Outdoor Unit: RXS09/12LVJU
SiUS091133
261
Removal Procedure
4. Outdoor Unit: RXS09/12LVJU
4.1
Removal of Outer Panels / Fan Motor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Appearance features
Take care not to cut your finger
by the fins of the outdoor heat
exchanger.
2. Remove the panels.
When reassembling, make sure
to fit the 5 hooks.
1
Remove the screw of
the stop valve cover.
Pull the stop valve
cover downward and
remove it.
(R7186)
(R16044)
Stop valve
cover
Hook
(R16977)