Outdoor Unit
SiUS042113E
20
Part 3 Printed Circuit Board Connector Wiring Diagram
Caution
2. Outdoor Unit
2.1 09/12 class
Main PCB (A1P)
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
1)
S20
Connector for electronic expansion valve coil
2)
S40
Connector for overload protector
3)
S70
Connector for DC fan motor
4)
S80
Connector for four way valve
5)
S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge
pipe temperature)
6)
S97
Connector for liquid pipe thermistor
7)
HL1, HN1, S
Wire harness for terminal strip
8)
E1, E2
Wire harness for earth/ground wire
9)
U, V, W
Wire harness for compressor
10)
FU1, FU2
Fuse (3.15 A, 250 V)
11)
FU3
Fuse (30 A, 250 V)
12)
LEDA
LED for service monitor (green)
13)
V1, V2, V3
Varistor
14)
J4
Jumper for facility setting
Refer to page 153 for details.
15)
J9
Jumper for drain pan heater
Refer to page 154 for details.
2P628602-1
LEDA
FU1
FU3
FU2
S90
S40
S20
S70
V2
V3
V1
S80
S97
E2
E1
HN1
S
HL1
W
V
U
J9
J4
Summary of Contents for FTXM-V Series
Page 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Page 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Page 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Page 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Page 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...