the desired mode and or will flash Go to STEP 9 if no setting is selected 5 Press NEXT button The weekly mode will be set and blink 6 Press SELECT button to select...

Page 22: ...controller settings just before the operation Both WEEKLY TIMER and ON OFF timer cannot be used at the same time The ON OFF timer has priority if it is set while WEEKLY TIMER is still active WEEKLY T...

Page 23: ...lected day of the week The whole reservation of the selected day of the week will be copied To continue copying the settings to other days of the week repeat STEP 4 and STEP 5 6 Press button Exit copy...

Page 24: ...check for a receiving tone This operation is not effective while WEEKLY TIMER is being set All reservations will be canceled Canceling individual reservations This function can be used for canceling r...

Page 25: ...stallation Please consult your retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGH...

Page 26: ...g If the unit in Room A enters POWERFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduce...

Page 27: ...panel into the grooves of the unit 3 places Attach the string to the right inner side of the front grille Close the panel slowly CAUTION Units Don t touch the metal parts of the indoor unit If you tou...

Page 28: ...utral detergent thinned with lukewarm water then dry them up in the shade It is recommended to clean the air filters every 2 weeks Titanium Apatite Photocatalytic Air Purifying Filter The Titanium Apa...

Page 29: ...ilter contact to the service shop there you bought the air conditioner Dispose of old filters as flammable waste Check that the base stand and other fittings of the outdoor unit are not decayed or cor...

Page 30: ...ring defrost operation The indoor unit gives out odour This happens when smells of the room furniture or cigarettes are absorbed into the unit and discharged with the airflow If this happens we recomm...

Page 31: ...nd the outdoor units Clean the air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still...

Page 32: ...ed to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenance contact the service shop where you bought the air conditioner The maintenance cost...

Page 33: ...32 MEMO...

Page 34: ...0808 HT Two dimensional bar code is a code for manufacturing 3P232453 1 M08B034...

Reviews: