8 Troubleshooting
Operation manual
14
FTXP20~35 ATXP20~35N5V1B9
R32 Split series
3P717028-5D – 2023.08
8.1.3
Symptom: A ticking sound is heard
This sound is generated when the unit slightly expands or contracts
with changes in temperature.
8.1.4
Symptom: A whistling sound is heard
This sound is generated by the refrigerant flowing during defrost
operation.
8.1.5
Symptom: A clicking sound during
operation or idle time is heard
This sound is generated when the refrigerant control valves or
electrical parts operate.
8.1.6
Symptom: A clapping sound is heard
This sound is generated when an external device sucks air out of the
room (e.g. exhaust fan, extractor hood) while the doors and windows
in the room are closed. Open the doors or windows, or turn off the
device.
8.1.7
Symptom: White mist comes out of a unit
(Indoor unit)
▪ When humidity is high during cooling operation (in oily and dusty
places). If the interior of an indoor unit is extremely contaminated,
the temperature distribution inside a room becomes uneven. It is
necessary to clean the interior of the indoor unit. Ask your dealer
for details on cleaning the unit. This operation requires a qualified
service person.
▪ When the air conditioner is changed over to heating operation
after defrost operation. Moisture generated by defrost becomes
steam and exits.
8.1.8
Symptom: The units can give off odours
The unit can absorb the smell of rooms, furniture, cigarettes, etc.,
and then emit it again.
8.1.9
Symptom: The outdoor fan rotates while
the air conditioner is not in operation
▪
After operation has stopped.
The outdoor fan continues to
rotate for another 30 seconds for system protection.
▪
While the air conditioner is not in operation.
When the outdoor
temperature is very high, the outdoor fan starts to rotate for
system protection.
8.2
Solving problems based on error
codes
Fault diagnosis by the wireless remote control
If the unit runs into a problem, you can identify the fault by checking
the error code by the wireless remote control. It is important to
understand the problem and take measures before resetting the
error code. This should be done by a licensed installer or your local
dealer.
INFORMATION
See the service manual for:
▪ The complete list of error codes
▪ A more detailed troubleshooting guideline for each
error
To check the error code by the wireless remote control
1
Aim the wireless remote control at the unit and press
for
about 5 seconds.
Result:
blinks in the temperature setting display section.
2
Aim the wireless remote control at the unit and press
repeatedly until a continuous beep is heard.
Result:
The code is now displayed on the display.
INFORMATION
▪ A short beep and 2 consecutive beeps indicate non-
corresponding codes.
▪ To cancel the code display, hold
for 5 seconds.
The code will also disappear from the display if the
button is NOT pressed within 1 minute.
System
Error code
Description
Normal
Refrigerant shortage
Overvoltage detection
Signal transmission error (between indoor and
outdoor unit)
Indoor/outdoor unit combination fault
Indoor unit
Error code
Description
Indoor unit PCB abnormality
Freeze-up protection or high-pressure control
Fan motor (DC motor) abnormality
Indoor heat exchanger thermistor abnormality
Room temperature thermistor abnormality
Outdoor unit
Error code
Description
4-way valve abnormality
Outdoor unit PCB abnormality
Overload activation (compressor overload)
Compressor lock
DC fan lock
Input power overcurrent
Discharge pipe temperature control
High-pressure control (in cooling mode)
Compressor system sensor abnormality
Position sensor abnormality
DC voltage / current sensor abnormality
Outdoor temperature thermistor abnormality
Discharge pipe thermistor abnormality
Outdoor heat exchanger thermistor abnormality
Electrical parts heat error
Radiation fin temperature rise
Inverter instantaneous overcurrent (DC)
Radiation fin thermistor abnormality
Compressor internal temperature error