Indoor Unit
SiBE01-829
68
Removal Procedure
1.5
Removal of
Electrical Box
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Disconnect the connecting
wires
Preparation
Remove the front grille
according to the “Removal
of Front Grille”.
1
The figure shows the
connections of wire
harnesses.
2
Remove the screw of
the electric wire
retaining plate.
The thermal fuse is a part of
the terminal board.
3
Loosen the screws of
the terminal board and
disconnect the
connecting wires.
4
Pull out the heat
exchanger thermistor.
Terminal board
Electrical box
Electric wire retaining plate
(R8590)
(R8591)
Terminal board
(R8592)
(R8593)
Heat exchanger thermistor