SiBE06-514A
Indoor Unit
Removal Procedure
135
1.5
Removal of the
Heat Exchanger
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work
Step
Procedure
Points
Conduct pump-down
operation and check that
gas has been purged
completely before starting
service work.
Mounting screw M4 × 16
1
Loosen the two screws
to remove the top
discharge grille.
2
Remove the heat
exchanger.
Warning
If refrigerant gas leaks during
service work, ventilate work
area.
(Toxic gas may be generated
when refrigerant gas contacts
with flame.)
3
Disconnect the flared
joint of liquid pipe using
two wrenches.
14/17 double ended wrench
4
Disconnect the flared
joint of gas pipe using
two wrenches.
17/23 double ended wrench
Caution
Do not contaminate any gas
(including air) other than the
specified refrigerant (R-410A)
(Contaminating of air or other
gas causes abnormal
temperature rise in
refrigerating cycle, and this
results in pipe breakage or
personal injuries.)
After pipes are
disconnected, close all pipe
openings with caps to
prevent dust and moisture
from entering pipes.
Summary of Contents for FVKS25BVMB
Page 10: ...SiBE06 514A List of Functions 1 Part 1 List of Functions 1 List of Functions 2 ...
Page 13: ...List of Functions SiBE06 514A 4 List of Functions ...
Page 19: ...Specifications SiBE06 514A 10 Specifications ...
Page 57: ...Control Specification SiBE06 514A 48 Function and Control ...
Page 85: ...Instruction SiBE06 514A 76 System Configuration ...
Page 133: ...Check SiBE06 514A 124 Service Diagnosis ...
Page 171: ...Others SiBE06 514A 162 Others ...
Page 177: ...Wiring Diagrams SiBE06 514A 168 Appendix ...
Page 181: ...SiBE06 514A iv Index ...