Troubleshooting
SiUS042113E
96
Part 6 Service Diagnosis
4.6 Humidity Sensor Abnormality
Error Code
CC
Method of Error
Detection
Sensor abnormality is detected by input value.
Error Decision
Conditions
The communication error of humidity sensor or malfunction of humidity sensor.
Supposed
Causes
Disconnection of connector
Defective humidity sensor
Defective indoor unit PCB
Troubleshooting
R6000515
Correct the connection.
Replace the control PCB.
Completed.
Normal?
Caution
Be s
u
re to t
u
rn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Check the connection of
connectors.
NO
YES
* Connect the connector again for
ens
u
ring the connection.
Replace the h
u
midity sensor
PCB.
Error code displayed?
YES
NO