Indoor Unit
SiBE01-829
62
Removal Procedure
1.2
Removal of
Front Panel
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
Open the front panel
over the position where
it will stop.
Preparation
Remove the air filter
according to the “Removal
of Air Filter”.
2
Slide the right rotary
shaft to the left and
release it.
The rotary shaft on the each
side can be removed easily
by sliding each shaft
inwards.
3
Slide the left rotary
shaft to the right and
release it.
4
Remove the front panel.
Caution on Mounting
When mounting the front
panel, fit the right and left
rotary shafts one by one into
the grooves and fully push
them in position.
Left side
Right side
(R8571)
Right side
Rotary shaft
(R8572)
Left side
Rotary shaft
(R8029)
(R8573)
Summary of Contents for FTY25GXV1
Page 1: ...SiBE01 829 Applied Models Non Inverter Pair Heat Pump SPLIT Pair Wall Mounted Type G Series ...
Page 5: ...SiBE01 829 iv Table of Contents Index i Drawings Flow Charts iii ...
Page 11: ...Introduction SiBE01 829 x ...
Page 12: ...SiBE01 829 List of Function 1 Part 1 List of Function 1 Functions 2 ...
Page 15: ...Functions SiBE01 829 4 List of Function ...
Page 16: ...SiBE01 829 Specifications 5 Part 2 Specifications 1 Specifications 6 ...
Page 19: ...Specifications SiBE01 829 8 Specifications ...
Page 49: ...Instructions SiBE01 829 38 Operation Manual ...
Page 69: ...Check SiBE01 829 58 Service Diagnosis ...
Page 111: ...Outdoor Unit SiBE01 829 100 Removal Procedure ...
Page 119: ...Wiring Diagrams SiBE01 829 108 Appendix ...