background image

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

MODELS

FTXV20W1VMA
FTXV25W1VMA
FTXV35W1VMA
FTXV46W1VMA

00_CV_3P683779-1.indd   1

14/01/2022   3:57:41 pm

Summary of Contents for FTXV20W1VMA

Page 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXV20W1VMA FTXV25W1VMA FTXV35W1VMA FTXV46W1VMA 00_CV_3P683779 1 indd 1 14 01 2022 3 57 41 pm ...

Page 2: ...in a quiet neighbourhood Page 18 WEEKLY TIMER Up to 4 timer settings can be saved for each day of the week according to your family s life style The WEEKLY TIMER allows you to set on off times and the desired temperature Page 22 INTELLIGENT EYE The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airflow direction If no one is in the room for more than 20 minutes the op...

Page 3: ...f Parts 5 Preparation Before Operation 9 Basic Operation AUTO DRY COOL HEAT FAN Operation 11 Adjusting the Airflow Rate 12 Adjusting the Airflow Direction 13 Useful Functions COMFORT AIRFLOW Operation 14 INTELLIGENT EYE Operation 15 POWERFUL Operation 17 ECONO OUTDOOR UNIT QUIET Operation 18 TIMER Operation ON OFF TIMER Operation 19 WEEKLY TIMER Operation 22 Care Care and Cleaning 28 When the Need...

Page 4: ... due to contact with the air conditioner s high speed fan blades Do not attempt to repair dismantle reinstall or modify the air conditioner yourself as this may result in water leakage electric shock or fire hazards Do not use flammable spray near the air conditioner or otherwise fire may result Do not use a refrigerant other than the one indicated on the outdoor unit R32 when installing moving or...

Page 5: ...y or property damage may result Do not locate obstacles in the route The panel may fall and injury or property damage may result Do not bend or damage the wires The wires may be broken and the panel may fall and injury or property damage may result Do not put objects on the panel or otherwise production malfunctioning may result Do not use an unstable stand at the time of operating or maintaining ...

Page 6: ...n Press once again to stop it For the operation mode setting refer to the following table Mode Temperature setting Airflow rate AUTO 25 0 C AUTO This switch can be used when the remote controller is missing or out of batteries Air inlet Front panel Air outlet Louvres vertical blades The louvres are inside of the air outlet Page 13 Flap horizontal blade Page 13 Model name Room temperature sensor De...

Page 7: ...er unit wire Drain hose Air outlet Air inlet back and side Earth terminal inside For 46 class For 20 25 35 class Refrigerant pipes and inter unit wire Earth terminal inside Drain hose Air outlet Air inlet back and side Outdoor temperature sensor back Deodorizing filter enzyme blue 01_EN_3P683779 1 indd 6 01 02 2022 10 11 10 am ...

Page 8: ...bout 7m FAN setting button Selects the airflow rate setting Page 12 POWERFUL button POWERFUL operation Page 17 Model name ARC466A26 Display LCD Displays the current settings In this illustration each section is shown with all its displays on for the purpose of explanation TEMPERATURE adjustment button Changes the temperature setting Page 11 ON OFF button Press this button once to start operation P...

Page 9: ...ANCEL button Cancels the timer setting Page 19 20 Cannot be used for the WEEKLY TIMER operation SELECT button Changes the clock ON OFF TIMER and WEEKLY TIMER settings ECONO QUIET button ECONO OUTDOOR UNIT QUIET operation Page 18 SWING button Adjusts the airflow direction Page 13 WEEKLY button PROGRAMME button COPY button BACK button NEXT button WEEKLY TIMER operation Page 22 ON TIMER button Page 1...

Page 10: ...time is 1 year Both batteries should be replaced at the same time Be sure to replace them with new size AAA LR03 alkaline batteries When battery power has run out the LCD will begin blinking as an alert that the batteries need replacing In some cases when battery consumption is accelerated owing usage conditions signal reception may decline before the LCD begins blinking The batteries supplied wit...

Page 11: ...esent time Holding down or rapidly increases or decreases the displayed time 5 Press Point the remote controller at the indoor unit when pressing the buttons blinks NOTE Note on setting the clock If the indoor unit s internal clock is not set to the correct time the ON OFF TIMER and WEEKLY TIMER will not operate punctually 01_EN_3P683779 1 indd 10 01 02 2022 10 11 12 am ...

Page 12: ...l to bring the indoor temperature to user setting level Note on COOL operation This air conditioner cools the room by releasing the heat in the room outside Therefore the cooling performance of the air conditioner may be degraded if the outdoor temperature is high Note on DRY operation Eliminates humidity while maintaining the indoor temperature as much as possible It automatically controls temper...

Page 13: ...ing or autumn turn off the circuit breaker The air conditioner always consumes a small amount of electricity even while it is not operating You can adjust the airflow rate to increase your comfort To adjust the airflow rate setting Press Each pressing of the button changes the airflow rate setting in sequence AUTO Indoor unit quiet Airflow rate 1 5 Low to High When the airflow is set to quiet opera...

Page 14: ...nd and appear on the LCD The flap and louvres move in turn To cancel 3 D airflow press either or again The flap or louvres will stop moving To set the flap or louvres at the desired position This function is effective while the flap or louvres are in auto swing mode Press and when the flap or louvres reach the desired position In the 3 D airflow the flap and louvres move in turn or disappears from...

Page 15: ... is pressed last COMFORT AIRFLOW Operation The flow of air will be in the upward direction while in COOL operation and in the downward direction while in HEAT operation which will provide a comfortable wind that will not come in direct contact with people To start Press Comfort appears on the LCD COOL and DRY operation HEAT operation FAN operation Flap direction Goes up Goes down Not available Air...

Page 16: ...on the LCD The INTELLIGENT EYE lamp lights green Display blank No Setting Do not blow directly on people Blow directly on people When the flap horizontal blade is swinging selecting any of the modes above will cause the flap horizontal blade to stop The lamp lights when human movement is detected To cancel Press Sensor until no icon is displayed The INTELLIGENT EYE lamp goes off NOTE Note on INTEL...

Page 17: ... in front of the sensor as the sensor judges that there are people in both areas Due to the position of the sensor people might be exposed to the airflow of the indoor unit if they are close to the front side of the indoor unit If there are people close to the front side of the indoor unit or in both areas it is recommended to use the COMFORT AIRFLOW and INTELLIGENT EYE operations simultaneously U...

Page 18: ...ase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation To maximise the cooling heating effect the capacity of outdoor unit increases and the airflow rate becomes fixed at the maximum setting The temperature and airflow settings cannot be changed In DRY operation The temperature setting is lowered...

Page 19: ...ration is performed with lower power and therefore may not provide a sufficient cooling heating effect Pressing causes the settings to be cancelled and disappears from the LCD If the power consumption level is already low switching to ECONO operation will not reduce the power consumption Notes on OUTDOOR UNIT QUIET operation Even if the operation is stopped by using the remote controller or the in...

Page 20: ...g reaches the point you like Each pressing of either button increases or decreases the time setting by 10 minutes Holding down either button changes the setting rapidly 3 Press again and setting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and setting time disappear from the LCD and day of the week appear on the LCD The TIMER lamp goes off NOTE Note on TIMER operatio...

Page 21: ... 3 Press again and setting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and setting time disappear from the LCD and day of the week appear on the LCD The TIMER lamp goes off ON OFF TIMER combination To combine A sample setting for combining the 2 timers is shown below Example Present time 23 00 The unit is operating OFF TIMER at 0 00 ON TIMER at 14 00 Combined NOTE N...

Page 22: ...FF TIMER Page 19 20 Timer display mode cannot be changed while or are blinking Press or to stop the blinking Display Combining display modes Different display modes 24 HOUR ON OFF TIMER and COUNT UP DOWN ON OFF TIMER can be used for the ON TIMER and OFF TIMER simultaneously Example Present time 22 00 The unit is operating OFF TIMER at 1 00 3 hours after persent time ON TIMER at 6 00 8 hours after ...

Page 23: ...e for Monday Page 25 6 00 8 30 17 30 22 00 25 0 C 27 0 C Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings for programmes 1 4 Page 23 8 00 10 00 19 00 21 00 27 0 C 27 0 C 25 0 C ON ON OFF OFF ON OFF OFF ON Programme 1 Programme 2 Programme 3 Programme 4 Up to 4 reservations per day and 28 reservations per week can be set using the W...

Page 24: ... day 2 Press to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set and blink 4 Press to select the desired mode Pressing changes the or setting in sequence ON TIMER OFF TIMER blank No Setting Pressing puts the sequence in reverse In case the reservation has already ...

Page 25: ...ation is activated The TIMER lamp lights orange Display A reservation made once can be easily copied and the same settings used for another day of the week Refer to Copy mode Page 25 NOTE Notes on WEEKLY TIMER operation Do not forget to set the clock on the remote controller first Page 10 The day of the week ON OFF TIMER mode time and set temperature only for ON TIMER mode can be set with the WEEK...

Page 26: ...the selected day of the week will be copied 4 Press to select the destination day of the week 5 Press The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week will be copied To continue copying the settings to other days of the week repeat STEP 4 and STEP 5 6 Press to complete the setting appears on the LCD and WEEKLY TIMER operation is a...

Page 27: ... Proceed to Setting mode STEP 4 Page 23 3 Press to exit the confirmation mode appears on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display To deactivate WEEKLY TIMER operation Press while is displayed on the LCD disappears from the LCD The TIMER lamp goes off To reactivate the WEEKLY TIMER operation press again If a reservation deactivated with is activated once ...

Page 28: ...rvations for each day of the week This function can be used for deleting reservations for each day of the week It can be used while confirming or setting reservations 1 Press The day of the week and the reservation number will be displayed 2 Press to select the day of the week to be deleted 3 Hold for about 5 seconds The reservation of the selected day of the week will be deleted 4 Press If there ...

Page 29: ...ble 1 or to purchase the another type contact the dealer where you bought the air conditioner The method of cleaning and replacement of the filters may differ depending on the model Refer to the label attached to the separately sold filters themselves Table 1 Item Part No Air quality filter enzyme blue with PM2 5 without frame set of 2 BAFP094A43 Deodorizing filter enzyme blue without frame set of...

Page 30: ... water or clean them with vacuum cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with lukewarm water then dry them up in the shade 4 Reattach the filters 5 Close the front panel slowly Press the panel at both sides and the centre Make sure that the front panel is securely fixed Care and Cleani...

Page 31: ...n be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years Do not wiring out the filter when removing water from it Air quality filter enzyme blue with PM2 5 Blue White Dust collection filter PM 2 5 White Do not wash the filters as this will reduce their efficiency It is recommended to replace it once every 6 months Replacement Remove each filter fro...

Page 32: ...ake out the batteries from the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist in addition to regular cleaning by the user For specialist maintenance please contact the dealer where you bough...

Page 33: ... changes Whistling sound This sound is generated when refrigerant flows during defrosting operation Clicking sound during operation or idle time This sound is generated when the refrigerant control valves or the electrical parts operate Clopping sound This sound is heard from the inside of the air conditioner when the exhaust fan is activated while the room doors are closed Open the window or turn...

Page 34: ...ed Immediately after the air conditioner is stopped The outdoor unit fan continues rotating for about another 1 minute to protect the system While the air conditioner is not in operation When the outdoor temperature is high the outdoor unit fan may start rotating to protect the system The room does not cool down warm up Case Description what to check Air does not come out In HEATING operation The ...

Page 35: ...r heating or lead to equipment failure Even when the LCD is blinking the OFF button remains functional Other electric devices start operating If the remote controller activates other electric devices move them away or consult your dealer Air has an odour Case Description what to check The air conditioner gives off an odour The room odour absorbed in the unit is discharged with the airflow We recom...

Page 36: ...ed An abnormal sound is heard during operation The circuit breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn off the circuit breaker and call your dealer After a power failure The air conditioner automatically resumes operation in about 3 minutes Plea...

Page 37: ...AULT C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTROL IN COOLING H0 SENSOR FAULT H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR...

Page 38: ...37 MEMO 01_EN_3P683779 1 indd 37 01 02 2022 10 11 19 am ...

Page 39: ...01_EN_3P683779 1 indd 38 01 02 2022 10 11 19 am ...

Page 40: ...The two dimensional bar code is a manufacturing code Quick Reference MODE On Off FAN Temp Mode Swing 3P683779 1 M22N001 2201 HT 00_CV_3P683779 1 indd 2 14 01 2022 3 57 42 pm ...

Page 41: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXV50W1VMA FTXV60W1VMA FTXV71W1VMA 00_CV_3P683779 2 indd 1 18 01 2022 2 14 49 pm ...

Page 42: ...el of the outdoor unit This function is useful to maintain a quiet neighbourhood Page 18 WEEKLY TIMER Up to 4 timer settings can be saved for each day of the week according to your family s life style The WEEKLY TIMER allows you to set on off times and the desired temperature Page 22 INTELLIGENT EYE The INTELLIGENT EYE sensor detects human movement in a room If no one is in the room for more than ...

Page 43: ...f Parts 5 Preparation Before Operation 9 Basic Operation AUTO DRY COOL HEAT FAN Operation 11 Adjusting the Airflow Rate 12 Adjusting the Airflow Direction 13 Useful Functions COMFORT AIRFLOW Operation 14 INTELLIGENT EYE Operation 15 POWERFUL Operation 17 ECONO OUTDOOR UNIT QUIET Operation 18 TIMER Operation ON OFF TIMER Operation 19 WEEKLY TIMER Operation 22 Care Care and Cleaning 28 When the Need...

Page 44: ...an blades Do not attempt to repair dismantle reinstall or modify the air conditioner yourself as this may result in water leakage electric shock or fire hazards Do not use flammable spray near the air conditioner or otherwise fire may result Do not use a refrigerant other than the one indicated on the outdoor unit R32 when installing moving or repairing Using other refrigerants may cause trouble o...

Page 45: ...y or property damage may result Do not locate obstacles in the route The panel may fall and injury or property damage may result Do not bend or damage the wires The wires may be broken and the panel may fall and injury or property damage may result Do not put objects on the panel or otherwise production malfunctioning may result Do not use an unstable stand at the time of operating or maintaining ...

Page 46: ... Press once again to stop it For the operation mode setting refer to the following table Mode Temperature setting Airflow rate AUTO 25 0 C AUTO This switch can be used when the remote controller is missing or out of batteries Air inlet Front panel Air outlet Louvres vertical blades The louvres are inside of the air outlet Page 13 Flaps horizontal blades Page 13 Model name Room temperature sensor D...

Page 47: ...nel Outdoor Unit Air filter Outdoor temperature sensor back Deodorizing filter enzyme blue Earth terminal inside Drain hose Refrigerant pipes and inter unit wire Air inlet back and side Air outlet 01_EN_3P683779 2 indd 6 01 02 2022 10 14 32 am ...

Page 48: ...FAN setting button Selects the airflow rate setting Page 12 POWERFUL button POWERFUL operation Page 17 Model name ARC466A28 Display LCD Displays the current settings In this illustration each section is shown with all its displays on for the purpose of explanation TEMPERATURE adjustment button Changes the temperature setting Page 11 ON OFF button Press this button once to start operation Press onc...

Page 49: ... TIMER CANCEL button Cancels the timer setting Page 19 20 Cannot be used for the WEEKLY TIMER operation SELECT button Changes the clock ON OFF TIMER and WEEKLY TIMER settings ECONO QUIET button ECONO OUTDOOR UNIT QUIET operation Page 18 SWING button Adjusts the airflow direction Page 13 WEEKLY button PROGRAMME button COPY button BACK button NEXT button WEEKLY TIMER operation Page 22 ON TIMER butto...

Page 50: ...s should be replaced at the same time Be sure to replace them with new size AAA LR03 alkaline batteries When battery power has run out the LCD will begin blinking as an alert that the batteries need replacing In some cases when battery consumption is accelerated owing usage conditions signal reception may decline before the LCD begins blinking The batteries supplied with the remote controller are ...

Page 51: ...esent time Holding down or rapidly increases or decreases the displayed time 5 Press Point the remote controller at the indoor unit when pressing the buttons blinks NOTE Note on setting the clock If the indoor unit s internal clock is not set to the correct time the ON OFF TIMER and WEEKLY TIMER will not operate punctually 01_EN_3P683779 2 indd 10 01 02 2022 10 14 34 am ...

Page 52: ...l to bring the indoor temperature to user setting level Note on COOL operation This air conditioner cools the room by releasing the heat in the room outside Therefore the cooling performance of the air conditioner may be degraded if the outdoor temperature is high Note on DRY operation Eliminates humidity while maintaining the indoor temperature as much as possible It automatically controls temper...

Page 53: ...g or autumn turn off the circuit breaker The air conditioner always consumes a small amount of electricity even while it is not operating You can adjust the airflow rate to increase your comfort To adjust the airflow rate setting Press Each pressing of the button changes the airflow rate setting in sequence AUTO Indoor unit quiet Airflow rate 1 5 Low to High When the airflow is set to quiet operati...

Page 54: ... and appear on the LCD The flaps and louvres move in turn To cancel 3 D airflow press either or again The flaps or louvres will stop moving To set the flaps or louvres at the desired position This function is effective while the flaps or louvres are in auto swing mode Press and when the flaps or louvres reach the desired position In the 3 D airflow the flaps and louvres move in turn or disappears ...

Page 55: ...low rate AUTO To cancel Press Comfort again disappears from the LCD The flaps will return to the position in memory form before COMFORT AIRFLOW operation Comfort NOTE Notes on COMFORT AIRFLOW Operation The flaps position will change preventing air from blowing directly on the occupants of the room POWERFUL operation and COMFORT AIRFLOW operation cannot be used at the same time The airflow rate wil...

Page 56: ...r s detection area This sensor can detect undesirable objects Do not hit or violently push the INTELLIGENT EYE sensor This can lead to damage and malfunction To start Press Sensor and select the desired model Each time the button is pressed a different setting option is displayed on the LCD The INTELLIGENT EYE lamp lights green blank No Setting Intelligent eye The lamp lights when human movement i...

Page 57: ...ration from the set temperature This operation decreases the airflow rate slightly in FAN operation only NOTE Notes on INTELLIGENT EYE operation Application range is as follows 90 55 7m 55 Vertical angle 90 Side view Horizontal angle 110 Top view 7m The sensor may not detect moving objects further than 7m away Please see the application range Sensor detection sensitivity changes according to the i...

Page 58: ...ase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation To maximise the cooling heating effect the capacity of outdoor unit increases and the airflow rate becomes fixed at the maximum setting The temperature and airflow settings cannot be changed In DRY operation The temperature setting is lowered...

Page 59: ...ration is performed with lower power and therefore may not provide a sufficient cooling heating effect Pressing causes the settings to be cancelled and disappears from the LCD If the power consumption level is already low switching to ECONO operation will not reduce the power consumption Notes on OUTDOOR UNIT QUIET operation Even if the operation is stopped by using the remote controller or the in...

Page 60: ...g reaches the point you like Each pressing of either button increases or decreases the time setting by 10 minutes Holding down either button changes the setting rapidly 3 Press again and setting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and setting time disappear from the LCD and day of the week appear on the LCD The TIMER lamp goes off NOTE Note on TIMER operatio...

Page 61: ... 3 Press again and setting time appear on the LCD The TIMER lamp lights orange Display To cancel Press and setting time disappear from the LCD and day of the week appear on the LCD The TIMER lamp goes off ON OFF TIMER combination To combine A sample setting for combining the 2 timers is shown below Example Present time 23 00 The unit is operating OFF TIMER at 0 00 ON TIMER at 14 00 Combined NOTE N...

Page 62: ...FF TIMER Page 19 20 Timer display mode cannot be changed while or are blinking Press or to stop the blinking Display Combining display modes Different display modes 24 HOUR ON OFF TIMER and COUNT UP DOWN ON OFF TIMER can be used for the ON TIMER and OFF TIMER simultaneously Example Present time 22 00 The unit is operating OFF TIMER at 1 00 3 hours after present time ON TIMER at 6 00 8 hours after ...

Page 63: ...e for Monday Page 25 6 00 8 30 17 30 22 00 25 0 C 27 0 C Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings for programmes 1 4 Page 23 8 00 10 00 19 00 21 00 27 0 C 27 0 C 25 0 C ON ON OFF OFF ON OFF OFF ON Programme 1 Programme 2 Programme 3 Programme 4 Up to 4 reservations per day and 28 reservations per week can be set using the W...

Page 64: ...the desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set and blink 4 Press to select the desired mode Pressing changes the or setting in sequence ON TIMER OFF TIMER blank No Setting Pressing puts the sequence in reverse In case the reservation has already been set selecting blan...

Page 65: ...ation is activated The TIMER lamp lights orange Display A reservation made once can be easily copied and the same settings used for another day of the week Refer to Copy mode Page 25 NOTE Notes on WEEKLY TIMER operation Do not forget to set the clock on the remote controller first Page 10 The day of the week ON OFF TIMER mode time and set temperature only for ON TIMER mode can be set with the WEEK...

Page 66: ... week will be copied 4 Press to select the destination day of the week 5 Press The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week will be copied To continue copying the settings to other days of the week repeat STEP 4 and STEP 5 6 Press to complete the setting appears on the LCD and WEEKLY TIMER operation is activated NOTE Note on C...

Page 67: ... Proceed to Setting mode STEP 4 Page 23 3 Press to exit the confirmation mode appears on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange Display To deactivate WEEKLY TIMER operation Press while is displayed on the LCD disappears from the LCD The TIMER lamp goes off To reactivate the WEEKLY TIMER operation press again If a reservation deactivated with is activated once ...

Page 68: ...rvations for each day of the week This function can be used for deleting reservations for each day of the week It can be used while confirming or setting reservations 1 Press The day of the week and the reservation number will be displayed 2 Press to select the day of the week to be deleted 3 Hold for about 5 seconds The reservation of the selected day of the week will be deleted 4 Press If there ...

Page 69: ...ble 1 or to purchase the another type contact the dealer where you bought the air conditioner The method of cleaning and replacement of the filters may differ depending on the model Refer to the label attached to the separately sold filters themselves Table 1 Item Part No Air quality filter enzyme blue with PM2 5 without frame set of 2 BAFP094A43 Deodorizing filter enzyme blue without frame set of...

Page 70: ...acuum cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with lukewarm water then dry them up in the shade Be sure to remove the filter small Refer to Filter small on the next page 4 Reattach the filters 5 Close the front panel slowly Press the panel at both sides and the centre Make sure that th...

Page 71: ...de This filter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years Do not wiring out the filter when removing water from it Air quality filter enzyme blue with PM2 5 Blue White Dust collection filter PM 2 5 White Do not wash the filters as this will reduce their efficiency It is recommended to replace it once every 6 months Replacement Remov...

Page 72: ...ake out the batteries from the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist in addition to regular cleaning by the user For specialist maintenance please contact the dealer where you bough...

Page 73: ...e Clopping sound This sound is heard from the inside of the air conditioner when the exhaust fan is activated while the room doors are closed Open the window or turn off the exhaust fan The outdoor unit emits water or steam In HEAT operation The frost on the outdoor unit melts into water or steam when the air conditioner is in defrosting operation In COOL or DRY operation Moisture in the air conde...

Page 74: ...e and confirm that the lamps blink If the lamps stop blinking after the above steps there is no malfunction The air conditioner does not stop operating Case Description what to check The air conditioner continues operating even after operation is stopped Immediately after the air conditioner is stopped The outdoor unit fan continues rotating for about another 1 minute to protect the system While t...

Page 75: ...r heating or lead to equipment failure Even when the LCD is blinking the OFF button remains functional Other electric devices start operating If the remote controller activates other electric devices move them away or consult your dealer Air has an odour Case Description what to check The air conditioner gives off an odour The room odour absorbed in the unit is discharged with the airflow We recom...

Page 76: ...or damaged An abnormal sound is heard during operation The circuit breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn off the circuit breaker and call your dealer After a power failure The air conditioner automatically resumes operation in about 3 minu...

Page 77: ...AULT C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTROL IN COOLING H0 SENSOR FAULT H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR...

Page 78: ...37 MEMO 01_EN_3P683779 2 indd 37 01 02 2022 10 14 41 am ...

Page 79: ...01_EN_3P683779 2 indd 38 01 02 2022 10 14 41 am ...

Page 80: ...3P683779 2 M22N002 2201 HT The two dimensional bar code is a manufacturing code Quick Reference MODE On Off FAN Temp Mode Swing 00_CV_3P683779 2 indd 2 18 01 2022 2 14 50 pm ...

Page 81: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXM20QVMA FTXM25QVMA FTXM35QVMA FTXM46QVMA FTKM20QVMA FTKM25QVMA FTKM35QVMA FTKM46QVMA 00_CV_3P372379 1C indd 1 7 9 2014 11 07 13 AM ...

Page 82: ...ood Page 19 INTELLIGENT EYE Page 16 WEEKLY TIMER Up to 4 timer settings can be saved for each day of the week according to your family s life style The WEEKLY TIMER allows you to set on off times and the desired temperature Page 23 01_EN_3P372379 1C indd 1 7 9 2014 11 08 03 AM The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airrflow direction If no one is in the ro...

Page 83: ...Functions INTELLIGENT EYE Operation 16 POWERFUL Operation 18 ECONO OUTDOOR UNIT QUIET Operation 19 TIMER Operation ON OFF TIMER Operation 20 WEEKLY TIMER Operation 23 Care Care and Cleaning 29 When the Need Arises FAQ 34 Troubleshooting 35 01_EN_3P372379 1C indd 2 7 9 2014 11 08 06 AM ECONO limiting the maximum power consumption It is useful when using theair conditioner and other electrical devic...

Page 84: ...repairing Using other refrigerants may cause trouble or damage to the unit and personal injury To avoid electric shocks do not operate with wet hands Beware of in case of refrigerant leakage If the air conditioner is not operating correctly i e not generating cool or warm air refrigerant leakage could be the cause Consult your dealer for assistance The refrigerant within the air conditioner is saf...

Page 85: ...nimals which can enter the unit Once inside the unit such animals can cause malfunctions smoke or if they come into contact with electrical parts Do not place objects around the indoor unit Doing so may have an adverse on the performance product quality and life of the air conditioner Installation site To install the air conditioner in the following types of environments consult your dealer Places...

Page 86: ...ion and energy saving operation Panel tab Display ON OFF Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a short beep Operation start beep beep Settings changed beep Operation stop beeeeep Operation lamp green TIMER lamp orange INTELLIGENT EYE lamp green P Indoor Unit ON OFF switch Push this switch once to start operation Push once again...

Page 87: ... Air filter For 20 25 35 class For 46 class Air outlet Air outlet Air inlet back and side Air inlet back and side Refrigerant piping and inter unit wiring Refrigerant piping and inter unit wiring Model name plate Model name plate Earth terminal inside Earth terminal inside Drain hose Drain hose Outdoor temperature sensor back Outdoor temperature sensor back ...

Page 88: ...bout 7m FAN setting button Page 14 POWERFUL button POWERFUL operation Page 18 HEAT PUMPmodel ARC466A26 COOLING ONLY model ARC466A27 Display LCD Displays the current settings In this illustration each section is shown with all its displays on for the purpose of explanation TEMPERATURE adjustment button Changes the temperature setting Page 12 ON OFF button Press this button once to start operation P...

Page 89: ...button Cancels the timer setting Page 20 21 Cannot be used for the WEEKLY TIMER operation SELECT button Changes the clock ON OFF TIMER and WEEKLY TIMER settings ECONO QUIET button ECONO OUTDOOR UNIT QUIET operation Page 19 SWING button Page 13 WEEKLY button PROGRAMME button COPY button BACK button NEXT button WEEKLY TIMER operation Page 23 ON TIMER button Page 20 CLOCK button Page 10 01_EN_3P37237...

Page 90: ...sition Position and correctly 2 3 1 Remote controller holder Remote controller Screws NOTE Notes on batteries When replacing the batteries use batteries of the same type and replace both old batteries together The batteries will last for about 1 year If the remote controller display begins to fade and the possible transmission range becomes shorter within a year however replace both batteries with...

Page 91: ...ock 1 Press is displayed on the LCD and blink 2 Press to set the current day of the week 3 Press blinks 4 Press to set the clock to the present time Holding down or rapidly increases or decreases the displayed time 5 Press Point the remote controller at the indoor unit when pressing the buttons blinks 01_EN_3P372379 1C indd 10 7 9 2014 11 08 16 AM The remote controller may differ from some models ...

Page 92: ...ayed on the LCD The OPERATION lamp lights green To stop operation Press again disappears from the LCD The OPERATION lamp goes off AUTO DRY COOL HEAT FAN Operation NOTE Notes on AUTO operation In AUTO operation the system selects an appropriate operation mode COOL or HEAT based on the indoor temperature and starts the operation The system automatically reselects setting at a regular interval to bri...

Page 93: ...tting at a moderate level helps save energy Recommended temperature setting For cooling 26 0 28 0 C For heating 20 0 24 0 C Cover windows with a blind or a curtain Blocking sunlight and air from outdoors increases the cooling heating effect Page 31 If you are not going to use the air conditioner for a long period for example in spring or autumn turn off the circuit breaker The air conditioner alwa...

Page 94: ...ed To start auto swing Press is displayed on the LCD Press is displayed on the LCD The louvres vertical blades will begin to swing Press and and are displayed on the LCD or again s s e r P and reach the desired position or disappears from the LCD 01_EN_3P372379 1C indd 13 7 9 2014 11 08 19 AM ...

Page 95: ... quiet operation starts and noise from the indoor unit will become quieter AUTO COOL HEAT and FAN operation DRY operation changed NOTE throughout the room preventing areas of cold and hot developing 01_EN_3P372379 1C indd 14 7 9 2014 11 08 20 AM Movable range of the flap COOL DRY HEAT FAN ONLY ...

Page 96: ...ction while in HEAT operation which will provide a comfortable wind that will not come in direct contact with people To cancel COMFORT AIRFLOW operation To start COMFORT AIRFLOW operation Press Comfort is displayed on the LCD COOL and DRY operation HEAT operation FAN ONLY operation Flap direction Goes up Goes down Not available AUTO Press again disappears from the LCD Notes on COMFORT AIRFLOW Oper...

Page 97: ... directly on people The lamp lights when human movement is detected no one is detected in the room for more than 20 minutes the unit automatically enters energy saving operation Do not place large objects near the INTELLIGENT EYE sensor Also keep heating units and humidifiers outside the sensor s detection area This sensor can detect undesirable objects Do not hit or violently push the INTELLIGENT...

Page 98: ...m 55 Vertical angle 90 Side view Horizontal angle 110 Top view 7m While the air conditioner is in INTELLIGENT EYE operation the louvres adjust the direction if there are people in the sensing areas of the INTELLIGENT EYE so that the leftward or rightward will not be directed to the people If no people are detected in either area 1 or 2 for 20 minutes the air conditioner switches to the energy savi...

Page 99: ...in disappears from the LCD NOTE Notes on POWERFUL operation Pressing causes the settings to be cancelled and disappears from the LCD POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation In DRY operation In FAN operation Regarding the combination of POWERFUL and ...

Page 100: ...k No Setting Combination To cancel operation Press until no icon is displayed NOTE Notes on ECONO operation Pressing causes the settings to be cancelled and disappears from the LCD If the power consumption level is already low switching to ECONO operation will not reduce the power consumption Notes on OUTDOOR UNIT QUIET operation Even if the operation is stopped by using the remote controller or t...

Page 101: ...her button increases or decreases the time setting by 10 minutes Holding down either button changes the setting rapidly 3 Press again and setting time are displayed on the LCD The TIMER lamp lights orange Display To cancel ON TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off NOTE Notes on TIMER operation When TIMER is...

Page 102: ...ting rapidly 3 Press again and setting time are displayed on the LCD The TIMER lamp lights orange To cancel OFF TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining the 2 timers is shown below Example Present time 23 00 The unit operating OFF TIMER at 0 00 ...

Page 103: ...imer display mode cannot be changed while or are blinking Press or to stop the blinking Combining display modes Different display modes 24 HOUR ON OFF TIMER and COUNT UP DOWN ON OFF TIMER can be used for the ON TIMER and OFF TIMER simultaneously Example Present time 22 00 unit is in operation OFF TIMER at 1 00 3 hours after present time ON TIMER at 6 00 8 hours after present time Combined NOTE Not...

Page 104: ...to Friday because these settings are the same as those for Monday Page 26 6 00 8 30 17 30 22 00 25 0 C 27 0 C Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings for programmes 1 4 Page 24 8 00 10 00 19 00 21 00 27 0 C 27 0 C 25 0 C ON ON OFF OFF ON OFF OFF ON Programme 1 Programme 2 Programme 3 Programme 4 Up to 4 reservations per da...

Page 105: ...t day will be displayed 1 to 4 settings can be made per day 2 Press to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set and blink 4 Press to select the desired mode Pressing changes the or setting in sequence ON TIMER OFF TIMER blank No Setting In case the reserva...

Page 106: ... check for a receiving tone and blinking of the OPERATION lamp is displayed on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange A reservation made once can be easily copied and the same settings used for another day of the week Refer to Copy mode Page 26 NOTE Notes on WEEKLY TIMER operation Page 10 The day of the week ON OFF TIMER mode time and set temperature only for ...

Page 107: ...d day of the week will be copied 4 Press to select the destination day of the week 5 Press The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week will be copied To continue copying the settings to other days of the week repeat STEP 4 and STEP 5 6 Press to complete the setting is displayed on the LCD and WEEKLY TIMER operation is activat...

Page 108: ... mode Proceed to Setting mode STEP 4 Page 24 3 Press is displayed on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange To deactivate WEEKLY TIMER operation s s e r P while is displayed on the LCD disappears from the LCD The TIMER lamp goes off To reactivate the WEEKLY TIMER operation press again If a reservation deactivated with is activated once again the last reservati...

Page 109: ...The selected reservation will be deleted 6 Press If there are still other reservations WEEKLY TIMER operation will be activated Reservations for each day of the week This function can be used for deleting reservations for each day of the week 1 Press to select the day of the week to be deleted 2 Hold for about 5 seconds The reservation of the selected day of the week will be deleted All reservatio...

Page 110: ...t use any of the following Water hotter than 40 0 C Volatile liquid such as benzene petrol and thinner Polishing compounds Rough materials such as a scrubbing brush Front panel Wipe it with a soft damp cloth If dirty Page 30 Once every 2 weeks Page 31 Indoor unit Outdoor unit and Remote controller Wipe them with a soft cloth If dirty Cleaning Replacement Once every 6 months Once every 3 years Page...

Page 111: ...d pull it toward you This will disconnect the front panel shaft on one side Disconnect the front panel shaft on the other side in the same manner 3 Clean the front panel Wipe it with a soft damp cloth Only neutral detergent may be used In case of washing the panel with water wipe it with a dry soft cloth and let it dry in the shade after washing 4 Attach the front panel Align the front panel shaft...

Page 112: ...le upwards then pull it down 3 water or clean them with a vacuum cleaner 2 weeks If the dust does not come off easily lukewarm water then let them dry in the shade Be sure to remove the titanium apatite photocatalytic Titanium apatite on the next page 4 5 Close the front panel slowly Page 30 2 Pull down 1 Push ...

Page 113: ...hem dry in the shade Replacement frame and attach a new one frame when replacing the titanium apatite properly set in thetabs 4 Set the titanium apatite photocatalytic air purifying 5 were Page 31 6 Close the front panel slowly Page 30 NOTE cannot deodorise the air cannot clean the air results in poor heating or cooling may cause odour the dealer where you bought the air conditioner Item Titanium ...

Page 114: ...rom the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist in addition to regular cleaning by the user For specialist maintenance please contact the dealer where you bought the air conditioner T...

Page 115: ...ink as a result of temperature changes Whistling sound This sound is generated when refrigerant during defrosting operation Clicking sound during operation or idle time This sound is generated when the refrigerant control valves or the electrical parts operate Clopping sound This sound is heard from the inside of the air conditioner when the exhaust fan is activated while the room doors are closed...

Page 116: ... operation and after turning off the circuit breaker remove the obstruction Then restart operation with the remote controller If the OPERATION lamp is still blinking check the error code and consult your dealer Page 38 The air conditioner does not stop operating Case Description what to check The air conditioner continues operating even after operation is stopped Immediately after the air conditio...

Page 117: ... to check The air conditioner gives off an odour We recommend you to have the indoor unit cleaned Please consult your dealer Others Case Description what to check The air conditioner suddenly starts behaving strangely during operation The air conditioner may malfunction due to lightning or radio If the air conditioner malfunctions turn off the power with the circuit breaker and restart the operati...

Page 118: ...e power cord is abnormally hot or damaged An abnormal sound is heard during operation The circuit breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn off the circuit breaker and call your dealer After a power failure The air conditioner automatically re...

Page 119: ...UTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARDFAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTROL IN COOLING H0 SENSOR FAULT H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR H8 DC CURRENT SENSOR FAULT H9 FAULTY SUCTION AIR TEMPERATURE SENSOR J3 FAULTY DISCHARGE PIP...

Page 120: ...3P372379 4D M15N075 1507 Quick Reference 00_CV_3P372379 1C indd 2 30 6 2015 AM MODE On Off FAN Temp Mode Swing ...

Page 121: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS 00_CV_3P372379 1C indd 1 7 9 2014 11 07 13 AM FTXM50QVMA FTXM60QVMA FTXM71QVMA FTKM50QVMA FTKM60QVMA FTKM71QVMA ...

Page 122: ... outdoor unit This function is useful to maintain a quiet neighbourhood Page 19 INTELLIGENT EYE Page 16 WEEKLY TIMER Up to 4 timer settings can be saved for each day of the week according to your family s life style The WEEKLY TIMER allows you to set on off times and the desired temperature Page 23 01_EN_3P372379 1C indd 1 7 9 2014 11 08 03 AM The INTELLIGENT EYE sensor detects human movement in a...

Page 123: ...Functions INTELLIGENT EYE Operation 16 POWERFUL Operation 18 ECONO OUTDOOR UNIT QUIET Operation 19 TIMER Operation ON OFF TIMER Operation 20 WEEKLY TIMER Operation 23 Care Care and Cleaning 29 When the Need Arises FAQ 34 Troubleshooting 35 01_EN_3P372379 1C indd 2 7 9 2014 11 08 06 AM ECONO limiting the maximum power consumption It is useful when using theair conditioner and other electrical devic...

Page 124: ...repairing Using other refrigerants may cause trouble or damage to the unit and personal injury To avoid electric shocks do not operate with wet hands Beware of in case of refrigerant leakage If the air conditioner is not operating correctly i e not generating cool or warm air refrigerant leakage could be the cause Consult your dealer for assistance The refrigerant within the air conditioner is saf...

Page 125: ...nimals which can enter the unit Once inside the unit such animals can cause malfunctions smoke or if they come into contact with electrical parts Do not place objects around the indoor unit Doing so may have an adverse on the performance product quality and life of the air conditioner Installation site To install the air conditioner in the following types of environments consult your dealer Places...

Page 126: ...ration Panel tab Display ON OFF Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a short beep Operation start beep beep Settings changed beep Operation stop beeeeep Operation lamp green TIMER lamp orange INTELLIGENT EYE lamp green P Indoor Unit ON OFF switch Push this switch once to start operation Push once again to stop it The operation...

Page 127: ..._3P372379 1C indd 6 23 05 2015 18 56 08 AM Air outlet Air inlet back and side Refrigerant piping and inter unit wiring Model name plate Earth terminal inside Drain hose Outdoor temperature sensor back Titanium apatite photocatalytic air purifying filter with frame ...

Page 128: ...bout 7m FAN setting button Page 14 POWERFUL button POWERFUL operation Page 18 HEAT PUMPmodel ARC466A28 COOLING ONLY model ARC466A29 Display LCD Displays the current settings In this illustration each section is shown with all its displays on for the purpose of explanation TEMPERATURE adjustment button Changes the temperature setting Page 12 ON OFF button Press this button once to start operation P...

Page 129: ...button Cancels the timer setting Page 20 21 Cannot be used for the WEEKLY TIMER operation SELECT button Changes the clock ON OFF TIMER and WEEKLY TIMER settings ECONO QUIET button ECONO OUTDOOR UNIT QUIET operation Page 19 SWING button Page 13 WEEKLY button PROGRAMME button COPY button BACK button NEXT button WEEKLY TIMER operation Page 23 ON TIMER button Page 20 CLOCK button Page 10 01_EN_3P37237...

Page 130: ...sition Position and correctly 2 3 1 Remote controller holder Remote controller Screws NOTE Notes on batteries When replacing the batteries use batteries of the same type and replace both old batteries together The batteries will last for about 1 year If the remote controller display begins to fade and the possible transmission range becomes shorter within a year however replace both batteries with...

Page 131: ...ock 1 Press is displayed on the LCD and blink 2 Press to set the current day of the week 3 Press blinks 4 Press to set the clock to the present time Holding down or rapidly increases or decreases the displayed time 5 Press Point the remote controller at the indoor unit when pressing the buttons blinks 01_EN_3P372379 1C indd 10 7 9 2014 11 08 16 AM The remote controller may differ from some models ...

Page 132: ...ayed on the LCD The OPERATION lamp lights green To stop operation Press again disappears from the LCD The OPERATION lamp goes off AUTO DRY COOL HEAT FAN Operation NOTE Notes on AUTO operation In AUTO operation the system selects an appropriate operation mode COOL or HEAT based on the indoor temperature and starts the operation The system automatically reselects setting at a regular interval to bri...

Page 133: ...tting at a moderate level helps save energy Recommended temperature setting For cooling 26 0 28 0 C For heating 20 0 24 0 C Cover windows with a blind or a curtain Blocking sunlight and air from outdoors increases the cooling heating effect Page 31 If you are not going to use the air conditioner for a long period for example in spring or autumn turn off the circuit breaker The air conditioner alwa...

Page 134: ...ed To start auto swing Press is displayed on the LCD Press is displayed on the LCD The louvres vertical blades will begin to swing Press and and are displayed on the LCD or again s s e r P and reach the desired position or disappears from the LCD 01_EN_3P372379 1C indd 13 7 9 2014 11 08 19 AM ...

Page 135: ... quiet operation starts and noise from the indoor unit will become quieter AUTO COOL HEAT and FAN operation DRY operation changed NOTE throughout the room preventing areas of cold and hot developing 01_EN_3P372379 1C indd 14 7 9 2014 11 08 20 AM Movable range of the flap COOL DRY HEAT FAN ONLY ...

Page 136: ...ction while in HEAT operation which will provide a comfortable wind that will not come in direct contact with people To cancel COMFORT AIRFLOW operation To start COMFORT AIRFLOW operation Press Comfort is displayed on the LCD COOL and DRY operation HEAT operation FAN ONLY operation Flap direction Goes up Goes down Not available AUTO Press again disappears from the LCD Notes on COMFORT AIRFLOW Oper...

Page 137: ...isplayed on the LCD The INTELLIGENT EYE lamp lights green blank No Setting Intelligent eye The lamp lights when human movement is detected the unit automatically enters energy saving operation Do not place large objects near the INTELLIGENT EYE sensor Also keep heating units and humidifiers outside the sensor s detection area This sensor can detect undesirable objects Do not hit or violently push ...

Page 138: ...COMFORT AIRFLOW operation and INTELLIGENT EYE operation The rate will be set to AUTO If the up and down direction is selected COMFORT AIRFLOW operation will be canceled Priority is given to the function of whichever button is pressed last INTELLIGENT EYE operation is useful for energy saving People is detected in the sensing area No people are detected in the sensing area The air conditioner is in...

Page 139: ...in disappears from the LCD NOTE Notes on POWERFUL operation Pressing causes the settings to be cancelled and disappears from the LCD POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation In DRY operation In FAN operation Regarding the combination of POWERFUL and ...

Page 140: ...k No Setting Combination To cancel operation Press until no icon is displayed NOTE Notes on ECONO operation Pressing causes the settings to be cancelled and disappears from the LCD If the power consumption level is already low switching to ECONO operation will not reduce the power consumption Notes on OUTDOOR UNIT QUIET operation Even if the operation is stopped by using the remote controller or t...

Page 141: ...her button increases or decreases the time setting by 10 minutes Holding down either button changes the setting rapidly 3 Press again and setting time are displayed on the LCD The TIMER lamp lights orange Display To cancel ON TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off NOTE Notes on TIMER operation When TIMER is...

Page 142: ...ting rapidly 3 Press again and setting time are displayed on the LCD The TIMER lamp lights orange To cancel OFF TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining the 2 timers is shown below Example Present time 23 00 The unit operating OFF TIMER at 0 00 ...

Page 143: ...imer display mode cannot be changed while or are blinking Press or to stop the blinking Combining display modes Different display modes 24 HOUR ON OFF TIMER and COUNT UP DOWN ON OFF TIMER can be used for the ON TIMER and OFF TIMER simultaneously Example Present time 22 00 unit is in operation OFF TIMER at 1 00 3 hours after present time ON TIMER at 6 00 8 hours after present time Combined NOTE Not...

Page 144: ...to Friday because these settings are the same as those for Monday Page 26 6 00 8 30 17 30 22 00 25 0 C 27 0 C Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings for programmes 1 4 Page 24 8 00 10 00 19 00 21 00 27 0 C 27 0 C 25 0 C ON ON OFF OFF ON OFF OFF ON Programme 1 Programme 2 Programme 3 Programme 4 Up to 4 reservations per da...

Page 145: ...t day will be displayed 1 to 4 settings can be made per day 2 Press to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week 3 Press The day of the week and reservation number will be set and blink 4 Press to select the desired mode Pressing changes the or setting in sequence ON TIMER OFF TIMER blank No Setting In case the reserva...

Page 146: ... check for a receiving tone and blinking of the OPERATION lamp is displayed on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange A reservation made once can be easily copied and the same settings used for another day of the week Refer to Copy mode Page 26 NOTE Notes on WEEKLY TIMER operation Page 10 The day of the week ON OFF TIMER mode time and set temperature only for ...

Page 147: ...d day of the week will be copied 4 Press to select the destination day of the week 5 Press The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week will be copied To continue copying the settings to other days of the week repeat STEP 4 and STEP 5 6 Press to complete the setting is displayed on the LCD and WEEKLY TIMER operation is activat...

Page 148: ... mode Proceed to Setting mode STEP 4 Page 24 3 Press is displayed on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights orange To deactivate WEEKLY TIMER operation s s e r P while is displayed on the LCD disappears from the LCD The TIMER lamp goes off To reactivate the WEEKLY TIMER operation press again If a reservation deactivated with is activated once again the last reservati...

Page 149: ...The selected reservation will be deleted 6 Press If there are still other reservations WEEKLY TIMER operation will be activated Reservations for each day of the week This function can be used for deleting reservations for each day of the week 1 Press to select the day of the week to be deleted 2 Hold for about 5 seconds The reservation of the selected day of the week will be deleted All reservatio...

Page 150: ...ing do not use any of the following Water hotter than 40 0 C Volatile liquid such as benzene petrol and thinner Polishing compounds Rough materials such as a scrubbing brush Front panel Wipe it with a soft damp cloth If dirty Page 30 Once every 2 weeks Page 31 Indoor unit Outdoor unit and Remote controller Wipe them with a soft cloth If dirty Cleaning Replacement Once every 6 months Once every 3 y...

Page 151: ...d pull it toward you This will disconnect the front panel shaft on one side Disconnect the front panel shaft on the other side in the same manner 3 Clean the front panel Wipe it with a soft damp cloth Only neutral detergent may be used In case of washing the panel with water wipe it with a dry soft cloth and let it dry in the shade after washing 4 Attach the front panel Align the front panel shaft...

Page 152: ...le upwards then pull it down 3 water or clean them with a vacuum cleaner 2 weeks If the dust does not come off easily lukewarm water then let them dry in the shade Be sure to remove the titanium apatite photocatalytic Titanium apatite on the next page 4 5 Close the front panel slowly Page 30 2 Pull down 1 Push ...

Page 153: ...shake off remaining water and let them dry in the shade Replacement frame and attach a new one frame when replacing the titanium apatite properly set in thetabs 4 Set the titanium apatite photocatalytic air purifying 5 were Page 31 6 Close the front panel slowly Page 30 NOTE cannot deodorise the air cannot clean the air results in poor heating or cooling may cause odour the dealer where you bought...

Page 154: ...rom the remote controller We recommend periodical maintenance In certain operating conditions the inside of the air conditioner may get foul after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist in addition to regular cleaning by the user For specialist maintenance please contact the dealer where you bought the air conditioner T...

Page 155: ...ips immediately The air conditioner is adjusting the position of the flaps The flaps will start moving soon Different sounds are heard This sound is generated because the refrigerant in the air conditioner is This is a pumping sound of the water in the air conditioner and can be heard when the water is pumped out from the air conditioner during COOL or DRY operation The refrigerant in the air cond...

Page 156: ... operation and after turning off the circuit breaker remove the obstruction Then restart operation with the remote controller If the OPERATION lamp is still blinking check the error code and consult your dealer Page 38 The air conditioner does not stop operating Case Description what to check The air conditioner continues operating even after operation is stopped Immediately after the air conditio...

Page 157: ... to check The air conditioner gives off an odour We recommend you to have the indoor unit cleaned Please consult your dealer Others Case Description what to check The air conditioner suddenly starts behaving strangely during operation The air conditioner may malfunction due to lightning or radio If the air conditioner malfunctions turn off the power with the circuit breaker and restart the operati...

Page 158: ...e power cord is abnormally hot or damaged An abnormal sound is heard during operation The circuit breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn off the circuit breaker and call your dealer After a power failure The air conditioner automatically re...

Page 159: ...UTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARDFAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTROL IN COOLING H0 SENSOR FAULT H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR H8 DC CURRENT SENSOR FAULT H9 FAULTY SUCTION AIR TEMPERATURE SENSOR J3 FAULTY DISCHARGE PIP...

Page 160: ...3P372379 5D M15N076 1507 Quick Reference 00_CV_3P372379 1C indd 2 08 6 2015 AM MODE On Off FAN Temp Mode Swing ...

Reviews: