Daikin FTXF20A2V1B Operation Manual Download Page 4

3 Before operation

Operation manual

4

FTXF20~71A2V1B

Daikin room air conditioner

3P511999-3 – 2017.11

Icon

Description

Airflow rate = High

Airflow rate = Medium high

Airflow rate = Medium

Airflow rate = Medium low

Airflow rate = Low

Comfort operation is active

Auto vertical swing is active

ON timer is active

OFF timer is active

2.2.3

To operate the user interface

a

a

Signal receiver

1

Aim  the  signal  transmitter  at  the  signal  receiver  on  the  indoor
unit (maximum distance for communication is 7 m).

Result: 

When  the  indoor  unit  receives  a  signal  from  the  user

interface, you will hear a sound:

Sound

Description

Beep-beep

Operation starts.

Beep

Setting changes.

Long beep

Operation stops.

3

Before operation

3.1

To fix the user interface to the wall

b

c

a

a

User interface

b

Screw

c

User interface holder

1

Choose a place where the signals reach the unit.

2

Attach the holder with screws to the wall or a similar location.

3

Hang the user interface on the user interface holder.

3.2

To insert the batteries

The batteries will last for about 1 year.

1

Remove the back cover.

2

Insert both batteries at once.

3

Replace the back cover.

2

3

1

AAA.LR03

3.3

To turn on the power supply

1

Turn the circuit breaker on.

Result: 

The  flap  of  the  indoor  unit  will  open  and  close  to  set  the

reference position.

4

Operation

4.1

Operation range

Operation mode

Operation range

Cooling

(a)(b)

▪ Outdoor temperature: –10~46°C

▪ Indoor temperature: 18~32°C

▪ Indoor humidity: ≤80%

Heating

(a)

▪ Outdoor temperature: –15~24°C

▪ Indoor temperature: 10~30°C

Drying

(a)

▪ Outdoor temperature: –10~46°C

▪ Indoor temperature: 18~32°C

▪ Indoor humidity: ≤80%

If operated outside the operation range:

(a)

A safety device might stop the operation of the system.

(b)

Condensation might occur on the indoor unit and drip.

4.2

When to use which feature

You can use the following table to determine which features to use:

Feature

Tasks

Basic features

 Operation modes and

temperature

To start/stop the system and to set the
temperature:

▪ Heat up or cool down a room.

▪ Blow air in a room without heating or

cooling.

▪ Decrease the humidity in a room.

▪ In  Automatic  mode,  automatically

select  an  appropriate  temperature
and operation mode.

 Airflow direction

To adjust the airflow direction (swing or
fixed position).

 Airflow rate

To adjust the amount of air blown into
the room.

To run more quietly.

Summary of Contents for FTXF20A2V1B

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXF20A2V1B FTXF25A2V1B FTXF35A2V1B FTXF50A2V1B FTXF60A2V1B FTXF71A2V1B...

Page 2: ...t Please Keep the documentation for future reference Target audience End users INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or f...

Page 3: ...ed if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other appliances or contact your installer...

Page 4: ...the back cover 2 Insert both batteries at once 3 Replace the back cover 2 3 1 AAA LR03 3 3 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and cl...

Page 5: ...nfo Outside temperature The system s cooling or heating effect decreases when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor...

Page 6: ...operation This operation can be used in Heating or Cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people To start stop Comfort airflow operation I...

Page 7: ...imer lamp goes off INFORMATION Program the timer again in case of A breaker has turned the unit off A power failure After replacing batteries in the user interface To start stop OFF timer operation 1...

Page 8: ...ervice The installer has to perform a yearly maintenance About the refrigerant This product contains fluorinated greenhouse gases Do NOT vent gases into the atmosphere Refrigerant type R32 Global warm...

Page 9: ...erating the unit with dirty filters means that the filter CANNOT deodorize the air CANNOT clean the air poor heating cooling causes odour 6 5 To clean the air filters 1 Open the front panel 2 Push the...

Page 10: ...airflow rate setting Refer to 4 3 2 Airflow rate on page 5 Check the temperature setting Refer to 4 3 1 To start stop operation and to set the temperature on page 5 Check if the airflow direction sett...

Page 11: ...the service manual Fault diagnosis by user interface The user interface can receive an error code from the indoor unit referring to the fault It is important to understand the problem and take measur...

Page 12: ...3P511999 3 2017 11 Copyright 2017 Daikin...

Reviews: