Daikin FVXS25BAVMB Manual Download Page 1

• Indoor Units • R410A • FVXS-BAVMB

1

1

• Split Sky Air • Indoor Units

1

1

Features

I

n

d

o

o

r

 

U

n

i

t

S

p

l

i

t

 

S

k

y

 

A

F

V

X

S

-

B

A

V

M

B

R

4

1

0

A

Compact&stylish

Lightweight and  compact

Can be used as a floor st anding or lower wall applicat ion.   As a floor 
st anding model, it can be semi-recessed or fully recessed without  
loss of  capacity.

A double horizont al air outlet ensures unif orm air flow and 
t emperature distribution

The home leave operat ion saves energy during absence

Air purif ication filt er: deodorises the air and helps t o prevent  bacterial 
and viral propagation

The photocatalyt ic  deodorising air filter:  powerfully decomposes 
cigarett e and pet odours, removes house dust and pollen and 
deactivates bacteria and viruses

Powerful mode can be selected for rapid cooling or heating

Washable front  panel

Indoor unit  silent operation: "Silent" butt on on the remot e control 
lowers the operation sound of  the indoor  unit  by 3dB(A).

Easy to  install

Up to 4 indoor units can be connect ed to 1 Multi outdoor unit .  All 
indoor units are individually controllable with remote control and do 
not need to be installed in the same room or at  the same t ime.  They 
operate simultaneously within the same cooling operation

Daikin remot e controls give you easy  cont rol at  your f ingert ips.

The remote control has a 24-hour timer

The indoor unit also has a start /stop button mounted on the f ront 
panel

Up to 5 indoor units can be operated from a single centralised control

Purpose-designed holder provided for your remote  cont rol

optional

5 steps

standard

MXS

Summary of Contents for FVXS25BAVMB

Page 1: ...se dust and pollen and deactivates bacteria and viruses Powerful mode can be selected for rapid cooling or heating Washable front panel Indoor unit silent operation Silent button on the remote control...

Page 2: ...n Quantity 2 2 2 Air Flow Rate Cooling High m min 8 10 8 30 10 80 Medium m min 6 20 6 30 9 20 Low m min 4 30 4 30 7 70 Silent Operation m min 3 4 3 4 6 7 Heating High m min 9 20 9 20 13 20 Medium m mi...

Page 3: ...2 2 Item Remote control holder Remote control holder Air purification filter Quantity 1 1 1 Item Air purification filter Air purification filter Remote control holder Quantity 1 1 1 Item Heatinsulati...

Page 4: ...Sky Air Indoor Units 4 Indoor Units R410A FVXS BAVMB 2 Specifications Voltage range Minimum 10 Maximum 10 Power Supply Intake Outdoor unit only 2 3 ELECTRICAL SPECIFICATIONS FVXS25BAVMB FVXS35BAVMB F...

Page 5: ...ed ON OFF control DCS301B51 Schedule timer DST301B51 Interface adapter DIII net 3 KRP928A2S Photocatalytic deodorising filter with frame KAZ917B41 Photocatalytic deodorising filter without frame KAZ91...

Page 6: ...ERFUL button for POWERFUL operation 5 TEMPERATURE adjustment buttons It changes the temperature setting 6 ON OFF button Press this button once to start operation Press once again to stop it 7 MODE sel...

Page 7: ...maintenance for performance Wall hole Wall hole for half concealed Terminal strip with earth terminal Liquid pipe J6 4 CuT Gas pipe AA CuT Room temp thermistor Signal transmitter Infrared remote cont...

Page 8: ...3 1 5 Split Sky Air Indoor Units 8 Indoor Units R410A FVXS BAVMB 5 Dimensional drawing centre of gravity 5 2 Centre of gravity 4D036467...

Page 9: ...ld piping Field piping Refrigerant flow Cooling Heating Cross flow fan Cross flow fan Single union joint Single union joint Thermistor on heat exchanger 4D020911B FVK XS50B Indoor unit Heat exchanger...

Page 10: ...FU Fuse H1P H2P H3P Pilot lamp L1S Limit switch M1F M2F Fan motor M1S Swing motor M2S Lower air outlet motor PCB1 PCB4 Printed circuit board R1T R2T Thermistor S6 S302 Connector S1W Operation switch S...

Page 11: ...Cooling H L SL FVKS25B 38 26 23 54 FVKS35B 39 27 24 55 FVKS50B 44 36 33 56 Heat pump Model Sound pressure level Sound power level cooling heating 230V 50Hz Measuring location Cooling Heating H L SL FV...

Page 12: ...level differs with operation and ambient conditions 3 Reference acoustic pressure 0dB 20 Pa Legend 50 60Hz 220 240 220 230V H 50 60Hz 220 240 220 230V L 3D035251A Octave band sound pressure level dB...

Page 13: ...level differs with operation and ambient conditions 3 Reference acoustic pressure 0dB 20 Pa Legend 50 60Hz 220 240 220 230V H 50 60Hz 220 240 220 230V L 3D035251A Octave band sound pressure level dB 0...

Page 14: ...shown here Grid field supply Front panel 50 mm or more from walls on both side Caulk pipe hole gap with putty 70 mm or more Air filter j I Air purifying filter j H Photocatalytic deodorising filter F...