background image

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

MODELS

FTXS25J2VMA
FTXS35J2VMA

00_CV_3P248412-1.indd   1

00_CV_3P248412-1.indd   1

6/1/2009   4:13:02 PM

6/1/2009   4:13:02 PM

Summary of Contents for FTXS25J2VMA

Page 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXS25J2VMA FTXS35J2VMA 00_CV_3P248412 1 indd 1 00_CV_3P248412 1 indd 1 6 1 2009 4 13 02 PM 6 1 2009 4 13 02 PM...

Page 2: ...the outdoor unit This function is useful when you need to consideration for your neighborhood Page 18 INTELLIGENT EYE The INTELLIGENT EYE sensor detects the human movement in a room If nobody in the r...

Page 3: ...ration 18 ECONO Operation 19 OFF TIMER Operation 20 ON TIMER Operation 21 WEEKLY TIMER Operation 22 Multi Connectio n Note for Multi System 28 Car e Care and Cleaning 30 Troubleshootin g Troubleshooti...

Page 4: ...ioner or otherwise fire may result Beware of fire in case of refrigerant leakage If the air conditioner is not operating correctly i e not generating cool or warm air refrigerant leakage could be the...

Page 5: ...r supplies other than the one specified may result in electric shocks overheating and fires Arrange the drain hose to ensure smooth drainage Imperfect drainage may cause wetting of the building furnit...

Page 6: ...ls from the remote controller When the unit receives a signal you will hear a beep sound Case Sound type Operation start beep beep Setting changed beep Operation stop long beep Display Indoor unit ON...

Page 7: ...ing and inter unit wiring Earth terminal It is inside of this cover Drain hose Air inlet back and side Air outlet Air filter Titanium apatite photocatalytic air purifying filter Outdoor temperature se...

Page 8: ...AN setting button It selects the airflow rate setting Page 14 POWERFUL button POWERFUL operation Page 17 Display LCD It displays the current settings In this illustration each section is shown with al...

Page 9: ...OFF TIMER and WEEKLY TIMER settings Page 20 21 22 QUIET button OUTDOOR UNIT QUIET operation Page 18 COMFORT SENSOR button COMFORT AIRFLOW and INTELLIGENT EYE operation Page 15 16 OFF TIMER button Pag...

Page 10: ...the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both 2 batteries with new size AAA LR03 alkaline The attached batteries...

Page 11: ...et the clock Press 1 is displayed and blinks Press 2 to set the current day of the week Press 3 blinks Press 4 to set the clock to the present time Holding down or button rapidly increases or decrease...

Page 12: ...rt of heating operation it takes some time before the room gets warmer In heating operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into def...

Page 13: ...W of electricity even while it is not operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off Use the air conditioner in the fo...

Page 14: ...g The 3 D airflow direction Press and and are displayed on the LCD The flaps and louvers move in turn To cancel 3 D airflow press either or again The flaps or louvers will stop moving To set the flaps...

Page 15: ...OMFORT AIRFLOW Stop operation Upper limit Lower limit Upper limit Lower limit Stop operation 8 15 50 80 30 70 8 80 Note on 3 D airflow Using 3 D airflow circulates cold air which tends to collected at...

Page 16: ...ople When nobody in the room 20 min after start energy saving operation The set temperature is shifted in 2 C steps Somebody back in the room Back to normal operation The air conditioner will return t...

Page 17: ...7m 55 Vertical angle 90 Side view Horizontal angle 110 Top view 7m Sensor may not detect moving objects further than 7m away Check the application range Sensor detection sensitivity changes according...

Page 18: ...TDOOR UNIT QUIET operation Priority is given to the function of whichever button is pressed last POWERFUL operation can only be set when the unit is running Pressing causes the settings to be canceled...

Page 19: ...unction will work only when the OUTDOOR UNIT QUIET operation is set on all operated indoor units However if using priority room setting refer to Note for multi system Page 28 This function is availabl...

Page 20: ...me Time Maximum during normal operation Maximum during ECONO Mode Normal operation ECONO Mode From start up until set temperature is reached Running current and power consumption This diagram is a rep...

Page 21: ...D The TIMER lamp lights up Display To cancel OFF TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off NOTE Notes on TIMER...

Page 22: ...time are displayed on the LCD The TIMER lamp lights up Display To cancel ON TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp go...

Page 23: ...age 25 6 00 8 30 17 30 22 00 25 C 27 C Program 1 Program 2 Program 3 Program 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings up to programs 1 4 Page 23 8 00 10 00 19 00 21 00 27...

Page 24: ...be displayed 1 to 4 settings can be made per day Press 2 to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week Press 3 The day o...

Page 25: ...cannot be used to go back to the reservation number 6 Press to select the desired time The time can be set between 0 00 and 23 50 in 10 minute intervals To return to the ON OFF TIMER mode setting pres...

Page 26: ...ill be copied Press 4 to select the destination day of the week Press 5 The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week will be cop...

Page 27: ...on number and press The mode is switched to setting mode Go to Setting mode STEP 4 Page 23 Press 3 to exit confirming mode is displayed on the LCD and WEEKLY TIMER operation is activated The TIMER lam...

Page 28: ...LY TIMER operation will be activated The reservations for each day of the week This function can be used for deleting reservations for each day of the week It can be used while conf irming or setting...

Page 29: ...tting active Refer to Priority room setting on the next page NIGHT QUIET mode Available only for COOL operation NIGHT QUIET mode requires initial programming during installation Please consult your re...

Page 30: ...in room B C and D Status of room B C and D when the unit in room A is in COOL mode COOL or DRY or FAN Current operation mode maintained HEAT The unit enters standby mode Operation resumes when the ro...

Page 31: ...he operation and turn the breaker off Do not touch the metal parts of the indoor unit If you touch those parts this may cause an injury Air filter Vacuum dust or wash filter Once every 2 weeks Refer t...

Page 32: ...e side Front panel shaft 1 Slide 2 Pull 1 Slide 2 Pull Disconnect the front panel shaft on the other side in the same manner Clean the front panel 2 Wipe it with a soft cloth soaked in water Only neut...

Page 33: ...cleaner It is recommended to clean the air filters every 2 weeks If the dust does not come off easily Wash the air filters with neutral detergent thinned with lukewarm water then dry them up in the s...

Page 34: ...tabs on the filter frame and replace with a new filter Do not throw away the filter frame Reuse the filter frame when replacing the titanium apatite photocatalytic air purifying filter Dispose of the...

Page 35: ...the service shop if this is the case Before a long idle period Operate the FAN only for several hours on a fine day to dry 1 out the inside Press and select operation Press and start operation After o...

Page 36: ...ted when the flow of the refrigerant in the air conditioner is switched over Pinging sound This sound is generated when the size of the air conditioner slightly expands or shrinks as a result of tempe...

Page 37: ...shes Are the air filters clean Is there anything to block the air inlet or the outlet of the indoor and the outdoor units Clean the air filters or take all obstacles away and turn the breaker off Then...

Page 38: ...es The ON OFF TIMER does not operate according to the settings Check if the ON OFF TIMER and the WEEKLY TIMER are set to the same time Change or deactivate the settings in the WEEKLY TIMER Page 22 The...

Page 39: ...r leaks from the indoor unit Turn the breaker off and call the service shop After a power failure The air conditioner automatically resumes operation in about 3 minutes You should just wait for a whil...

Page 40: ...3P248412 1 M08B287 0907 HT Two dimensional bar code is a code for manufacturing Quick Reference 00_CV_3P248412 1 indd 2 00_CV_3P248412 1 indd 2 6 1 2009 4 13 04 PM 6 1 2009 4 13 04 PM...

Reviews: