Page 1: ...DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FTXS80KVMA FTXS90KVMA FTXS100KVMA 00_CV_3P266961 1 fm Page 1 Monday April 19 2010 5 46 PM ...

Page 2: ...peration 10 Adjusting the Airflow Direction 12 COMFORT AIRFLOW Operation 14 INTELLIGENT EYE Operation 15 POWERFUL Operation 17 OUTDOOR UNIT QUIET Operation 18 ECONO Operation 19 TIMER Operation 20 WEEKLY TIMER Operation 22 CARE Care and Cleaning 27 TROUBLESHOOTING Troubleshooting 30 01_EN_3P266961 1 fm Page 1 Tuesday June 8 2010 2 36 PM ...

Page 3: ...or cooker may result in generation of noxious gas Do not longer use the air conditioner until a qualified service person confirms that the leakage has been repaired Do not attempt to install or repair the air conditioner yourself Improper workmanship may result in water leakage electric shocks or fire hazards Please contact your local dealer or qualified personnel for installation and maintenance ...

Page 4: ...ff or remove the power cord Otherwise an electric shock and injury may result Only connect the airconditioner to the specified powersupply circuit Power supplies otherthan the one specified may result in electric shocks overheatingand fires Arrange the drain hose to ensure smooth drainage Imperfect drainage may cause wetting of the building furniture etc Do not place objects in direct proximity of...

Page 5: ...4 Names of Parts Indoor Unit 1 2 16 13 12 14 15 8 4 3 10 11 9 7 6 5 01_EN_3P266961 1 fm Page 4 Tuesday June 8 2010 2 36 PM ...

Page 6: ...LIGENT EYE lamp green page 15 15 Indoor Unit ON OFF switch Push this switch once to start operation Push once again to stop it The operation mode refer to the following table This switch is useful when the remote controller is missing 16 Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a beep sound Operation start beep beep Settings chang...

Page 7: ...page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 18 9 ECONO button ECONO operation page 19 10 SWING button Flaps horizontal blades page 12 11 SWING button Louvers vertical blades page 12 12 COMFORT SENSOR button COMFORT AIRFLOW and INTELLIGENT EYE operation page 14 15 13 WEEKLY PROGRAM COPY BACK NEXT button WEEKLY TIMER operation page 22 14 SELECT button It changes the ON OFF TIMER and WEE...

Page 8: ...e system is not used for a long time take the batteries out The batteries will last for approx 1 year If the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both 2 batteries with new size AAA LR03 alkaline The attached batteries are provided for the initial use of the system The usable period of the batteries may be short d...

Page 9: ...o set the clock to the present time Holding down or button rapidly increases or decreases the time display 5 Press CLOCK button Point the remote controller at the indoor unit when pushing the buttons blinks NOTE If the indoor unit s internal clock is not set to the correct time ON OFF TIMER and WEEKLY TIMER will not operate punctually 1 3 5 2 4 01_EN_3P266961 1 fm Page 8 Tuesday June 8 2010 2 36 P...

Page 10: ... or autumn turn the breaker off Use the air conditioner in the following conditions The operation of the system outside the above humidity or temperature range may cause a safety device to disable the system Recommended temperature setting For cooling 26 C 28 C For heating 20 C 24 C Mode Operating conditions If operation is continued out of this range COOL Outdoor temperature 10 to 46 C Indoor tem...

Page 11: ... mode setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again disappears from the LCD The OPERATION lamp goes off To change the temperature setting 4 Press TEMPERATURE adjustment button DRY or FAN mode AUTO or COOL or HEAT mode The temperature setting is not variable Press to raise the temperature and press to lowe...

Page 12: ... During defrosting operation hot air does not flow out of indoor unit A pinging sound may be heard during defrosting operation which however does not mean that the air conditioner has failures Note on COOL operation This air conditioner cools the room by releasing the heat in the room outside Therefore the cooling performance of the air conditioner may be degraded if the outdoor temperature is hig...

Page 13: ...2 When the flaps have reached the desired position press SWING button once more The flaps will stop moving disappears from the LCD To adjust the louvers vertical blades 3 Press SWING button is displayed on the LCD 4 When the louvers have reached the desired position press the SWING button once more The louvers will stop moving disappears from the LCD 1 2 3 4 01_EN_3P266961 1 fm Page 12 Tuesday Jun...

Page 14: ...ates cold air which tends to collected at the bottom of the room and hot air which tends to collect near the ceiling throughout the room preventing areas of cold and hot developing ATTENTION Always use a remote controller to adjust the angles of the flaps and louvers If you attempt to move the flaps and louvers forcibly with hand when they are swinging the mechanism may be broken Always use a remo...

Page 15: ...NSOR button Press the button to select Blank Notes on COMFORT AIRFLOW operation The flap position will change preventing air from blowing directly on the occupants of the room POWERFUL operation and COMFORT AIRFLOW operation cannot be used at the same time The volume of air will be set to AUTO If the upward and downward airflow direction is selected the COMFORT AIRFLOW function will be canceled Pr...

Page 16: ...es are swinging the operating as above will stop the movement of them To cancel the INTELLIGENT EYE operation 2 Press COMFORT SENSOR button Press the button to select Blank EX 1 2 Blank Someone is back in the room Back to normal operation The air conditioner will return to normal operation when the sensor detects the movement of people again When someone is in the room Normal operation The air con...

Page 17: ...f passersby temperature range etc The sensor also mistakenly detects pets sunlight fluttering curtains and light reflected off of mirrors as passersby INTELLIGENT EYE operation will not go on during POWERFUL operation NIGHT SET MODE page 20 will not go on during use of INTELLIGENT EYE operation The air conditioner can go into operation with the COMFORT AIRFLOW and INTELLIGENT EYE functions combine...

Page 18: ...eration Priority is given to the function of whichever button is pressed last POWERFUL operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated I...

Page 19: ...UIET button again disappears from the LCD NOTE Notes on OUTDOOR UNIT QUIET operation This function is available in COOL HEAT and AUTO modes This is not available in FAN and DRY mode POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the same time Priority is given to the function of whichever button is pressed last OUTDOOR UNIT QUIET operation will drop neither the frequency nor...

Page 20: ... NOTE ECONO operation can only be set when the unit is running Pressing the OFF button causes the setting to be canceled and the disappears from the LCD ECONO operation is a function which enables efficient operation by limiting the power consumption of the outdoor unit operating frequency ECONO operation functions in AUTO COOL DRY and HEAT modes POWERFUL and ECONO operation cannot be used at the ...

Page 21: ...rapidly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel OFF TIMER operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the present time is not displayed Once you set ON OFF TIMER the time setting is kept in the memory The memory is canceled when remote controller batteries are replaced When operating the unit via the ON OFF TIMER the actual length of ope...

Page 22: ...pidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining the two timers is shown below ATTENTION In the following cases set the timer again After a breaker has turned off After a power failure After replacing batteries in the remote controller 1 3 4 2 Exam...

Page 23: ... of making reservations The use of ON ON ON ON settings for example makes it possible to schedule operating mode and set temperature changes Furthermore by using OFF OFF OFF OFF settings only the turn off time of each day can be set This will turn off the air conditioner automatically if the user forgets to turn it off Make timer settings up to programs 1 4 see page 23 Monday No timer settings Sat...

Page 24: ...r setting in sequence In case the reservation has already been set selecting blank deletes the reservation Go to STEP 9 if blank is selected 5 Press NEXT button The ON OFF TIMER mode will be set and the time blink 6 Press SELECT button to select the desired time The time can be set between 0 00 and 23 50 in 10 minute intervals To return to the ON OFF TIMER mode setting press BACK button Go to STEP...

Page 25: ...operation Do not forget to set the clock on the remote control first The day of the week ON OFF TIMER mode time and set temperature only for ON TIMER mode can be set with WEEKLY TIMER Other settings for ON TIMER are based on the settings just before the operation Both WEEKLY TIMER and ON OFF TIMER operation cannot be used at the same time The ON OFF TIMER operation has priority if it is set while ...

Page 26: ...the week repeat STEP 4 and STEP 5 6 Press button to complete the setting is displayed on the LCD and WEEKLY TIMER operation is activated NOTE Copy mode COPY MODE The entire reservation of the source day of the week is copied in the copy mode In the case of making a reservation change for any day of the week individually after copying the content of weekly reservations press button and change the s...

Page 27: ...button again If a reservation deactivated with WEEKLY button is activated once again the last reservation mode will be used To delete reservations Refer to page 23 When selecting desired mode at STEP 4 in setting mode select blank The reservation will be deleted This function can be used for deleting reservations for each day of the week 5 Press button 6 Select the day of the week to be canceled w...

Page 28: ...g 4 Attach the front panel Align the front panel shafts on the left and right of the front panel with the slots then push them all the way in Close the front panel slowly Press the panel at both sides and the center CAUTION Units Don t touch the metal parts of the indoor unit If you touch those parts this may cause an injury When removing or attaching the front panel use a robust and stable stool ...

Page 29: ...he shade It is recommended to clean the air filters every 2 weeks Titanium apatite photocatalytic air purifying filter The titanium apatite photocatalytic air purifying filter can be renewed by washing it with water once every 6 months We recommend replacing it once every 3 years Maintenance 1 Remove dust with a vacuum cleaner and wash lightly with water If it is very dirty soak it for 10 to 15 mi...

Page 30: ...apatite photocatalytic air purifying filter contact to the service shop there you bought the air conditioner Dispose of the old filter as non flammable waste Check that the base stand and other fittings of the outdoor unit are not decayed or corroded Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit Check that the drain comes smoothly out of the drain...

Page 31: ... after it has reached a certain temperature The HEAT operation stops suddenly and a flowing sound is heard The outdoor unit is taking away the frost The HEAT operation starts after the frost on the outdoor unit is removed You should wait for about 4 to 12 minutes The outdoor unit emits water or steam In HEAT mode The frost on the outdoor unit melts into water or steam when the air conditioner is i...

Page 32: ...Are batteries set in the remote controller Is the timer setting correct Cooling Heating effect is poor Are the air filters clean Is there anything to block the air inlet or the outlet of the indoor and the outdoor units Is the temperature setting appropriate Are the windows and doors closed Are the airflow rate and the air direction set appropriately Operation stops suddenly OPERATION lamp flashes...

Page 33: ...asons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenance contact the service shop where you bought the air conditioner The maintenance cost must be born by the user Call the service shop immediately After a power failure The air conditioner automatically resumes operation in about ...

Page 34: ... 1008 HT 3P266961 1 M09B395 Two dimensional barcodeisacode for manufacturing 00_CV_3P266961 1 fm Page 2 Monday April 19 2010 5 46 PM ...